Skip to content
Boilers.caby ROMA Heating & Cooling

Brand hub

Fulton boilers in Canada

Fulton (Fulton Thermal Corporation, Pulaski, New York, established 1949) is an American boiler manufacturer whose current hydronic gas lines are the ENDURA family of condensing firetube boilers — ENDURA, ENDURA+, ENDURA XE — plus the dual-fuel VANTAGE.

Canadian status unknownHQ: Pulaski, New York

At a glance

Official site
Global site
Country
United States
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Documented series
5
Documented models
16

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

About Fulton

Fulton is an American boiler manufacturer established in 1949 and based in Pulaski, New York (Fulton Thermal Corporation / Fulton Group). Its current condensing hydronic gas boiler lines are the ENDURA family — ENDURA (750,000–2,000,000 BTU/hr), ENDURA+ (2,500,000–12,000,000 BTU/hr) and ENDURA XE (399,000–6,000,000 BTU/hr) — plus the VANTAGE dual-fuel condensing boiler (2,000,000–6,000,000 BTU/hr with #2 oil back-up).

The non-condensing hydronic side includes the CLASSIC vertical tubeless hot-water boiler (ICW, 6–30 BHP) and the VMPW vertical multi-port hot-water boiler (40–150 BHP, efficiencies up to 84%), with electric hydronic lines (ENDURA ZE, ENDURA LB) sitting outside this gas hub's scope.

Fulton's official rep finder lists both United States and Canada as selectable countries, but no explicit per-product 'available in Canada' statement was found, so canadianStatus is recorded as unknown. Fulton's product pages publish public brochure, I&O and specification documents.

Series

Fulton boiler series

Each series hub lists its models, verified specifications, manuals and documented alerts.

  • ENDURA

    current

    The ENDURA is Fulton's condensing duplex-stainless firetube boiler in four sizes — EDR-750, EDR-1000, EDR-1500 and EDR-2000 (750,000–2,000,000 BTU/hr) — with a fully-wetted 3-pass design, variable primary flow and low NOx under 20 ppm.

    condensingNatural gasPropane

    4 models, specs and manuals →

  • ENDURA+

    current

    The ENDURA+ is Fulton's larger condensing firetube boiler: 2,500,000–12,000,000 BTU/hr in models EDR+2500 through EDR+12000, with a patent-pending stress reliever, variable primary flow, up to 15:1 turndown with O2 compensation, and knockdown capability on models up to 6 million BTU/hr.

    condensingNatural gasPropane

    0 models, specs and manuals →

  • ENDURA XE

    current

    The ENDURA XE is Fulton's condensing firetube hydronic boiler in twelve sizes from EXE-399 to EXE-6000 (399,000–6,000,000 BTU/hr) with Flame-by-Wire combustion, real-time O2 compensation, efficiency up to 99% and 8:1–15:1 turndown.

    condensingNatural gasPropane99% thermal-efficiency

    0 models, specs and manuals →

  • VANTAGE

    current

    The VANTAGE is Fulton's dual-fuel condensing firetube hydronic boiler — natural gas or propane with #2 oil back-up — in models VTG-2000 through VTG-6000 (2,000,000–6,000,000 BTU/hr), built on a high-mass duplex-stainless vessel with a lifetime thermal-shock warranty.

    condensingNatural gasPropane

    5 models, specs and manuals →

  • The Pulse (PHW) is Fulton's gas pulse-combustion hydronic heating boiler, documented from PHW-300 through PHW-2000 (plus the PHW-2000LE low-emission variant) in official product data submittals and an I&O manual that remain in Fulton's document library without a current catalogue page.

    unknownNatural gas

    7 models, specs and manuals →

Models

Fulton models with verified specifications

CurrentCanadian status unknown
Input
90000–750000 BTU/h
Output (max)
728,250 BTU/h
AFUE
—

The Fulton ENDURA EDR-750 is a condensing duplex-stainless firetube commercial hydronic boiler rated 750,000 BTU/hr input and 728,250 BTU/hr output at 97.1% thermal efficiency, with 8:1 turndown per the official Endura TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
90000–1000000 BTU/h
Output (max)
953,000 BTU/h
AFUE
—

The Fulton ENDURA EDR-1000 is a condensing duplex-stainless firetube commercial hydronic boiler rated 1,000,000 BTU/hr input and 953,000 BTU/hr output at 95.3% thermal efficiency, with 11:1 turndown per the official Endura TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
133000–1500000 BTU/h
Output (max)
1,402,500 BTU/h
AFUE
—

The Fulton ENDURA EDR-1500 is a condensing duplex-stainless firetube commercial hydronic boiler rated 1,500,000 BTU/hr input and 1,402,500 BTU/hr output at 93.5% thermal efficiency, with 11:1 turndown per the official Endura TDS.

