Gas boiler and hydronics glossary

108 terms used by technicians, manuals and regulators — defined in plain language, grouped by topic, and linked to the page on this site that puts each one to work.

On this page

Definitions describe general gas-boiler and hydronic practice. Where a term is set by regulation, the official source is cited and linked. Manufacturer-specific values live on the model pages with their own sources — see how Boilers.ca verifies data. Looking for a fault rather than a term? Start with the error code database.

Glossary · 1 of 8

Efficiency, output and ratings

How boiler performance is measured, and why a rating on a brochure is not the same as the performance of an installed system.

AFUE

Annual Fuel Utilization Efficiency — the seasonal efficiency rating Canada's Energy Efficiency Regulations apply to household gas boilers. Natural Resources Canada sets a minimum of 90% AFUE for hot-water boilers and 82% for low-pressure steam boilers, with no continuously burning pilot light.

Condensing boiler buying guide · Condensing boilers · Source: Natural Resources Canada — Gas boilers, household (Energy Efficiency Regulations)

Thermal efficiency

The share of the fuel's energy that reaches the water under steady-state test conditions, expressed as a percentage. It is a lab number at one operating point, not a season-long average like AFUE.

Brand specifications

Combustion efficiency

A figure calculated from flue-gas temperature and oxygen or CO2 content, printed by a combustion analyser during commissioning and service. It describes how completely the burner burns gas, not how much heat the building receives.

Boiler maintenance

Steady-state efficiency

Efficiency measured with the burner running continuously and temperatures stabilised. Real installations spend much of their time at part load, so a steady-state figure flatters seasonal performance.

Seasonal efficiency

Efficiency averaged across a heating season, including part-load operation, cycling and standby losses. AFUE is the seasonal metric used in Canadian household boiler regulation.

Source: Natural Resources Canada — Guide to Canada's Energy Efficiency Regulations

Gross output vs net output

Gross output is the heat the boiler delivers at its outlet; net output subtracts an allowance for piping and pick-up losses, historically used for steam ratings. Compare gross with gross and net with net, and check which basis a spec sheet uses.

Modulation

A burner that varies its gas input continuously between a minimum and a maximum to match the building's load, instead of firing on and off. Modulation is what lets a condensing boiler stay in its efficient low-fire range.

Condensing boilers · Short cycling

Turndown ratio

Maximum input divided by minimum input — a 10:1 boiler can fire down to one-tenth of its rated input. A higher turndown keeps the boiler at low fire longer, which reduces cycling in mild weather.

Commercial and modular plants

Minimum fire (low fire)

The lowest stable input a modulating burner can hold. Below it the flame becomes unstable, so the control either cycles the burner or shuts it down.

Combustion fan

Condensing

Recovering heat from flue-gas water vapour by cooling the gas below its dew point, which requires return water cool enough for condensation to actually happen. A condensing boiler that runs hot simply does not condense and behaves like a conventional one.

Condensing boilers · Condensing boiler buying guide

Sensible heat

Heat that changes a substance's temperature without changing its phase — the heat transferred to the water in the boiler. It is the only heat an older non-condensing boiler recovers.

Condensing boilers

Latent heat

Heat released when water vapour condenses into liquid, recovered by a condensing heat exchanger. It is the extra energy that makes condensing boilers more efficient than conventional ones.

Condensing boilers

Dew point (flue gas)

The temperature at which water vapour in the flue gas starts to condense. Condensing performance depends on keeping the heat-exchanger surface below that point, which is a system-design question.

Condensing boilers

Low-NOx

A burner design that produces fewer nitrogen oxides, typically through premix combustion and lower flame temperatures. Boilers.ca reports NOx figures only when a manufacturer publishes them for the model.

Brand specifications

NOx class

An emission band some manufacturers cite for low-emission burners, common in European standards. It is separate from Canada's federal boiler efficiency requirements, which are set in AFUE terms.

Source: Natural Resources Canada — Gas boilers, household (Energy Efficiency Regulations)

SEER equivalent for boilers

SEER and SEER2 rate cooling equipment; the comparable efficiency metric for a gas boiler is AFUE. There is no SEER rating for a boiler, so comparisons should stay in AFUE terms.

