- Input
- 8.3–55 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight WHB055 is the entry size of Lochinvar's wall-hung fire-tube Knight: 8.3 to 55 MBH input at 95% AFUE, with 1" water connections and 2" venting to 80 equivalent feet.
Natural gasPropaneHeating-only
- Input
- 8.5–85 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight WHB085 steps the wall-hung Knight to 8.5 to 85 MBH input at 95% AFUE, with 79 MBH DOE capacity and a 2.2-gallon water content in the same 1"-connection cabinet family.
Natural gasPropaneHeating-only
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight WHB110 is the mid-size wall-hung Knight: 11 to 110 MBH input at 95% AFUE with 102 MBH DOE heating capacity, and 2" venting limited to 40 equivalent feet.
Natural gasPropaneHeating-only
- Input
- 15.5–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight WHB155 reaches 15.5 to 155 MBH input at 95% AFUE with 144 MBH DOE capacity, and from this size upward the Knight vents in 3" pipe only.
Natural gasPropaneHeating-only
- Input
- 19.9–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight WHB199 is the 199 MBH wall-hung Knight: 19.9 to 199 MBH input at 95% AFUE, stepping up to 1 1/4" water connections and 3" venting to 100 equivalent feet.
Natural gasPropaneHeating-only
- Input
- 28.5–285 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight WHB285 is the 285 MBH wall-hung Knight: 28.5 to 285 MBH input at 95% AFUE with 264 MBH DOE capacity, 4" venting available to 100 equivalent feet and 1-1/4" connections.
Natural gasPropaneHeating-only
- Input
- 39.9–399 MBH
- Output (max)
- —
- AFUE
- —
The Knight WHB399 tops the wall-hung Knight line at 399 MBH of input and 377 MBH DOE capacity, rated by 94.4% thermal efficiency rather than AFUE, with 1-1/2" connections and 4" venting.
Natural gasPropaneHeating-only
- Input
- 8.3–55 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight KHB055 is the floor-standing counterpart of the WHB055: 8.3 to 55 MBH input at 95% AFUE with the same fire-tube ratings, in a 157 lb floor cabinet.
Natural gasPropaneHeating-only
- Input
- 8.5–85 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight KHB085 is the 85 MBH floor-standing Knight: 8.5 to 85 MBH input at 95% AFUE with 79 MBH DOE capacity, sharing the WHB085's ratings on a floor frame.
Natural gasPropaneHeating-only
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight KHB110 is the 110 MBH floor-standing Knight: 11 to 110 MBH input at 95% AFUE with 102 MBH DOE capacity, matching the wall-hung WHB110 on a floor frame.
Natural gasPropaneHeating-only
- Input
- 15.5–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight KHB155 is the 155 MBH floor-standing Knight: 15.5 to 155 MBH input at 95% AFUE with 144 MBH DOE capacity, vented in 3" pipe to 100 equivalent feet.
Natural gasPropaneHeating-only
- Input
- 19.9–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight KHB199 is the 199 MBH floor-standing Knight: 19.9 to 199 MBH input at 95% AFUE with 183 MBH DOE capacity, 1-1/4" connections and 3" venting.
Natural gasPropaneHeating-only
- Input
- 28.5–285 MBH
- Output (max)
- —
- AFUE
- 95 %
The Knight KHB285 tops the floor-standing Knight line at 28.5 to 285 MBH input and 264 MBH DOE capacity, 95% AFUE, with 3" venting to 50 feet or 4" to 100.
Natural gasPropaneHeating-only
- Input
- 8.3–80 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NKB080 is the smallest Noble heating boiler: 8.3 to 80 MBH input at 95.0% AFUE with a 1.2-gallon water content, 1" sweat connections and 2" or 3" venting to 100 feet.
Natural gasPropaneHeating-only
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NKB110 is the 110 MBH Noble heating boiler: 11 to 110 MBH input at 95.0% AFUE with 102 MBH DOE capacity, sharing the Noble ratings table with the NKC110 and NCF110 combis.
Natural gasPropaneHeating-only
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NKB150 is the 150 MBH Noble heating boiler: 15 to 150 MBH input at 95.0% AFUE with 139 MBH DOE capacity, 1" sweat connections and 2" venting to 60 equivalent feet.