Natural gasHeating-only
CurrentCanadian status unknown
Input
133000–2000000 BTU/h
Output (max)
1,874,000 BTU/h
AFUE
—

The Fulton ENDURA EDR-2000 is a condensing duplex-stainless firetube commercial hydronic boiler rated 2,000,000 BTU/hr input and 1,874,000 BTU/hr output at 93.7% thermal efficiency, with 15:1 turndown per the official Endura TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
1,918,000 BTU/h
AFUE
—

The Fulton VANTAGE VTG-2000 is a condensing firetube commercial hydronic boiler rated 2,000,000 BTU/hr input and 1,918,000 BTU/hr output at 95.7% thermal efficiency, with up to 5:1 natural-gas turndown per the official Vantage TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
2,889,000 BTU/h
AFUE
—

The Fulton VANTAGE VTG-3000 is a condensing firetube commercial hydronic boiler rated 3,000,000 BTU/hr input and 2,889,000 BTU/hr output at 96.3% thermal efficiency, with up to 5:1 natural-gas turndown per the official Vantage TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
3,876,000 BTU/h
AFUE
—

The Fulton VANTAGE VTG-4000 is a condensing firetube commercial hydronic boiler rated 4,000,000 BTU/hr input and 3,876,000 BTU/hr output at 96.9% thermal efficiency, with up to 5:1 natural-gas turndown per the official Vantage TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
4,630,000 BTU/h
AFUE
—

The Fulton VANTAGE VTG-5000 is a condensing firetube commercial hydronic boiler rated 5,000,000 BTU/hr input and 4,630,000 BTU/hr output at 92.6% thermal efficiency, with up to 5:1 natural-gas turndown per the official Vantage TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
5,640,000 BTU/h
AFUE
—

The Fulton VANTAGE VTG-6000 is a condensing firetube commercial hydronic boiler rated 6,000,000 BTU/hr input and 5,640,000 BTU/hr output at 94% thermal efficiency, with up to 5:1 natural-gas turndown per the official Vantage TDS.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
270,000 BTU/h
AFUE
—

The Fulton Pulse PHW-300 is a gas pulse-combustion commercial hydronic boiler rated 300,000 BTU/hr input and 270,000 BTU/hr output at 8 BHP, documented by Fulton's public PHW product data submittal and I&O manual.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
440,000 BTU/h
AFUE
—

The Fulton Pulse PHW-500 is a gas pulse-combustion commercial hydronic boiler rated 500,000 BTU/hr input and 440,000 BTU/hr output at 13 BHP, documented by Fulton's public PHW product data submittal and I&O manual.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
637,500 BTU/h
AFUE
—

The Fulton Pulse PHW-750 is a gas pulse-combustion commercial hydronic boiler rated 750,000 BTU/hr input and 637,500 BTU/hr output at 19 BHP, documented by Fulton's public PHW product data submittal and I&O manual.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
840,000 BTU/h
AFUE
—

The Fulton Pulse PHW-1000 is a gas pulse-combustion commercial hydronic boiler rated 1,000,000 BTU/hr input and 840,000 BTU/hr output at 25 BHP, documented by Fulton's public PHW product data submittal and I&O manual.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
1,204,000 BTU/h
AFUE
—

The Fulton Pulse PHW-1400 is a gas pulse-combustion commercial hydronic boiler rated 1,400,000 BTU/hr input and 1,204,000 BTU/hr output at 36 BHP, documented by Fulton's public PHW product data submittal and I&O manual.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
1,700,000 BTU/h
AFUE
—

The Fulton Pulse PHW-2000 is a gas pulse-combustion commercial hydronic boiler rated 2,000,000 BTU/hr input and 1,700,000 BTU/hr output at 50 BHP, documented by Fulton's public PHW product data submittal and I&O manual.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
—
Output (max)
1,700,000 BTU/h
AFUE
—

The Fulton Pulse PHW-2000LE is a gas pulse-combustion commercial hydronic boiler rated 2,000,000 BTU/hr input and 1,700,000 BTU/hr output at 50 BHP, documented by Fulton's public PHW product data submittal and I&O manual.

Natural gasHeating-only

Services

ROMA services for Fulton boilers

On-site service in Greater Vancouver. Brand and model context is kept when you request service.

Error codes and alerts

Fulton error codes

Documented meanings resolved against the specific series, controller and manual version. A code is not a diagnosis.

No codes documented yet.

Full Fulton error-code index →

Frequently asked questions

Where is Fulton based?

Fulton (Fulton Thermal Corporation) is based in Pulaski, New York, and was established in 1949, per its official site.

Is Fulton available in Canada?

Fulton's official rep finder offers 'United States | Canada' country selection, but no explicit per-product Canadian statement was found on the captured product pages, so Boilers.ca records canadianStatus as unknown.

Which Fulton lines does Boilers.ca document?

The condensing hydronic gas hubs: ENDURA, ENDURA+ and ENDURA XE, plus the dual-fuel VANTAGE. The CLASSIC and VMPW hot-water lines are mentioned as non-condensing context.

Need help with a Fulton boiler?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate