CurrentCanadian status unknown
- Input
- 9–80 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CO-90 is Dunkirk's 90 MBH-class wall-hung residential combi: 9 to 80 MBH central-heating input with DHW input from 9 to 90 MBH (2.5 GPM at a 70 °F rise), 95.2% AFUE, 74 MBH heating capacity and up to 10:1 turndown.
Natural gasPropaneCombi
CurrentCanadian status unknown
- Input
- 15–120 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CO-150 is Dunkirk's 150 MBH-class wall-hung residential combi: 15 to 120 MBH central-heating input with DHW input from 15 to 150 MBH (3.7 GPM at a 70 °F rise), 95.2% AFUE, 110 MBH heating capacity and up to 10:1 turndown.
Natural gasPropaneCombi
CurrentCanadian status unknown
- Input
- 20–180 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CO-200 is Dunkirk's 200 MBH-class wall-hung residential combi: 20 to 180 MBH central-heating input with DHW input from 20 to 200 MBH (5.1 GPM at a 70 °F rise), 95.2% AFUE, 167 MBH heating capacity and up to 10:1 turndown.
Natural gasPropaneCombi
CurrentCanadian status unknown
- Input
- 8–80 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CH-80 is Dunkirk's 80 MBH-class wall-hung residential heating-only boiler: 8 to 80 MBH central-heating input at 95.2% AFUE with 74 MBH heating capacity, a 64 MBH net AHRI water rating and up to 10:1 turndown.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 10–100 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CH-100 is Dunkirk's 100 MBH-class wall-hung residential heating-only boiler: 10 to 100 MBH central-heating input at 95.2% AFUE with 92 MBH heating capacity, a 80 MBH net AHRI water rating and up to 10:1 turndown.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 12–120 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CH-120 is Dunkirk's 120 MBH-class wall-hung residential heating-only boiler: 12 to 120 MBH central-heating input at 95.2% AFUE with 110 MBH heating capacity, a 96 MBH net AHRI water rating and up to 10:1 turndown.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CH-150 is Dunkirk's 150 MBH-class wall-hung residential heating-only boiler: 15 to 150 MBH central-heating input at 95.2% AFUE with 139 MBH heating capacity, a 121 MBH net AHRI water rating and up to 10:1 turndown.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 18–180 MBH
- Output (max)
- —
- AFUE
- 95.2 %
The Royal CH-180 is Dunkirk's 180 MBH-class wall-hung residential heating-only boiler: 18 to 180 MBH central-heating input at 95.2% AFUE with 165 MBH heating capacity, a 143 MBH net AHRI water rating and up to 10:1 turndown.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 16.6–93.5 MBH
- Output (max)
- —
- AFUE
- 95 %
The Dunkirk DCC-115 is the 115.5 MBH-class combi of the DCC 'AI' condensing line: 16.6 to 93.5 MBH central-heating input with DHW input to 115.5 MBH (2.5 GPM at a 70 °F rise), 95% AFUE and 85.4 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).
Natural gasPropaneCombi
DiscontinuedCanadian status unknown
- Input
- 22–125 MBH
- Output (max)
- —
- AFUE
- 95 %
The Dunkirk DCC-150 is the 153 MBH-class combi of the DCC 'AI' condensing line: 22 to 125 MBH central-heating input with DHW input to 153 MBH (3.5 GPM at a 70 °F rise), 95% AFUE and 113 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).
Natural gasPropaneCombi
DiscontinuedCanadian status unknown
- Input
- 29.5–164 MBH
- Output (max)
- —
- AFUE
- 95 %
The Dunkirk DCC-205 is the 205 MBH-class combi of the DCC 'AI' condensing line: 29.5 to 164 MBH central-heating input with DHW input to 205 MBH (5 GPM at a 70 °F rise), 95% AFUE and 153 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).
Natural gasPropaneCombi
DiscontinuedCanadian status unknown
- Input
- 16.6–75 MBH
- Output (max)
- —
- AFUE
- 92 %
The Dunkirk DCB-75 is the 75 MBH-class central-heating model of the DCB 'AI' condensing line: 16.6 to 75 MBH input at 92% AFUE with 68.2 MBH heating capacity and a 60 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 16.6–93.5 MBH
- Output (max)
- —
- AFUE
- 95 %
The Dunkirk DCB-100 is the 93.5 MBH-class central-heating model of the DCB 'AI' condensing line: 16.6 to 93.5 MBH input at 95% AFUE with 85.4 MBH heating capacity and a 74 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 22–125 MBH
- Output (max)
- —
- AFUE
- 95 %
The Dunkirk DCB-125 is the 125 MBH-class central-heating model of the DCB 'AI' condensing line: 22 to 125 MBH input at 95% AFUE with 113 MBH heating capacity and a 98 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 29.5–164 MBH
- Output (max)
- —
- AFUE
- 95 %
The Dunkirk DCB-165 is the 164 MBH-class central-heating model of the DCB 'AI' condensing line: 29.5 to 164 MBH input at 95% AFUE with 153 MBH heating capacity and a 133 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 36–241 MBH
- Output (max)
- —
- AFUE
- 95 %
The Dunkirk DMG-240 is the wall-hung condensing boiler of the DMG pair — positioned 'Residential/Light Commercial' on the official page: 36 to 241 MBH input, 216 MBH heating capacity, 95% AFUE (ENERGY STAR), 6.7:1 turndown and a 50 psi ASME rating, with an optional floor base kit.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 35–379 MBH
- Output (max)
- —
- AFUE
- —
The Dunkirk DMG-380 is the floor-standing condensing boiler of the DMG pair — a 'Commercial Offering' per the official page: 35 to 379 MBH input, 348 MBH heating capacity, 95% thermal efficiency, 10.5:1 turndown and an 80 psi ASME rating.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk WPSB-3D is a current atmospheric cast-iron gas water boiler: 75 MBH natural-gas input (propane 70 MBH) for 63 MBH heating capacity and a 55 MBH net AHRI water rating at 84% AFUE, with 6.3 gallons of water content and a Fuel Smart Hydrostat control.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk WPSB-4D is a current atmospheric cast-iron gas water boiler: 112.5 MBH natural-gas input (propane 105 MBH) for 94 MBH heating capacity and a 82 MBH net AHRI water rating at 84% AFUE, with 8.1 gallons of water content and a Fuel Smart Hydrostat control.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84.1 %
The Dunkirk WPSB-5D is a current atmospheric cast-iron gas water boiler: 150 MBH natural-gas input (propane 140 MBH) for 126 MBH heating capacity and a 110 MBH net AHRI water rating at 84.1% AFUE, with 9.9 gallons of water content and a Fuel Smart Hydrostat control.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84.1 %
The Dunkirk WPSB-6D is a current atmospheric cast-iron gas water boiler: 187.5 MBH natural-gas input (propane 175 MBH) for 157 MBH heating capacity and a 137 MBH net AHRI water rating at 84.1% AFUE, with 11.7 gallons of water content and a Fuel Smart Hydrostat control.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk WPSB-7D is a current atmospheric cast-iron gas water boiler: 225 MBH natural-gas input (propane 210 MBH) for 188 MBH heating capacity and a 163 MBH net AHRI water rating at 84% AFUE, with 13.5 gallons of water content and a Fuel Smart Hydrostat control.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk WPSB-8D is a current atmospheric cast-iron gas water boiler: 262 MBH natural-gas input (propane 245 MBH) for 221 MBH heating capacity and a 191 MBH net AHRI water rating at 84% AFUE, with 15.3 gallons of water content and a Fuel Smart Hydrostat control.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk WPSB-9D is a current atmospheric cast-iron gas water boiler: 299 MBH natural-gas input (propane 280 MBH) for 252 MBH heating capacity and a 218 MBH net AHRI water rating at 84% AFUE, with 17.2 gallons of water content and a Fuel Smart Hydrostat control.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk DXL-060K is a current cast-iron gas water boiler on the Hydrolevel w-4200 control: 59 MBH input for 50 MBH heating capacity and a 43 MBH net AHRI water rating at 84% AFUE, with 1.9 gallons of water content, a 4" flue and 2 burners at 215 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk DXL-095K is a current cast-iron gas water boiler on the Hydrolevel w-4200 control: 90.8 MBH input for 76.3 MBH heating capacity and a 66 MBH net AHRI water rating at 84% AFUE, with 2.3 gallons of water content, a 5" flue and 3 burners at 250 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk DXL-120K is a current cast-iron gas water boiler on the Hydrolevel w-4200 control: 120 MBH input for 101 MBH heating capacity and a 88 MBH net AHRI water rating at 84% AFUE, with 2.8 gallons of water content, a 6" flue and 4 burners at 295 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk DXL-150K is a current cast-iron gas water boiler on the Hydrolevel w-4200 control: 149 MBH input for 125 MBH heating capacity and a 109 MBH net AHRI water rating at 84% AFUE, with 3.2 gallons of water content, a 6" flue and 5 burners at 335 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk DXL-175K is a current cast-iron gas water boiler on the Hydrolevel w-4200 control: 175 MBH input for 147 MBH heating capacity and a 128 MBH net AHRI water rating at 84% AFUE, with 3.7 gallons of water content, a 7" flue and 6 burners at 385 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk DXL-205K is a current cast-iron gas water boiler on the Hydrolevel w-4200 control: 205 MBH input for 172 MBH heating capacity and a 150 MBH net AHRI water rating at 84% AFUE, with 4.1 gallons of water content, a 7" flue and 7 burners at 420 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk DXL-235K is a current cast-iron gas water boiler on the Hydrolevel w-4200 control: 235 MBH input for 197 MBH heating capacity and a 171 MBH net AHRI water rating at 84% AFUE, with 4.6 gallons of water content, a 7" flue and 8 burners at 465 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84.4 %