Natural gasPropaneHeating-only
- Input
- 19.9–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NKB199 tops the Noble boiler line at 19.9 to 199 MBH input and 185 MBH DOE capacity, 95.0% AFUE, with 2" venting limited to 50 equivalent feet.
Natural gasPropaneHeating-only
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NKC110 is the entry Noble wall-hung combi: 11 to 110 MBH input at 95.0% AFUE, rated for DHW of up to 2.6 GPM at a 77°F rise, with 3/4" DHW connections.
Natural gasPropaneCombi
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NKC150 is the 150 MBH Noble wall-hung combi: 15 to 150 MBH space-heating input at 95.0% AFUE with 139 MBH DOE capacity and a 2-gallon water content.
Natural gasPropaneCombi
- Input
- 19.9–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NKC199 is the top Noble wall-hung combi: 19.9 to 199 MBH space-heating input at 95.0% AFUE with 185 MBH DOE capacity, DHW on demand through 3/4" connections.
Natural gasPropaneCombi
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NCF110 is the entry Noble floor-standing combi: 11 to 110 MBH input at 95.0% AFUE, rated for DHW of up to 2.6 GPM at a 77°F rise, on a 290 lb floor cabinet.
Natural gasPropaneCombi
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NCF150 is the 150 MBH floor-standing Noble combi: 15 to 150 MBH input at 95.0% AFUE with 139 MBH DOE capacity and on-demand DHW through 3/4" connections.
Natural gasPropaneCombi
- Input
- 19.9–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Noble NCF199 is the largest Noble floor combi: 19.9 to 199 MBH input at 95.0% AFUE with 185 MBH DOE capacity, on-demand DHW and 2" venting to 50 equivalent feet.
Natural gasPropaneCombi
- Input
- 39.9–399 MBH
- Output (max)
- —
- AFUE
- —
The Knight XL KBX0400 is the entry commercial Knight XL: 39.9 to 399 MBH input at 97% thermal efficiency, printing 387 MBH gross and a 337 MBH AHRI net rating, with 2" water connections and 4" air and vent sizes.
Natural gasPropaneHeating-only
- Input
- 50–500 MBH
- Output (max)
- —
- AFUE
- —
The Knight XL KBX0500 steps the commercial Knight XL to 50 to 500 MBH input with 485 MBH gross output and a 422 MBH AHRI net rating at 97% thermal efficiency, on 2" water connections.
Natural gasPropaneHeating-only
- Input
- 65–650 MBH
- Output (max)
- —
- AFUE
- —
The Knight XL KBX0650 reaches 65 to 650 MBH input with 631 MBH gross output and a 549 MBH AHRI net rating at 97% thermal efficiency, stepping the gas connection to 1-1/4" and the vent to 6".
Natural gasPropaneHeating-only
- Input
- 80–800 MBH
- Output (max)
- —
- AFUE
- —
The Knight XL KBX0800 fires 80 to 800 MBH with 776 MBH gross output and a 675 MBH AHRI net rating at 97% thermal efficiency, keeping 2" water connections with a 6" vent.
Natural gasPropaneHeating-only
- Input
- 99.9–999 MBH
- Output (max)
- —
- AFUE
- —
The Knight XL KBX1000 tops the commercial Knight XL line at 99.9 to 999 MBH input with 969 MBH gross output and an 843 MBH AHRI net rating at 97% thermal efficiency, stepping to 2-1/2" water and 6" air connections.
Natural gasPropaneHeating-only
- Input
- 39.9–399 MBH
- Output (max)
- —
- AFUE
- —
The FTXL FTX400 is the entry commercial FTXL: 39.9 to 399 MBH input with 391 MBH gross output and a 340 MBH AHRI net rating at 98.0% submittal thermal efficiency, with 10:1 turndown.
Natural gasPropaneHeating-only
- Input
- 50–500 MBH
- Output (max)
- —
- AFUE
- —
The FTXL FTX500 fires 50 to 500 MBH with 489 MBH gross output and a 425 MBH AHRI net rating at 97.7% submittal thermal efficiency, keeping 2" water connections and 4" venting.
Natural gasPropaneHeating-only
- Input
- 85.7–600 MBH
- Output (max)
- —
- AFUE
- —
The FTXL FTX600 reaches 85.7 to 600 MBH input with 585 MBH gross output and a 509 MBH AHRI net rating at 97.5% submittal thermal efficiency, with 7:1 turndown.
Natural gasPropaneHeating-only
- Input
- 103.6–725 MBH
- Output (max)
- —
- AFUE
- —
The FTXL FTX725 fires 103.6 to 725 MBH with 705 MBH gross output and a 613 MBH AHRI net rating at 97.2% submittal thermal efficiency, stepping to 2-1/2" water connections and a 6" vent.
Natural gasPropaneHeating-only
- Input
- 121.4–850 MBH
- Output (max)
- —
- AFUE
- —
The FTXL FTX850 fires 121.4 to 850 MBH with 825 MBH gross output and a 717 MBH AHRI net rating at 97.0% submittal thermal efficiency, on 2-1/2" water connections with 6" venting.
Natural gasPropaneHeating-only
- Input
- 100–1000 MBH
- Output (max)
- —
- AFUE
- —
The FTXL FTX1000 tops the FTXL line at 100 to 1000 MBH input with 982 MBH gross output and an 854 MBH AHRI net rating at 98.3% submittal thermal efficiency — the "FTXL 1.0" 999,000 model.
Natural gasPropaneHeating-only
- Input
- 50–750 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN0751 opens the Crest FB line at 50 to 750 MBH input with 722 MBH gross output and a 626 MBH AHRI net rating, on 3" pipe connections with 6" air and vent — 15:1 turndown.
Natural gasPropaneHeating-only
- Input
- 50–999 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN1001 fires 50 to 999 MBH with 961 MBH gross output and an 834 MBH AHRI net rating — the 96.2% thermal efficiency model whose page opens the Crest FB line, at 20:1 turndown.
Natural gasPropaneHeating-only
- Input
- 62.5–1250 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN1251 fires 62.5 to 1250 MBH with 1203 MBH gross output and a 1043 MBH AHRI net rating at 20:1 turndown, stepping the gas inlet to 1-1/2" and the vent to 8".
Natural gasPropaneHeating-only
- Input
- 60–1500 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN1501 fires 60 to 1500 MBH with 1443 MBH gross output and a 1252 MBH AHRI net rating at 25:1 turndown, stepping the Crest to 4" pipe and 8" air and vent.
Natural gasPropaneHeating-only
- Input
- 70–1750 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN1751 fires 70 to 1750 MBH with 1684 MBH gross output and a 1461 MBH AHRI net rating at 25:1 turndown, keeping 4" pipe and 8" air and vent sizes.
Natural gasPropaneHeating-only
- Input
- 80–1999 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN2001 fires 80 to 1999 MBH with 1923 MBH gross output and a 1699 MBH AHRI net rating at 25:1 turndown, closing the 25:1 band of the FB line.
Natural gasPropaneHeating-only
- Input
- 125–2500 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN2501 fires 125 to 2500 MBH with 2400 MBH gross output and a 2087 MBH AHRI net rating at 20:1 turndown, stepping the gas inlet to 2" with a 9" vent.
Natural gasPropaneHeating-only
- Input
- 150–3000 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN3001 fires 150 to 3000 MBH with 2883 MBH gross output and a 2507 MBH AHRI net rating at 20:1 turndown, stepping air and vent to 10" at a 3.0 million BTU/hr ceiling.
Natural gasPropaneHeating-only
- Input
- 175–3500 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN3501 fires 175 to 3500 MBH with 3364 MBH gross output and a 2925 MBH AHRI net rating at 20:1 turndown, with a 202-gallon water content on 4" pipe.
Natural gasPropaneHeating-only
- Input
- 333.3–3999 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN4001 fires 333.3 to 3999 MBH with 3843 MBH gross output and a 3342 MBH AHRI net rating at 12:1 turndown, stepping air and vent to 12" with a 2-1/2" gas inlet.
Natural gasPropaneHeating-only
- Input
- 499.9–4999 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN5001 fires 499.9 to 4999 MBH with 4804 MBH gross output and a 4177 MBH AHRI net rating at 10:1 turndown, stepping the Crest to 6" pipe and 14" air and vent.
Natural gasPropaneHeating-only
- Input
- 600–6000 MBH
- Output (max)
- —
- AFUE
- —
The Crest FBN6001 tops the Crest FB line at 600 to 6000 MBH input with 5766 MBH gross output and a 5014 MBH AHRI net rating at 10:1 turndown, on 6" pipe with a 3" gas inlet.