Boiler vs heat pump

Water content

The volume of water the boiler's heat exchanger holds. Low-water-content boilers respond quickly and suit modulating operation; older cast-iron boilers hold far more water, which buffers cycling but wastes energy warming up mass.

Floor-standing boilers · Non-condensing boilers

Glossary · 2 of 8

Sizing and heat loss

The calculation that decides how big a boiler should be, and the failure modes that follow when it is done badly.

Heat loss

The rate at which a building loses heat to outdoors at a chosen indoor-outdoor temperature difference, calculated room by room from surfaces, insulation values and air leakage. It is the number a boiler is sized from.

Heat-loss assessment · Sizing and heat loss guide

Design temperature

The outdoor temperature a heat-loss calculation assumes for the coldest day of the year at a location. The milder the climate, the lower the calculated loss — which is why rules of thumb borrowed from colder regions oversize coastal BC boilers.

Sizing and heat loss guide

Sizing

Choosing a boiler whose output matches the calculated heat loss plus any domestic-hot-water load, while keeping the boiler in its modulating range on typical days. Sizing is not the same as picking a model by floor area.

Boiler sizing service · Sizing and heat loss guide

Manual J equivalent

Manual J is the Air Conditioning Contractors of America's residential load-calculation method, widely referenced in North America. In Canada the comparable calculation is CSA F280; either way, boiler size comes from a room-by-room load calculation, not from the old boiler's rating.

Sizing and heat loss guide · Source: ACCA — Manual J residential load calculation

Oversizing

Installing a boiler with more output than the building needs. An oversized modulating boiler reaches minimum fire quickly and starts cycling; an oversized non-condensing boiler short-cycles even harder.

Short cycling · Sizing and heat loss guide

Short cycling

Frequent burner starts and stops before the system reaches steady operation, usually caused by oversizing, a thermostat problem, a stuck zone valve or low flow. Cycling wastes fuel, wears ignition components and stops condensing boilers from condensing.

Short cycling problem page

Glossary · 3 of 8

Boiler types and construction

The main designs you will see in Canadian homes and mechanical rooms, and the vocabulary used to describe them.

Fire-tube

A boiler design in which hot combustion gases pass through tubes surrounded by water. Fire-tube boilers hold a large water volume and are common in older low-pressure steam and commercial heating plants.

Fire-tube boiler design

Water-tube

A design in which water passes through tubes heated by the flame and gases, so the water volume is smaller and the response faster. Many modern wall-hung condensing boilers use a water-tube-style heat exchanger.

Water-tube boiler design

Cast-iron boiler

A sectional boiler made of cast-iron sections, usually non-condensing, with a large water content and a long service life. Cast iron is why old floor-standing boilers can survive decades, and why they resist low-temperature condensing operation.

Floor-standing boilers · Non-condensing boilers

Condensing boiler

A boiler designed to recover latent heat from flue gas, usually with a stainless or aluminium heat exchanger and sealed plastic venting. To actually condense it must run with cool return water, which is a system-design question as much as a boiler choice.

Condensing boilers

Non-condensing boiler

A conventional boiler that keeps flue gases above their dew point to protect the heat exchanger and vent from acidic condensate. Atmospheric and most cast-iron boilers fall in this group.

Non-condensing boilers

Combi boiler

A single appliance that heats the hydronic loop and makes domestic hot water on demand through a plate heat exchanger, with no storage tank. Compact and tank-free, its hot-water limit is the burner's continuous delivery rate.

Combi boilers · Combi vs system boiler

System boiler

A heating-only boiler paired with a separate indirect storage tank, with the pump and expansion vessel usually built into the boiler. It stores hot water rather than making it on demand.

System boilers · Combi vs system boiler

Heat-only boiler

A boiler that supplies space heating only and relies on a separate appliance — typically an indirect tank heated by the boiler — for domestic hot water. Also called a heating-only boiler.

System boilers · Indirect tank vs tankless

Wall-hung boiler

A boiler that mounts on a wall, usually condensing and often a combi or system unit, saving floor space. Installation depends on the wall's construction and the manufacturer's clearance requirements.

Wall-hung boilers

Floor-standing boiler

A boiler that stands on the floor, historically cast-iron and non-condensing, still common in older homes and larger plants. Modern floor-standing condensing models exist for higher outputs.

Floor-standing boilers

Steam boiler

A boiler that boils water to make low-pressure steam, which moves through pipes to radiators and returns as condensate. Steam systems need water-level controls and different maintenance from hot-water systems.

