Skip to content
Boilers.caby ROMA Heating & Cooling

Brand hub

Peerless Boilers boilers in Canada

Peerless Boilers (PB Heat) is an American boiler manufacturer. Boilers.ca documents its current gas line-up — the PureFire stainless condensing boiler, the Series PBC combi, the Series MI-e cast-iron boiler and the current commercial Series CC, GM and TCII — plus the Series 63 steam, PSCII and legacy Series DE, MI, MIHII, Cast 92 and LC/LCE hubs. The Pinnacle and Series WB90 names belong to oil-fired boilers the official site groups under 'Out of Circulation', so no series pages are published for them.

Canadian status unknown

At a glance

Official site
Global site
Country
United States
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Documented series
13
Documented models
60

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

About Peerless Boilers

Peerless Boilers is an American boiler manufacturer publishing from peerlessboilers.com and identifying itself on the site as 'PB Heat: Peerless Boilers'. Its product catalogue covers cast-iron gas and oil boilers and stainless condensing equipment for residential and light-commercial duty. No official statement of Canadian sales was found on the official pages, so Boilers.ca records the brand's canadianStatus as 'unknown'.

Boilers.ca documents Peerless' gas line-up from the official pages and manuals (verified September 9, 2026): the PureFire stainless-steel condensing line (PF-50 through PF-399, with model-level pages for every PF size), the Series PBC condensing combination boiler (PBC-34/PBC-40/PBC-52, model-level), the Series MI-e cast-iron water boiler (MI-e-03 through MI-e-09, model-level), the Series 63 and 63-x steam hub, the sealed-combustion Series PSCII hub, and the legacy hubs Series DE, Series MI (MI-03 through MI-09, model-level), Series MIHII (MIHII-03 through MIHII-06, model-level), Cast 92 (92-2 and 92-4, model-level) and Series LC/LCE. The current commercial hubs Series CC (CC-03–CC-12), Series GM (GM-e-05/GM-e-06/GM-07/GM-08) and Series TCII (TCII-04–TCII-18) are documented at series level with their printed sizes and ratings. All research reviewed US-site data only; canadianStatus stays 'unknown' for the series and models.

Two naming checks matter for this site. The Peerless 'Pinnacle' product page describes the Pinnacle as Peerless' oil-fired condensing residential boiler (PO-70/PO-70A/PO-84/PO-84A models, 70 to 84 MBH input) and groups it under an 'Out of Circulation' heading. The Series WB90 page describes an oil-fired residential boiler (WB90-03/WB90-04, 70–182 MBH input) with a flame-retention burner on No. 2 fuel oil, also under 'Out of Circulation'. Because Boilers.ca documents gas-fired equipment and never repurposes a series for the wrong fuel, no Pinnacle or WB90 series page is published here. Owners of an installed Peerless boiler should have gas, combustion and venting work performed by a licensed contractor against the documentation for the unit's own line.

Series

Peerless Boilers boiler series

Each series hub lists its models, verified specifications, manuals and documented alerts.

  • PureFire

    current

    The Peerless PureFire is the brand's current stainless-steel, gas condensing boiler line, sold for residential/light-commercial use: modulating models PF-50 through PF-210 (50–210 MBH maximum input) at 95.0–95.1% AFUE, plus PF-300 and PF-399 sizes whose cut-sheet rows print 96.5%/95.2% thermal efficiency, on a direct-vent sealed-combustion system with a plain-English LCD control.

    condensingNatural gasPropane95.1% AFUE

    8 models, specs and manuals →

  • The Series PBC ('Peerless Combi') is Peerless' current gas-fired condensing combination boiler: wall-hung models PBC-34, PBC-40 and PBC-52 deliver space heating (80–120 MBH maximum CH input) plus on-demand domestic hot water at up to 5.2 GPM, rated 95.1–95.3% AFUE with up to 10:1 turndown and a stainless steel heat exchanger.

    combiNatural gasPropane95.3% AFUE

    3 models, specs and manuals →

  • The Series MI-e is Peerless' current residential cast-iron, natural-draft gas hot water boiler at 84% AFUE (DOE 2021 compliant): seven fixed-input sizes MI-e-03 through MI-e-09 from 70 to 280 MBH input on the Hydrostat IC integrated boiler control with spark ignition, integral low water cut-off and boiler reset.

    non-condensingNatural gasPropane84.6% AFUE

    7 models, specs and manuals →

  • Series 63

    current

    The Series 63 is Peerless' current residential cast-iron steam boiler line: the natural-draft Series 63 (88.5–287.5 MBH input, models 63-03L through 63-06, steam output 74–238 MBH) and the natural-gas Series 63-x (63-x-03 through 63-x-06, 100–250 MBH input, 82% AFUE) with spark ignition and complete near-boiler piping kits.

    non-condensingNatural gasPropane83% AFUE

    0 models, specs and manuals →

  • The Series PSCII is Peerless' current residential cast-iron, sealed-combustion direct-vent gas hot water boiler for homes without a usable chimney: four sizes PSC II-03 through PSC II-06 at 65–150 MBH input, 56–128 MBH output and up to 86% AFUE, backed by the Peerless non-prorated lifetime heat exchanger warranty claim.

    non-condensingNatural gasPropane86% AFUE

    0 models, specs and manuals →

  • Series DE

    discontinued

    The Series DE is Peerless' legacy residential cast-iron gas hot water boiler (70–165 MBH input, 58–136 MBH output) designed for a conventional chimney or direct through-the-wall venting — the official site groups the line under 'Out of Circulation', and Boilers.ca records it as a discontinued/legacy hub without model pages.

    non-condensingNatural gasPropane82.1% AFUE

    0 models, specs and manuals →

  • Series MI

    discontinued

    The Series MI is Peerless' legacy residential cast-iron gas hot water boiler — seven fixed-input sizes MI-03 through MI-09 from 70 to 260 MBH input and 58 to 211 MBH output at 82.0–82.2% AFUE, natural-draft chimney venting with a front-facing integral draft diverter. The official site groups the line under 'Out of Circulation'.

    non-condensingNatural gasPropane82.2% AFUE

    7 models, specs and manuals →

  • Series MIHII

    discontinued

    The Series MIHII is Peerless' legacy mid-efficiency residential cast-iron gas water boiler — four sizes MIHII-03 through MIHII-06 from 65 to 162.5 MBH input at 84.0–84.1% AFUE, with a low-water cutoff, natural-draft integral draft diverter and spark-pilot ignition. The official site groups the line under 'Out of Circulation'.

    non-condensingNatural gas84.1% AFUE

    4 models, specs and manuals →

  • Cast 92

    discontinued

    The Cast 92 is Peerless' legacy gas-fired condensing cast-iron boiler family — the residential Cast 92-2 (40–199 MBH input at 90% AFUE) and the commercial/large-residential Cast 92-4 (80–399 MBH input at 92.7% thermal efficiency), both sealed-combustion direct vent with a HeatNet text-display control. The official site groups both under 'Out of Circulation'.

    condensingNatural gasPropane90% AFUE

    2 models, specs and manuals →

  • Series LC/LCE

    discontinued

    The Series LC/LCE is Peerless' legacy commercial cast-iron forced-draft boiler line for hot water or steam — 22 sizes (LC-04 through LC-12 and LCE-13 through LCE-24) with gas inputs of 686 to 4,663 MBH, outputs of 547 to 3,777 MBH and thermal efficiencies up to 83.7% as printed. The official site groups the line under 'Out of Circulation'.

    non-condensingNatural gas83.7% thermal-efficiency

    0 models, specs and manuals →

  • Series CC

    current

    The Series CC is Peerless' current commercial cast-iron steam or hot water boiler — 10 sizes CC-03 through CC-12 with gas inputs of 375 to 2,165 MBH (oil 2.6–15.0 GPH), gross outputs of 308 to 1,750 MBH, thermal efficiencies up to 84.6% and domestic hot water outputs of 8.5 to 26.9 GPM, on a forced-draft power burner for gas, oil or combination gas/oil firing.

    non-condensingNatural gas84.6% thermal-efficiency

    10 models, specs and manuals →

  • Series GM

    current

    The Series GM is Peerless' current semi-commercial cast-iron gas boiler — four sizes (GM-e-05, GM-e-06, GM-07, GM-08) from 214.5 to 399 MBH input and 182 to 320 MBH output, natural-draft chimney venting for single, multiple or modular installations, up to a 100 PSIG relief valve, with 84.0–84.2% AFUE on the GM-e sizes and 80.3% thermal efficiency on GM-07/GM-08.