Natural gasPropaneHeating-only
- Input
- 50–999 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB1000 opens the FCB line at 50 to 999 MBH input with 961 MBH gross output and an 834 MBH AHRI net rating, on 3" pipe with 6" air and vent.
Natural gasPropaneHeating-only
- Input
- 60–1500 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB1500 fires 60 to 1500 MBH with 1443 MBH gross output and a 1252 MBH AHRI net rating, stepping the Hellcat line to 4" pipe and 8" air and vent.
Natural gasPropaneHeating-only
- Input
- 80–1999 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB2000 fires 80 to 1999 MBH with 1923 MBH gross output and a 1699 MBH AHRI net rating, keeping 4" pipe and 8" air and vent at the top of the small FCB sizes.
Natural gasPropaneHeating-only
- Input
- 125–2500 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB2500 fires 125 to 2500 MBH with 2400 MBH gross output and a 2087 MBH AHRI net rating — the entry of the FCB sizes Lochinvar's page copy rates at 20:1 turndown.
Natural gasPropaneHeating-only
- Input
- 150–3000 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB3000 fires 150 to 3000 MBH with 2883 MBH gross output and a 2507 MBH AHRI net rating, stepping air and vent to 10" on the Hellcat platform.
Natural gasPropaneHeating-only
- Input
- 200–3999 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB4000 fires 200 to 3999 MBH with 3843 MBH gross output and a 3342 MBH AHRI net rating at 96% thermal efficiency per its product page, with 12" air and vent.
Natural gasPropaneHeating-only
- Input
- 250–4999 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB5000 fires 250 to 4999 MBH with 4804 MBH gross output and a 4177 MBH AHRI net rating, stepping the Hellcat line to 6" pipe and 14" air and vent.
Natural gasPropaneHeating-only
- Input
- 300–6000 MBH
- Output (max)
- —
- AFUE
- —
The Crest with Hellcat FCB6000 tops the FCB range at 300 to 6000 MBH input with 5766 MBH gross output and a 5014 MBH AHRI net rating, on 6" pipe with a 3" gas inlet.
Natural gasPropaneHeating-only
- Input
- 157.5–315 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN315 is the entry size of the line: 157.5 to 315 MBH input with 258 MBH gross output and a 224 MBH AHRI net rating at 82.0% thermal efficiency, on 2" water and 3/4" gas connections with an 8" Category I vent.
Natural gasPropaneHeating-only
- Input
- 180–360 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN360 covers 180 to 360 MBH input with 295 MBH gross output and a 257 MBH AHRI net rating at 82.0% thermal efficiency — the size whose page anchors Lochinvar's current atmospheric Copper-Fin listing.
Natural gasPropaneHeating-only
- Input
- 199.5–399 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN399 runs 199.5 to 399 MBH input with 328 MBH gross output and a 285 MBH AHRI net rating at 82.0% thermal efficiency, stepping up to a 10" vent and a 1" gas connection.
Natural gasPropaneHeating-only
- Input
- 250–500 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN500 tops the atmospheric line at 250 to 500 MBH input with 410 MBH gross output and a 357 MBH AHRI net rating at 82.0% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 250–495 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0497 opens the eight-size line at 250 to 495 MBH input with 416 MBH gross output and a 362 MBH AHRI net rating at 84% thermal efficiency, on a 6" vent.
Natural gasPropaneHeating-only
- Input
- 350–645 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0647 steps to 350 to 645 MBH input with 542 MBH gross output and a 471 MBH AHRI net rating at 84% thermal efficiency and an 8" vent.
Natural gasPropaneHeating-only
- Input
- 350–745 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0747 reaches 350 to 745 MBH input with 626 MBH gross output and a 544 MBH AHRI net rating at 84% thermal efficiency, closing the 2" water-connection group.
Natural gasPropaneHeating-only
- Input
- 360–985 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0987 moves into the larger cabinet: 360 to 985 MBH input with 827 MBH gross output and a 719 MBH AHRI net rating at 84% thermal efficiency, on 2-1/2" water and 2" gas connections.
Natural gasPropaneHeating-only
- Input
- 720–1255 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN1257 covers 720 to 1,255 MBH input with 1,054 MBH gross output and a 917 MBH AHRI net rating at 84% thermal efficiency, moving to a 12" vent.
Natural gasPropaneHeating-only
- Input
- 720–1435 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN1437 reaches 720 to 1,435 MBH input with 1,205 MBH gross output and a 1,048 MBH AHRI net rating at 84% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 720–1795 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN1797 covers 720 to 1,795 MBH input with 1,508 MBH gross output and a 1,311 MBH AHRI net rating at 84% thermal efficiency, stepping up to a 14" vent.
Natural gasPropaneHeating-only
- Input
- 990–2065 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN2067 tops the line at 990 to 2,065 MBH input with 1,735 MBH gross output and a 1,508 MBH AHRI net rating at 84% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 250–399 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0402 opens the line at 250 to 399 MBH input with 339 MBH gross output and a 295 MBH AHRI net rating at 85% thermal efficiency, with the SMART SYSTEM control and up to 4:1 proportional firing.
Natural gasPropaneHeating-only
- Input
- 250–500 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0502 covers 250 to 500 MBH input with 425 MBH gross output and a 370 MBH AHRI net rating at 85% thermal efficiency on a 6" vent.
Natural gasPropaneHeating-only
- Input
- 250–650 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0652 covers 250 to 650 MBH input with 553 MBH gross output and a 481 MBH AHRI net rating at 85% thermal efficiency, moving to an 8" vent and air inlet.
Natural gasPropaneHeating-only
- Input
- 250–750 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0752 reaches 250 to 750 MBH input with 638 MBH gross output and a 555 MBH AHRI net rating at 85% thermal efficiency, closing the 2" water-connection group.
Natural gasPropaneHeating-only
- Input
- 360–990 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0992 moves to the larger cabinet and 2-1/2" water connections: 360 to 990 MBH input with 842 MBH gross output and a 732 MBH AHRI net rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 360–1260 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN1262 covers 360 to 1,260 MBH input with 1,071 MBH gross output and a 931 MBH AHRI net rating at 85% thermal efficiency on a 12" vent.
Natural gasPropaneHeating-only
- Input
- 360–1440 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN1442 reaches 360 to 1,440 MBH input with 1,224 MBH gross output and a 1,064 MBH AHRI net rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 360–1800 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN1802 covers 360 to 1,800 MBH input with 1,530 MBH gross output and a 1,330 MBH AHRI net rating at 85% thermal efficiency, with a 14" vent and 12" air inlet.
Natural gasPropaneHeating-only
- Input
- 630–2070 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN2072 tops the line at 630 to 2,070 MBH input with 1,760 MBH gross output and a 1,530 MBH AHRI net rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 100–500 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN0502-M9 is a non-condensing copper-tube vertical commercial boiler rated 100-500 MBH input, 425 MBH gross output and a 370 MBH net AHRI water rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 150–750 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN0752-M9 is a non-condensing copper-tube vertical commercial boiler rated 150-750 MBH input, 638 MBH gross output and a 554 MBH net AHRI water rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 199.8–999 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN1002-M9 is a non-condensing copper-tube vertical commercial boiler rated 199.8-999 MBH input, 849 MBH gross output and a 739 MBH net AHRI water rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 260–1300 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN1302-M9 is a non-condensing copper-tube vertical commercial boiler rated 260-1,300 MBH input, 1,105 MBH gross output and a 961 MBH net AHRI water rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 300–1500 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN1501-M9 is a non-condensing copper-tube vertical commercial boiler rated 300-1,500 MBH input, 1,275 MBH gross output and a 1,109 MBH net AHRI water rating at 84% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 340–1700 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN1701-M9 is a non-condensing copper-tube vertical commercial boiler rated 340-1,700 MBH input, 1,445 MBH gross output and a 1,257 MBH net AHRI water rating at 84% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 440–2000 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN2001-M9 is a non-condensing copper-tube vertical commercial boiler rated 440-2,000 MBH input, 1,700 MBH gross output and a 1,478 MBH net AHRI water rating at 84% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN2500 is a non-condensing copper-tube vertical commercial boiler rated 2,500 BTU/hr input, 2,175 MBH gross output and a 1,891 MBH net AHRI water rating at 87% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN3000 is a non-condensing copper-tube vertical commercial boiler rated 3,000 BTU/hr input, 2,610 MBH gross output and a 2,270 MBH net AHRI water rating at 87% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN3500 is a non-condensing copper-tube vertical commercial boiler rated 3,500 BTU/hr input, 3,045 MBH gross output and a 2,648 MBH net AHRI water rating at 87% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN4000 is a non-condensing copper-tube vertical commercial boiler rated 4,000 BTU/hr input, 3,480 MBH gross output and a 3,026 MBH net AHRI water rating at 87% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Power-fin PBN5000 is a non-condensing copper-tube vertical commercial boiler rated 4,999 BTU/hr input, 4,349 MBH gross output and a 3,782 MBH net AHRI water rating at 87% thermal efficiency.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 100–1000 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar SYNC SBN1000 is a discontinued commercial condensing boiler rated 100-1,000 MBH input with 941 MBH gross output and an 818 MBH net AHRI water rating, documented on Lochinvar's "Series Discontinued" support page.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 130–1300 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar SYNC SBN1300 is a discontinued commercial condensing boiler rated 130-1,300 MBH input with 1,237 MBH gross output and an 1,076 MBH net AHRI water rating, documented on Lochinvar's "Series Discontinued" support page.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 150–1500 MBH
- Output (max)
- —
- AFUE
- —
The Lochinvar SYNC SBN1500 is a discontinued commercial condensing boiler rated 150-1,500 MBH input with 1,444 MBH gross output and an 1,256 MBH net AHRI water rating, documented on Lochinvar's "Series Discontinued" support page.
Natural gasPropaneHeating-only
- Input
- 8.3–80 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPB080N is a wall-mounted heating-only boiler rated 8.3-80 MBH input, 74 MBH DOE heating capacity and a 64 MBH net AHRI rating at 95% AFUE.
Natural gasPropaneHeating-only
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPB110N is a wall-mounted heating-only boiler rated 11-110 MBH input, 102 MBH DOE heating capacity and a 89 MBH net AHRI rating at 95% AFUE.
Natural gasPropaneHeating-only
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPB150N is a wall-mounted heating-only boiler rated 15-150 MBH input, 139 MBH DOE heating capacity and a 125 MBH net AHRI rating at 95% AFUE.
Natural gasPropaneHeating-only
- Input
- 19.9–199.9 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPB199N is a wall-mounted heating-only boiler rated 19.9-199.9 MBH input, 185 MBH DOE heating capacity and a 161 MBH net AHRI rating at 95% AFUE.
Natural gasPropaneHeating-only
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPC110N is a wall-mounted combination boiler rated 11-110 MBH input, 102 MBH DOE heating capacity and a 89 MBH net AHRI rating at 95% AFUE and delivers 2.6 gpm of domestic hot water at a 77°F temperature rise.
Natural gasPropaneCombi
- Input
- 11–99.9 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPC110N-CAN is a wall-mounted combination boiler rated 11-99.9 MBH input, 92 MBH DOE heating capacity and a 80 MBH net AHRI rating at 95% AFUE and delivers 2.6 gpm of domestic hot water at a 77°F temperature rise.
Natural gasPropaneCombi
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPC150N is a wall-mounted combination boiler rated 15-150 MBH input, 139 MBH DOE heating capacity and a 121 MBH net AHRI rating at 95% AFUE and delivers 3.6 gpm of domestic hot water at a 77°F temperature rise.
Natural gasPropaneCombi
- Input
- 20–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EPC199N is a wall-mounted combination boiler rated 20-199 MBH input, 185 MBH DOE heating capacity and a 161 MBH net AHRI rating at 95% AFUE and delivers 4.8 gpm of domestic hot water at a 77°F temperature rise.
Natural gasPropaneCombi
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EFC110N is a floor-standing combination boiler rated 11-110 MBH input, 102 MBH DOE heating capacity and a 89 MBH net AHRI rating at 95% AFUE and delivers 2.6 gpm of domestic hot water at a 77°F temperature rise.
Natural gasPropaneCombi
- Input
- 15–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EFC150N is a floor-standing combination boiler rated 15-150 MBH input, 139 MBH DOE heating capacity and a 121 MBH net AHRI rating at 95% AFUE and delivers 3.6 gpm of domestic hot water at a 77°F temperature rise.
Natural gasPropaneCombi
- Input
- 19.9–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Epic EFC199N is a floor-standing combination boiler rated 19.9-199 MBH input, 185 MBH DOE heating capacity and a 161 MBH net AHRI rating at 95% AFUE and delivers 4.8 gpm of domestic hot water at a 77°F temperature rise.