Gas-fired steam boilers

Cascade

Two or more boilers piped and controlled as one plant, firing in sequence to match load. Cascading extends turndown at the plant level and gives redundancy if one boiler stops.

Commercial and modular plants · Cascade communication fault

Modular boiler plant

A plant built from several smaller boilers instead of one large one, so the plant tracks the load closely and one boiler's failure does not stop heating. Common in commercial and strata buildings.

Commercial and modular plants

Staging

Bringing boilers or burner stages on and off in steps as load changes, rather than modulating one burner. Staging is normal in multi-boiler plants and in older equipment.

Commercial and modular plants

Glossary · 4 of 8

Hydronics and the water side

The parts, piping and water conditions that move heat from the boiler to the rooms.

Hydronic heating

Heating that distributes heat with water through pipes to radiators, baseboards, fan coils or in-floor loops. The boiler's job is to supply the loop at the temperature the emitters need.

System boilers · In-floor radiant guide

Primary/secondary loop

A piping arrangement that separates the boiler loop (primary) from the distribution loops (secondary) with closely spaced tees or a hydraulic separator, so flow in one loop does not force flow in the other. It protects boiler flow and decouples pressure between loops.

Hydraulic separator · Buffer tank

ΔT (delta-T)

The temperature difference between supply and return water, or across a heat exchanger. ΔT tells the technician how much heat the system is actually moving: at a given flow, a small ΔT means little heat is being delivered.

Hydronic zoning and balancing

Head pressure

The pressure a circulator must develop to push water through the loop, created by friction in pipes, fittings and components, and expressed as head (feet or metres). The system's head at design flow decides which pump curve fits.

Circulator pump

Circulator pump

The pump that moves water through the boiler and heating loop. Modern high-efficiency circulators vary their speed to hold a flow or pressure setpoint instead of running at one speed.

Circulator pump

Air separator

A device that removes entrained air from system water, usually combined with an automatic air vent. Air left in the loop causes noise, corrosion and cold spots.

Air separator · Automatic air vent · Air in radiators

Expansion tank

A tank that absorbs the volume increase as water heats, keeping system pressure stable. A failed or waterlogged tank shows up as pressure swings or a discharging relief valve.

Expansion tank · Boiler losing pressure

Low-water cutoff

A safety control that shuts the burner down if the water level in the boiler falls too low, protecting the heat exchanger from overheating. It is standard on steam boilers and common on larger hot-water plants.

Low-water cutoff

Zone valve

A motorised valve that opens or closes a heating zone on a thermostat's call, so each area gets heat only when it asks. A stuck zone valve causes a cold zone or a boiler that runs without heating anything.

Zone valve · Zone valve stuck · Cold heating zones

TRV (thermostatic radiator valve)

A valve that throttles flow through an individual radiator based on room temperature. TRVs balance rooms within a zone but are not a substitute for proper system balancing.

Thermostatic radiator valves

Aquastat

A temperature controller that switches the burner or circulator based on boiler water temperature. On older boilers it sets the high and low limits; on modern condensing boilers its role is usually taken by the control board and sensors.

Aquastat

Indirect DHW

Domestic hot water heated by the boiler through a coil or heat exchanger inside an insulated storage tank, so the boiler never touches potable water. It stores hot water rather than producing it on demand.

Indirect tank vs tankless · Indirect tank sizing

Plate heat exchanger

A stack of corrugated plates that transfers heat between two fluids in a very small volume; combi boilers use one to heat domestic water, and some systems use one to separate the boiler from the loop. Its narrow passages make water quality and dirt separation important.

Plate heat exchanger · DHW plate heat exchanger

Diverter valve

A valve that switches a combi boiler's output between space heating and domestic hot water. When it sticks, the boiler may heat radiators when a tap opens — or give no hot water at all.

Diverting valve · Combi hot water fluctuating

Buffer tank

A water tank added to a hydronic system to add thermal mass, reducing short cycling on small zones or with low-water-content boilers. It stores heating energy, not domestic hot water.

Buffer tank

Hydraulic separator

A vessel that decouples primary and secondary loops, allowing different flows on each side while sharing heat. It replaces closely spaced tees in tighter installations.

