- Input
- 15–60 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP060160C is the smallest I-Series+ combi: 15 to 60 MBH central-heating input with DHW input to 160 MBH and 7.9 GPM maximum hot-water flow in one wall-hung condensing appliance, rated up to 96% AFUE in Rinnai's Canadian marketing.
Natural gasPropaneCombi
- Input
- 15–90 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP090099C is the I-Series+ combi with the closest CH/DHW pair: 15 to 90 MBH heating input and a 99 MBH DHW input (5.3 GPM maximum flow), rated up to 96% AFUE in Rinnai's Canadian marketing.
Natural gasPropaneCombi
- Input
- 15–90 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP090199C pairs a 90 MBH heating input with a 199 MBH DHW input: 15 to 90 MBH central heating plus near-tankless hot-water headroom in the small 73 lb chassis, rated up to 96% AFUE in Rinnai's Canadian marketing.
Natural gasPropaneCombi
- Input
- 15–120 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP120199C lifts heating to 120 MBH of input while keeping the 199 MBH DHW side: 15 to 120 MBH central heating with 9.8 GPM maximum hot-water flow, in the heavier 76.1 lb small chassis.
Natural gasPropaneCombi
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP150199C is the top of the fully documented I-Series+ combi range: 15 to 150 MBH central-heating input with a 199 MBH DHW side (9.8 GPM maximum), the largest small-chassis combi at 76.1 lb.
Natural gasPropaneCombi
- Input
- 15–60 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP060S is the smallest I-Series+ solo: a heating-only condensing boiler firing 15 to 60 MBH of input with no built-in hot-water production, documented from the solo I&O manual 800000191(02) at 62.6 lb.
Natural gasPropaneHeating-only
- Input
- 15–90 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP090S is the mid-size I-Series+ solo: a heating-only condensing boiler firing 15 to 90 MBH of input at the same 62.6 lb and small-chassis footprint as the IP060S, with hot water via an indirect tank.
Natural gasPropaneHeating-only
- Input
- 15–120 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP120S steps the heating-only solo line up to 120 MBH of input (15-120 MBH) on the 10.9 sq ft heat exchanger at 64.8 lb per the manual, with hot water handled by an indirect tank.
Natural gasPropaneHeating-only
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP150S is the largest fully documented I-Series+ solo: a heating-only condensing boiler firing 15 to 150 MBH of input at 64.8 lb per the manual, controlling an indirect tank for domestic hot water.
Natural gasPropaneHeating-only
- Input
- 15–175 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP175199C is the 175k I-Series+ combi — 175 MBH of central-heating input with a 199 MBH DHW side on the large chassis, documented from the EN 175k+ combi I&O manual at 123.5 lb. It is named in Health Canada recall RA-77507.
Natural gasPropaneCombi
- Input
- 15–199 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP199199C is the top I-Series+ combi — 199 MBH of central-heating input with a 199 MBH DHW side on the large chassis, documented from the EN 175k+ combi I&O manual at 123.5 lb. It is named in Health Canada recall RA-77507.
Natural gasPropaneCombi
- Input
- 15–175 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP175S is the 175k heating-only I-Series+ solo on the large chassis, marketed on rinnai.ca as available since September 2024 and documented on Boilers.ca from the EN I&O manual (doc 800000216) at 112.4 lb. It is named in Health Canada recall RA-77507.
Natural gasPropaneHeating-only
- Input
- 15–199 MBH
- Output (max)
- —
- AFUE
- 96 %
The Rinnai IP199S is the top heating-only I-Series+ solo at 199 MBH of central-heating input on the large chassis, documented on Boilers.ca from the EN I&O manual (doc 800000216) at 112.4 lb. It is named in Health Canada recall RA-77507.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai i060CN is a legacy Canadian I-Series combi boiler — a 60 MBH central-heating input rating per the page copy with a 15 MBH minimum fire and an unlabelled 160 MBH maximum bullet — wall-hung and condensing, documented from its orphaned rinnai.ca page as discontinued history.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai i090CN is a legacy Canadian I-Series combi boiler — a 90 MBH central-heating input rating per the page copy with a 15 MBH minimum fire and an unlabelled 160 MBH maximum bullet — wall-hung and condensing, documented from its orphaned rinnai.ca page as discontinued history.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai i120CN is a legacy Canadian I-Series combi boiler — a 120 MBH central-heating input rating per the page copy with a 15 MBH minimum fire and an unlabelled 199 MBH maximum bullet — wall-hung and condensing, documented from its orphaned rinnai.ca page as discontinued history.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai i060SN is a legacy Canadian I-Series heating-only solo boiler — a 60 MBH central-heating input rating per the page copy with a 15 MBH minimum fire and a truncated 'N (maximum)' bullet (page bug) — wall-hung and condensing, documented from its orphaned rinnai.ca page as discontinued history.