Natural gasPropaneCombi
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT030 is a 27-gallon single-wall indirect water heater with a 316L stainless steel tank and coil, 1.5°F/hr standby loss and a 79 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT040 is a 40-gallon single-wall indirect water heater with a 316L stainless steel tank and coil, 0.9°F/hr standby loss and a 105 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT050 is a 52-gallon single-wall indirect water heater with a 316L stainless steel tank and coil, 0.9°F/hr standby loss and a 131 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT065 is a 67-gallon single-wall indirect water heater with a 316L stainless steel tank and coil, 0.7°F/hr standby loss and a 147 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT080 is a 82-gallon single-wall indirect water heater with a 316L stainless steel tank and coil, 0.6°F/hr standby loss and a 177 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT119 is a 113-gallon single-wall indirect water heater with a 316L stainless steel tank and coil, 0.5°F/hr standby loss and a 213 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT040DW is a 38-gallon double-wall indirect water heater with a 316L stainless steel tank and coil, 1.5°F/hr standby loss and a 130 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT050DW is a 50-gallon double-wall indirect water heater with a 316L stainless steel tank and coil, 0.9°F/hr standby loss and a 150 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT065DW is a 63-gallon double-wall indirect water heater with a 316L stainless steel tank and coil, 0.7°F/hr standby loss and a 229 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT080DW is a 80-gallon double-wall indirect water heater with a 316L stainless steel tank and coil, 0.6°F/hr standby loss and a 245 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SIT119DW is a 113-gallon double-wall indirect water heater with a 316L stainless steel tank and coil, 0.5°F/hr standby loss and a 315 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SDT065 is a 66-gallon solar indirect water heater with a 316L stainless steel tank and coil, 0.5°F/hr standby loss and a 158 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SDT080 is a 79-gallon solar indirect water heater with a 316L stainless steel tank and coil, 0.5°F/hr standby loss and a 188 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SDT119 is a 110-gallon solar indirect water heater with a 316L stainless steel tank and coil, 0.4°F/hr standby loss and a 224 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SET065 is a 67-gallon solar with electric backup indirect water heater with a 316L stainless steel tank and coil, 0.5°F/hr standby loss and a 149 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SET080 is a 81-gallon solar with electric backup indirect water heater with a 316L stainless steel tank and coil, 0.5°F/hr standby loss and a 179 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Squire SET119 is a 113-gallon solar with electric backup indirect water heater with a 316L stainless steel tank and coil, 0.5°F/hr standby loss and a 215 lb shipping weight.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH0400NPM is a floor-standing commercial condensing water heater rated 399,000 BTU/hr input at 99% thermal efficiency with 479 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH0500NPM is a floor-standing commercial condensing water heater rated 500,000 BTU/hr input at 99% thermal efficiency with 600 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH0650NPM is a floor-standing commercial condensing water heater rated 650,000 BTU/hr input at 98% thermal efficiency with 772 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH0800NPM is a floor-standing commercial condensing water heater rated 800,000 BTU/hr input at 98% thermal efficiency with 950 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH1000NPM is a floor-standing commercial condensing water heater rated 999,000 BTU/hr input at 98% thermal efficiency with 1,187 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH1250NPM is a floor-standing commercial condensing water heater rated 1,250,000 BTU/hr input at 98% thermal efficiency with 1,485 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH1500NPM is a floor-standing commercial condensing water heater rated 1,500,000 BTU/hr input at 98% thermal efficiency with 1,782 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH2000NPM is a floor-standing commercial condensing water heater rated 1,999,000 BTU/hr input at 98% thermal efficiency with 2,375 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH3000NPM is a floor-standing commercial condensing water heater rated 3,000,000 BTU/hr input at 98% thermal efficiency with 3,564 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWH4000NPM is a floor-standing commercial condensing water heater rated 4,000,000 BTU/hr input at 98% thermal efficiency with 4,752 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN151PM is a light-commercial floor-mounted condensing water heater rated 150,000 BTU/hr input at 96% thermal efficiency with 175 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN200PM is a light-commercial floor-mounted condensing water heater rated 199,000 BTU/hr input at 96% thermal efficiency with 232 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN286PM is a light-commercial floor-mounted condensing water heater rated 285,000 BTU/hr input at 96% thermal efficiency with 332 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN400PM is a light-commercial floor-mounted condensing water heater rated 399,000 BTU/hr input at 96% thermal efficiency with 464 