Hydraulic separator

Balancing valve

A valve used to adjust flow through a circuit so all zones heat evenly. Balancing is a commissioning step, not a repair.

Balancing valve · Hydronic zoning and balancing

Outdoor reset

A control strategy that lowers the boiler's supply temperature as outdoor temperature rises, matching heat output to load. It is what keeps a condensing boiler returning cool water long enough to condense.

Outdoor reset sensor · Boiler controls

System feeder (make-up water)

A valve or feeder that adds water to the loop to maintain pressure. It should add water rarely: a system that needs constant make-up is leaking or has a failed component.

System feeder · Boiler losing pressure

Pressure relief valve

A safety valve that opens at its rated pressure to protect the boiler and loop from overpressure. A relief valve that keeps discharging points to an expansion or pressure problem, not a bad valve.

Pressure relief valve · Relief valve discharging

Water treatment (inhibitor)

Chemicals and practices that keep hydronic water from corroding metals or depositing scale, including inhibitors and, in some systems, glycol. Manufacturers' instructions and local water chemistry decide what a loop needs.

Hydronic water treatment · Hydronic flushing guide

Kettling

A rumbling or banging sound from the boiler as water boils or steam pockets form on a hot heat-exchanger surface, often linked to scale, sludge or low flow. It is a symptom to diagnose, not something to silence by turning the temperature down.

Kettling and rumbling noises · Boiler noise diagnosis

Air lock

An air pocket that stops water from circulating through part of the system, leaving zones cold even though the boiler runs. Bleeding and proper air separation clear it.

Air in radiators

Glossary · 5 of 8

Gas, ignition and combustion

The gas-side components and measurements behind a safe, stable flame. Gas-side work in British Columbia is regulated work.

Gas valve

The valve that opens and regulates gas flow to the burner under the control board's command. It is a gas-side component: testing and replacement are licensed gas work.

Gas valve

Orifice

A precisely sized opening that meters gas into a burner or pilot. Orifices differ for natural gas and propane, and a wrong orifice changes combustion and safety.

Gas orifice

Venturi

A narrowing passage that uses the pressure drop of moving air to draw gas into the air stream for premixing, common in modulating condensing burners. Its geometry sets the air-gas ratio at a given fan speed.

Combustion fan

Premix burner

A burner that mixes gas and air before combustion, usually with a metal-fibre or mesh surface, giving low emissions and stable modulation. Premix burners are typical of modern condensing boilers.

Burner assembly

Burner assembly

The parts that introduce and burn the gas-air mixture, including the burner head, gaskets and often the fan and venturi on premix designs. Seals and correct reassembly matter for combustion safety.

Burner assembly

Ignition electrode

An electrode that creates the spark to light the burner, or senses flame on some designs. A cracked or fouled electrode causes ignition faults even when gas and air are correct.

Ignition electrode · Ignition failure

Hot-surface igniter

A ceramic element that glows to light the burner instead of a spark. It is fragile, and a failed one produces an ignition lockout.

Hot-surface igniter

Flame sensor

A rod or electrode that proves the flame to the control board by sensing the tiny current that flows through a flame. A dirty or eroded sensor lets the burner light and then drop out — a common lights-then-locks-out fault.

Flame sensor

Flame rectification

The principle behind flame sensing: the control applies a voltage to the flame rod, and the flame conducts a small rectified current back. No current means no proven flame, and the gas valve closes.

Flame sensor

Gas pressure

The pressure of the gas supply at the appliance inlet, checked against the manufacturer's requirement during installation and service. Incorrect inlet pressure changes input and combustion, so it is measured, not guessed.

Boiler diagnostics

Manifold pressure

The gas pressure downstream of the gas valve, set to the manufacturer's specification for the appliance. It is verified with a manometer and is one of the checks behind a proper combustion analysis.

Boiler maintenance

Gas train

The assembly of gas-side components — valve, regulator, pressure switches and manifold — that controls gas to the burner. Work on the gas train is licensed gas work.

Gas valve

Combustion analysis

Measuring flue-gas oxygen or CO2, temperature and carbon monoxide to verify the burner is adjusted correctly. It is part of commissioning and annual maintenance, and the evidence that a repair is complete.

Boiler maintenance · Boiler commissioning

Glossary · 6 of 8

Controls, sensors and diagnostics

The electronics that run the boiler, the sensors they read, and the language they use when something is wrong.

Control board

The circuit board that runs the boiler's sequence: it reads sensors, opens the gas valve, drives the fan and reports codes. Many apparent sensor faults are actually wiring or board faults, which is why diagnosis comes before parts.

Control board

Thermistor

A temperature sensor whose electrical resistance changes with temperature; boilers use them for supply, return, flue and outdoor readings. An open or shorted thermistor produces a specific fault code and can stop the boiler.

Thermistor · Boiler sensors

Sensor open or short

A fault condition where the control sees a sensor circuit outside its plausible range — a broken wire reads as open, crossed wires as short. The control locks out rather than run with bad temperature data.

Thermistor

Error code

A code or message the boiler displays to identify a fault condition. The same code can mean different things on different controllers, which is why Boilers.ca ties each code to a documented scope.

Error code database · What error codes mean

Fault code

Another name for an error code, common on European equipment and in manufacturer manuals. Always read it with the model and controller in hand.

Error code database

Blocking error

A condition that temporarily prevents the boiler from firing without locking it out — waiting for a pump run-on, a sensor to cool or a pressure switch to reset. A blocking error clears itself when the condition does; a lockout does not.

What error codes mean

Lockout

A safety state in which the control has stopped the burner and will not restart without an action — waiting for the fault to clear or a manual reset. Never reset repeatedly: a lockout is the boiler reporting a fault.

What error codes mean · Boiler repair

Soft lockout

A lockout that the control will clear and retry by itself after a delay, provided the fault has gone away. If the fault repeats, the boiler typically escalates to a hard lockout.

What error codes mean

Hard lockout

A lockout that requires a manual reset — often a button or power cycle — before the boiler will try again. Repeated hard lockouts indicate a fault that needs diagnosis.

What error codes mean · Display locked or unresponsive

E00-style code

A placeholder for display codes such as E00, E01 or F2. A code like E00 is not universal: on one controller it can be a sensor fault and on another a fan fault, so it must be read against the exact brand, series, controller and manual version.

Error code database · What error codes mean

Reset

Clearing a lockout to allow another ignition attempt, done once per the manual when it is safe. Resetting repeatedly hides the fault and can delay a repair while components wear.

Boiler repair

Zone control panel

The panel of relays and transformers that connects thermostats to zone valves and circulators and sends heat calls to the boiler. Loose wiring or a failed relay shows up as a zone that never calls or a boiler that never gets the call.

Zone control panel

Glossary · 7 of 8

Venting, air and condensate

How flue gases leave the building, how combustion air arrives, and how the water that condensing produces is handled.

Direct vent

A venting arrangement that takes combustion air from outdoors through a dedicated intake and exhausts flue gases outdoors, sealing the combustion path from the room. Direct-vent installations do not use indoor air for combustion.

Boiler venting · Boiler venting explained

Sealed combustion

Combustion in a closed path with outdoor air and outdoor exhaust, so the appliance does not depressurise the home or draw pollutants into it. Modern condensing boilers are sealed-combustion appliances.

Boiler venting

Category I–IV venting

The NFPA/ANSI venting categories: I is non-condensing negative-pressure, II condensing negative-pressure, III non-condensing positive-pressure, IV condensing positive-pressure. Condensing boilers are typically Category IV and need certified plastic venting.

Boiler venting explained · Boiler venting

Concentric vent

A two-pipe-in-one terminal where flue exhaust runs inside and combustion air outside, or the reverse, giving one wall penetration. The manufacturer's kit and clearance rules apply.

Concentric vent kit

ULC S636

The Canadian standard for plastic gas venting systems, required by CSA B149.1 for the certified plastic pipe condensing boilers use. Uncertified or mixed-brand venting is a safety failure, not a shortcut.

Boiler venting explained · Source: Technical Safety BC — directive: plastic venting

Flue

The passage that carries combustion products from the burner to outdoors, including the vent connector, pipe and terminal. Flue routing, length and termination are set by the manufacturer's tables.

Boiler venting

Combustion air

The air a burner needs to burn gas safely, supplied either from outdoors through a sealed intake or, on older equipment, from the room. Starving a burner of air produces carbon monoxide.

Boiler venting

Condensate trap

A water seal at the boiler's condensate outlet that lets acidic water drain while keeping flue gases inside the vent. A blocked or dry trap stops the boiler or leaks flue gas.