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai i090SN is a legacy Canadian I-Series heating-only solo boiler — a 90 MBH central-heating input rating per the page copy with a 15 MBH minimum fire and a truncated 'N (maximum)' bullet (page bug) — wall-hung and condensing, documented from its orphaned rinnai.ca page as discontinued history.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai i120SN is a legacy Canadian I-Series heating-only solo boiler — a 120 MBH central-heating input rating per the page copy with a 15 MBH minimum fire and a truncated 'N (maximum)' bullet (page bug) — wall-hung and condensing, documented from its orphaned rinnai.ca page as discontinued history.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai i150SN is a legacy Canadian I-Series heating-only solo boiler — a 150 MBH central-heating input rating per the page copy with a 15 MBH minimum fire and a truncated 'N (maximum)' bullet (page bug) — wall-hung and condensing, documented from its orphaned rinnai.ca page as discontinued history.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M060CN is a discontinued Canadian M-Series combi boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M090CN is a discontinued Canadian M-Series combi boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M120CN is a discontinued Canadian M-Series combi boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M160CN is a discontinued Canadian M-Series combi boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M060SN is a discontinued Canadian M-Series heating-only solo boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M090SN is a discontinued Canadian M-Series heating-only solo boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M120SN is a discontinued Canadian M-Series heating-only solo boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Rinnai M160SN is a discontinued Canadian M-Series heating-only solo boiler — a compact wall-mounted condensing natural-gas unit documented from the specs printed on its orphaned rinnai.ca page.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- 17–N (maximum) — page print bug undefined
- Output (max)
- —
- AFUE
- —
The Rinnai Q85SN is a heating-only model in the Q-Series: a condensing boiler with a 85,000 BTU central-heating capacity and no domestic hot water production, at 110 lb.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- 26–N (maximum) — page print bug undefined
- Output (max)
- —
- AFUE
- —
The Rinnai Q130SN is a heating-only model in the Q-Series: a condensing boiler with a 130,000 BTU central-heating capacity and no domestic hot water production, at 117 lb.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- 35–175 MBH
- Output (max)
- —
- AFUE
- —
The Rinnai Q175CN is the combination model in the Q-Series: a condensing boiler with a 175,000 BTU central-heating capacity and a 6.2 GPM maximum domestic hot water flow, at 196 lb.
Natural gasCombi
DiscontinuedHistorically in Canada
- Input
- 35–N (maximum) — page print bug undefined
- Output (max)
- —
- AFUE
- —
The Rinnai Q175SN is a heating-only model in the Q-Series: a condensing boiler with a 175,000 BTU central-heating capacity and no domestic hot water production, at 141 lb.
Natural gasHeating-only
DiscontinuedHistorically in Canada
- Input
- 41–N (maximum) — page print bug undefined
- Output (max)
- —
- AFUE
- —
The Rinnai Q205SN is a heating-only model in the Q-Series: a condensing boiler with a 205,000 BTU central-heating capacity and no domestic hot water production, at 141 lb.
Natural gasHeating-only
- Input
- 15–130 MBH
- Output (max)
- —
- AFUE
- —
The Rinnai RX130iN is a SENSEI RX condensing tankless water heater — a DHW-only appliance, not a boiler — firing 15,000 to 130,000 BTU/h at 0.97 UEF with up to 7.1 GPM maximum flow.
Natural gasPropaneDHW-only (tankless)
- Input
- 15–160 MBH
- Output (max)
- —
- AFUE
- —
The Rinnai RX160iN is a SENSEI RX condensing tankless water heater — a DHW-only appliance, not a boiler — firing 15,000 to 160,000 BTU/h at 0.97 UEF with up to 9 GPM maximum flow.
Natural gasPropaneDHW-only (tankless)
- Input
- 15–180 MBH
- Output (max)
- —
- AFUE
- —
The Rinnai RX180iN is a SENSEI RX condensing tankless water heater — a DHW-only appliance, not a boiler — firing 15,000 to 180,000 BTU/h at 0.98 UEF with up to 10 GPM maximum flow.
Natural gasPropaneDHW-only (tankless)
- Input
- 15–199 MBH
- Output (max)
- —
- AFUE
- —
The Rinnai RX199iN is a SENSEI RX condensing tankless water heater — a DHW-only appliance, not a boiler — firing 15,000 to 199,000 BTU/h at 0.98 UEF with up to 11.1 GPM maximum flow.
Natural gasPropaneDHW-only (tankless)
- Input
- 15–160 MBH
- Output (max)
- —
- AFUE
- —
The Rinnai RXP160iN is a SENSEI RXP condensing tankless water heater — a DHW-only appliance, not a boiler — firing 15,000 to 160,000 BTU/h at 0.97 UEF with up to 9 GPM maximum flow.
Natural gasPropaneDHW-only (tankless)
- Input
- 15–199 MBH
- Output (max)
- —
- AFUE
- —
The Rinnai RXP199iN is a SENSEI RXP condensing tankless water heater — a DHW-only appliance, not a boiler — firing 15,000 to 199,000 BTU/h at 0.98 UEF with up to 11.1 GPM maximum flow.
Natural gasPropaneDHW-only (tankless)