The Dunkirk XEB-2 is a current induced-draft cast-iron gas water boiler: 42.5 MBH input for 36 MBH heating capacity and a 31 MBH net AHRI water rating at 84.4% AFUE, with 1.75 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 225 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk XEB-3 is a current induced-draft cast-iron gas water boiler: 75 MBH input for 63 MBH heating capacity and a 55 MBH net AHRI water rating at 84% AFUE, with 3 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 265 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk XEB-4 is a current induced-draft cast-iron gas water boiler: 112.5 MBH input for 95 MBH heating capacity and a 82 MBH net AHRI water rating at 84% AFUE, with 4.25 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 322 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk XEB-5 is a current induced-draft cast-iron gas water boiler: 150 MBH input for 127 MBH heating capacity and a 109 MBH net AHRI water rating at 84% AFUE, with 5.5 gallons of water content, a 4" chimney / 3" side wall vent option and a Honeywell recessed control at 370 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Dunkirk XEB-6 is a current induced-draft cast-iron gas water boiler: 187.5 MBH input for 158 MBH heating capacity and a 135 MBH net AHRI water rating at 84% AFUE, with 6.75 gallons of water content, a 4" chimney / 4" side wall vent option and a Honeywell recessed control at 431 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.7 %
The Dunkirk PSB-3D is a current cast-iron gas steam boiler: 75 MBH natural-gas input (70 MBH propane) for 62/58 MBH NG/LP heating capacity, a 47/44 MBH net AHRI steam rating (195/183 sq ft) at 82.7% AFUE, with a 5" flue and 297 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Dunkirk PSB-4D is a current cast-iron gas steam boiler: 112 MBH natural-gas input (105 MBH propane) for 91/85 MBH NG/LP heating capacity, a 68/64 MBH net AHRI steam rating (283/267 sq ft) at 82% AFUE, with a 6" flue and 368 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Dunkirk PSB-5D is a current cast-iron gas steam boiler: 150 MBH natural-gas input (140 MBH propane) for 122/114 MBH NG/LP heating capacity, a 92/86 MBH net AHRI steam rating (383/358 sq ft) at 82% AFUE, with a 6" flue and 440 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Dunkirk PSB-6D is a current cast-iron gas steam boiler: 187 MBH natural-gas input (175 MBH propane) for 153/143 MBH NG/LP heating capacity, a 115/107 MBH net AHRI steam rating (479/446 sq ft) at 82% AFUE, with a 7" flue and 512 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Dunkirk PSB-7D is a current cast-iron gas steam boiler: 225 MBH natural-gas input (210 MBH propane) for 183/171 MBH NG/LP heating capacity, a 137/128 MBH net AHRI steam rating (570/533 sq ft) at 82% AFUE, with a 7" flue and 584 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Dunkirk PSB-8D is a current cast-iron gas steam boiler: 262 MBH natural-gas input (245 MBH propane) for 214/200 MBH NG/LP heating capacity, a 161/150 MBH net AHRI steam rating (670/625 sq ft) at 82% AFUE, with a 7" flue and 659 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Dunkirk PSB-9D is a current cast-iron gas steam boiler: 299 MBH natural-gas input (280 MBH propane) for 245/229 MBH NG/LP heating capacity, a 184/172 MBH net AHRI steam rating (766/717 sq ft) at 82% AFUE, with a 7" flue and 736 lb shipping.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 90 %
The Dunkirk Q90-50 is a legacy condensing cast-aluminium gas boiler: 50 MBH input for 45 MBH heating capacity and a 39 MBH net I=B=R rating at 90% AFUE, with a 2" flue arrangement and 220 lb shipping.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 90 %
The Dunkirk Q90-75 is a legacy condensing cast-aluminium gas boiler: 75 MBH input for 68 MBH heating capacity and a 59 MBH net I=B=R rating at 90% AFUE, with a 2" flue arrangement and 220 lb shipping.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 90 %
The Dunkirk Q90-100 is a legacy condensing cast-aluminium gas boiler: 100 MBH input for 90 MBH heating capacity and a 78 MBH net I=B=R rating at 90% AFUE, with a 2" flue arrangement and 220 lb shipping.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 90 %
The Dunkirk Q90-125 is a legacy condensing cast-aluminium gas boiler: 125 MBH input for 112.5 MBH heating capacity and a 98 MBH net I=B=R rating at 90% AFUE, with a 2" CPVC & 3" PVC flue arrangement and 284 lb shipping.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 90 %
The Dunkirk Q90-150 is a legacy condensing cast-aluminium gas boiler: 150 MBH input for 135 MBH heating capacity and a 117 MBH net I=B=R rating at 90% AFUE, with a 2" CPVC & 3" PVC flue arrangement and 284 lb shipping.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 90 %
The Dunkirk Q90-175 is a legacy condensing cast-aluminium gas boiler: 175 MBH input for 157.5 MBH heating capacity and a 137 MBH net I=B=R rating at 90% AFUE, with a 2" CPVC & 3" PVC flue arrangement and 284 lb shipping.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 90 %
The Dunkirk Q90-200 is a legacy condensing cast-aluminium gas boiler: 200 MBH input for 180 MBH heating capacity and a 157 MBH net I=B=R rating at 90% AFUE, with a 2" CPVC & 3" PVC flue arrangement and 284 lb shipping.
Natural gasPropaneHeating-only