Condensate trap · Blocked condensate line

Condensate neutralizer

A container of alkaline media that raises the pH of acidic condensate before it reaches the drain, where local rules require treatment. The media is consumed and must be replenished.

Condensate neutralizer

Condensate pump

A small pump that lifts condensate to a drain when gravity drainage is not possible. A failed pump backs water up into the boiler and triggers a fault.

Condensate pump

Flue gas recirculation

Flue products drawn back into the burner or intake instead of exhausting, which can happen with poor vent design or wind effects and disturbs combustion. It is one reason vent termination clearances matter.

Boiler venting

Glossary · 8 of 8

Codes, standards, licensing and permits

The rules and authorities behind gas boiler work in British Columbia, and the terms that appear on certificates, permits and rating plates.

ASME

The American Society of Mechanical Engineers, publisher of the Boiler and Pressure Vessel Code; Section IV covers heating boilers. ASME codes govern the construction of many commercial and steam boilers, while Canadian installations also follow CSA B149.1 and provincial rules.

How Boilers.ca verifies data · Source: ASME — find codes and standards

CSA/ANSI Z21.13

The harmonized CSA/ANSI safety standard for gas-fired central heating boilers, often printed as Z21.13 / CSA 4.9 on manufacturer spec sheets and certification marks. It covers construction and performance of the appliance itself.

How Boilers.ca verifies data

CSA B149.1

The Natural Gas and Propane Installation Code adopted in BC, covering installation, venting and gas piping requirements. BC gas contractors are required to maintain current code books.

Boiler permits in BC · Source: Technical Safety BC — Gas licences

TSBC (Technical Safety BC)

The provincial safety regulator that licenses gas contractors and gas fitters, issues permits, and enforces the Safety Standards Act and Gas Safety Regulation. Its public registry lets anyone check a contractor's licence.

Boiler permits in BC · Source: Technical Safety BC — Gas licences

Gas contractor licence

A licence issued by Technical Safety BC to a business that performs regulated gas work. In BC, gas work must be done by a licensed contractor's licensed fitters, under permit, with the contractor responsible for compliance.

About Boilers.ca · How Boilers.ca verifies data · Source: Technical Safety BC — Gas licences

Gas fitter Class A

A BC certificate of qualification that allows the holder to perform installations and alterations on any gas system except vehicle fuel systems, under permit, plus certain restricted electrical work. Since 2023 it is a Red Seal trade in BC.

Source: Technical Safety BC — Class A gas fitter

Gas fitter Class B

A BC certificate of qualification that allows installations and alterations on appliances of 120 kW input or less, plus piping and vents, under permit, with limited electrical work. Since 2025 it is a Red Seal trade in BC.

Source: Technical Safety BC — Class B gas fitter

Permit (gas permit)

Authorization from the regulator to perform regulated work, required for installing or replacing a gas boiler in BC. The permit ties the work to an inspection and a Notification of Completion.

Boiler permits in BC · Source: Technical Safety BC — Gas installation permits

Notification of Completion

A form the licensed contractor submits to Technical Safety BC when regulated work is finished, so the installation can be reviewed or inspected. It is part of closing out a boiler installation.

Source: Technical Safety BC — Gas licences

Commissioning

The documented process of verifying a new or repaired boiler against the manufacturer's instructions: combustion analysis, gas pressure, flow, controls and safety checks, with results recorded. ROMA commissions installations and provides the record.

Boiler commissioning

Certification mark

A mark on the appliance showing it is certified to the applicable standard for sale and installation in Canada. Installing an uncertified appliance is prohibited, and inspectors look for the mark.

How Boilers.ca verifies data · Source: Technical Safety BC — Gas licences

Boiler plant classification

Technical Safety BC's classification of boiler plants by type and pressure for operating-permit purposes. Classification determines inspection and operator requirements for larger plants.

Source: Technical Safety BC — boiler plant classification

Sources

Official sources used in this glossary

Regulator, standards-body and code sources cited above, each checked September 9, 2026. Manufacturer-specific figures are never stated here — they live on the model pages with their own citations.

Not sure what the boiler is telling you?

Describe the symptom or the display text — ROMA Heating & Cooling diagnoses it and does the work across Greater Vancouver.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

CallEmailEstimate