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN501PM is a light-commercial floor-mounted condensing water heater rated 500,000 BTU/hr input at 96% thermal efficiency with 582 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN601PM is a light-commercial floor-mounted condensing water heater rated 600,000 BTU/hr input at 96% thermal efficiency with 699 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN701PM is a light-commercial floor-mounted condensing water heater rated 700,000 BTU/hr input at 96% thermal efficiency with 815 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor AWN801PM is a light-commercial floor-mounted condensing water heater rated 800,000 BTU/hr input at 96% thermal efficiency with 931 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN151PM is a outdoor condensing commercial water heater rated 150,000 BTU/hr input at 96% thermal efficiency with 175 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN200PM is a outdoor condensing commercial water heater rated 199,000 BTU/hr input at 96% thermal efficiency with 232 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN286PM is a outdoor condensing commercial water heater rated 285,000 BTU/hr input at 96% thermal efficiency with 332 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN400PM is a outdoor condensing commercial water heater rated 399,000 BTU/hr input at 96% thermal efficiency with 464 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN501PM is a outdoor condensing commercial water heater rated 500,000 BTU/hr input at 96% thermal efficiency with 582 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN601PM is a outdoor condensing commercial water heater rated 600,000 BTU/hr input at 96% thermal efficiency with 698 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN701PM is a outdoor condensing commercial water heater rated 700,000 BTU/hr input at 96% thermal efficiency with 815 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor OAN801PM is a outdoor condensing commercial water heater rated 800,000 BTU/hr input at 96% thermal efficiency with 931 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor WAN125PM is a wall-mounted commercial condensing water heater rated 125,000 BTU/hr input at 96% thermal efficiency with 145 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor WAN200PM is a wall-mounted commercial condensing water heater rated 199,000 BTU/hr input at 96% thermal efficiency with 232 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
- Input
- —
- Output (max)
- —
- AFUE
- —
The Lochinvar Armor WAN201PM is a wall-mounted commercial condensing water heater rated 201,000 BTU/hr input at 96% thermal efficiency with 232 GPH recovery at a 100°F rise.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- 11–55 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight WHN055 is a discontinued wall-hung fire-tube boiler rated 11-55 MBH input with 51 MBH gross output and a 44 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 17–85 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight WHN085 is a discontinued wall-hung fire-tube boiler rated 17-85 MBH input with 79 MBH gross output and a 69 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 22–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight WHN110 is a discontinued wall-hung fire-tube boiler rated 22-110 MBH input with 102 MBH gross output and a 89 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 31–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight WHN155 is a discontinued wall-hung fire-tube boiler rated 31-155 MBH input with 144 MBH gross output and a 125 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 40–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight WHN199 is a discontinued wall-hung fire-tube boiler rated 40-199 MBH input with 184 MBH gross output and a 160 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 57–285 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight WHN285 is a discontinued wall-hung fire-tube boiler rated 57-285 MBH input with 264 MBH gross output and a 229 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 80–399 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight WHN399 is a discontinued wall-hung fire-tube boiler rated 80-399 MBH input with 379 MBH gross output and a 330 MBH net AHRI water rating at 95% thermal efficiency.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 8.2–55 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight KHN055 is a discontinued floor-standing fire-tube boiler rated 8.2-55 MBH input with 51 MBH gross output and a 44 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 8.5–85 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight KHN085 is a discontinued floor-standing fire-tube boiler rated 8.5-85 MBH input with 79 MBH gross output and a 69 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight KHN110 is a discontinued floor-standing fire-tube boiler rated 11-110 MBH input with 102 MBH gross output and a 89 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 15.5–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight KHN155 is a discontinued floor-standing fire-tube boiler rated 15.5-155 MBH input with 144 MBH gross output and a 125 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 20–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight KHN199 is a discontinued floor-standing fire-tube boiler rated 20-199 MBH input with 184 MBH gross output and a 160 MBH net AHRI water rating at 95% AFUE.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 28.5–285 MBH
- Output (max)
- —
- AFUE
- 95 %
The Lochinvar Knight KHN285 is a discontinued floor-standing fire-tube boiler rated 28.5-285 MBH input with 264 MBH gross output and a 229 MBH net AHRI water rating at 95% AFUE.