Bosch Thermotechnology · Greenstar Wall (ZBR/ZWB)
Bosch Greenstar ZBR 21-3A
The Greenstar ZBR 21-3A is the smallest current wall-hung heating-only Greenstar boiler: 24,600 to 79,200 BTU/hr natural-gas input at 95% AFUE family rating (per Bosch CA marketing), 103.6 lb in the shared 440 x 850 x 353 mm wall cabinet.
Key figures
- Max input
- 79.2 MBH
- Max CSA output
- 74.7 MBH
- AFUE
- —
- Min input
- 24.6 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Bosch Greenstar ZBR 21-3A in practice
The ZBR 21-3A is the entry point of Bosch's current wall-hung Greenstar line, a heating-only condensing boiler whose manual technical table lists 79,200 BTU/hr maximum and 24,600 BTU/hr minimum input on natural gas (LPG ratings appear after conversion with the included kit). It shares the 440 x 850 x 353 mm cabinet and 103.6 lb (47 kg) shipping weight of the whole wall family and produces no domestic hot water itself — hot water comes from an indirect tank on the system.
Bosch's Canadian pages market the Greenstar family at 95% AFUE with a 'fully-modulating fan' and an aluminum-silicon alloy heat exchanger; the I&O manual itself prints the input/output tables and notes max supply temperature 187 °F and 30 psi maximum heating pressure. The 21-3A vents as a Category IV direct-vent appliance: 2" pipe is natural gas only, and 3" or the 3"/5" concentric system is required for propane.
The Heatronic control shows two-character fault codes from the manual's display-fault table (for example E9 for a tripped safety high limit or flue gas temperature limiter, and EA for no flame detected). Fault-code meaning and reset behaviour should be read against the 11.2025 Wall I&O manual.
Best suited to
- Small homes and suites whose heat-loss calculation fits under 79 MBH of input
- Projects replacing a wall-hung boiler on the 440 x 850 x 353 mm footprint
- Heating-only systems that keep domestic hot water on a separate indirect tank
Applicability and support
- Model number
- ZBR 21-3A
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Bosch Thermotechnology. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input rate, minimum | 24.6 MBH | 24,600 BTU/hr at 180/79 °F (82/26 °C), natural gas. |
| Input rate, maximum | 79.2 MBH | 79,200 BTU/hr at 180/79 °F (82/26 °C), natural gas; altitude tables in the manual reduce the maximum above 2,000 ft. |
| Output | ||
| Output rate, maximum (104/86 °F) | 74.7 MBH | 74,700 BTU/hr at 104/86 °F water temperatures per the manual technical table. |
| Venting and air | ||
| Venting | 2" NG only; 3" or 3"/5" (80/125 mm) concentric for LPG | Per the manual: the 21/28 model class runs up to 52 ft of straight 2" concentric pipe with 2 elbows (NG), or 50 ft of 3"/5" concentric pipe with 1 elbow. |
| Physical and connections | ||
| Weight (without packaging) | 103.6 lb | 103.6 lb (47 kg) without packaging per the manual. |
| Dimensions (W x H x D) | 17-21/64" × 33-15/32" × 13-57/64" (440 × 850 × 353 mm) | Per the manual technical data table. |
| Sound pressure level | ≤ 39 dB(A) | Per the manual technical data table. |
| Maximum supply temperature | 187 °F | 187 °F (86 °C). |
| Maximum permissible operating pressure (PMS), heating | 30 psi | 30 psi (2.07 bar). |
| Nominal water capacity (heating) | 0.925 gal | 0.925 gal (3.5 l). |
| Permissible inlet gas pressure | NG 3.5–10.5 in. W.C.; LPG 8–13 in. W.C. | NG is the factory default; LPG only after successful gas conversion with the included conversion kit. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Separate NG and LPG ratings in the manual; LPG requires the gas conversion kit included with the appliance. |
Frequently asked questions
Is the ZBR 21-3A a combi boiler?
No. The ZBR codes are heating-only wall models; domestic hot water is produced by an indirect tank or separate appliance. Bosch's wall-hung combis carry ZWB codes.
How much does the ZBR 21-3A weigh?
103.6 lb (47 kg) without packaging, per the technical data table of the 11.2025 I&O manual.
Can the ZBR 21-3A run on propane?
Yes, after gas conversion. The manual states LPG is permissible only after successful gas conversion with the kit included with the appliance, and it prints separate LPG ratings.
Questions about the Bosch Greenstar ZBR 21-3A?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Bosch Home Comfort Canada — Greenstar Boilers · accessed September 7, 2026
- Greenstar Wall Boilers Installation and Service Manual (6721853955) · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.