    non-condensingNatural gasPropane84.2% AFUE

    4 models, specs and manuals →

  • The Series TCII is Peerless' current commercial cast-iron steam or hot water boiler — 15 sizes TCII-04 through TCII-18 with gas inputs of 1,143 to 5,553 MBH (oil 1,106–5,390 MBH, 7.9–38.5 GPH), gross outputs of 931 to 4,622 MBH and thermal efficiencies up to 85.8%, on a forced-draft power burner with flexible graphite port connectors and individual draw rods.

    non-condensingNatural gas85.8% thermal-efficiency

    15 models, specs and manuals →

Models

Peerless Boilers models with verified specifications

Peerless Boilers

Peerless PureFire PF-50

CurrentCanadian status unknown
Input
16–50 MBH
Output (max)
—
AFUE
95 %

The Peerless PureFire PF-50 fires 16 to 50 MBH input with 47 MBH heating capacity and a 41 MBH net water rating at 95% AFUE — the smallest PureFire size and the entry point for the stainless condensing line — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-80

CurrentCanadian status unknown
Input
20–80 MBH
Output (max)
—
AFUE
95 %

The Peerless PureFire PF-80 fires 20 to 80 MBH input with 75 MBH heating capacity and a 65 MBH net water rating at 95% AFUE — a mid-small size sharing the compact cabinet of the PF-50 — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-110

CurrentCanadian status unknown
Input
27.5–110 MBH
Output (max)
—
AFUE
95 %

The Peerless PureFire PF-110 fires 27.5 to 110 MBH input with 103 MBH heating capacity and a 90 MBH net water rating at 95% AFUE — the first of the wider mid-range cabinets (21 × 23 × 36 inch carton) — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-140

CurrentCanadian status unknown
Input
35–140 MBH
Output (max)
—
AFUE
95 %

The Peerless PureFire PF-140 fires 35 to 140 MBH input with 131 MBH heating capacity and a 114 MBH net water rating at 95% AFUE — the top size in the small-cabinet group (PF-50/PF-80/PF-110/PF-140) — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-200

CurrentCanadian status unknown
Input
42–199 MBH
Output (max)
—
AFUE
95 %

The Peerless PureFire PF-200 fires 42 to 199 MBH input with 185 MBH heating capacity and a 161 MBH net water rating at 95% AFUE — the first of the two large cabinet sizes (21 × 24 × 48 inch carton) with a 199 MBH cap — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-210

CurrentCanadian status unknown
Input
42–210 MBH
Output (max)
—
AFUE
95.1 %

The Peerless PureFire PF-210 fires 42 to 210 MBH input with 195 MBH heating capacity and a 170 MBH net water rating at 95.1% AFUE — the largest residential AFUE row — 42–210 MBH at 95.1% AFUE, alongside (not merged with) the PF-200 — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-300

CurrentCanadian status unknown
Input
60–300 MBH
Output (max)
—
AFUE
—

The Peerless PureFire PF-300 fires 60 to 300 MBH input with 290 MBH gross output and a 252 MBH net rating at 96.5% thermal efficiency — the 300 MBH commercial-capable size — rated by gross output and thermal efficiency, and not ENERGY STAR certified per the product page — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-399

CurrentCanadian status unknown
Input
80–399 MBH
Output (max)
—
AFUE
—

The Peerless PureFire PF-399 fires 80 to 399 MBH input with 380 MBH gross output and a 330 MBH net rating at 95.2% thermal efficiency — the largest PF model — 80–399 MBH input with a 380 MBH gross output row at 95.2% thermal efficiency — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
15.5–80 MBH
Output (max)
—
AFUE
95.1 %

The Peerless Series PBC PBC-34 is the smallest combi in the current combi range: space heating at 15.5–80 MBH input with a DHW side firing 15.5–130 MBH, delivering 3.4 GPM at a 70°F rise at 95.1% AFUE on the wall-hung stainless platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
15.5–100 MBH
Output (max)
—
AFUE
95.2 %

The Peerless Series PBC PBC-40 is the 10:1-turndown middle size in the current combi range: space heating at 15.5–100 MBH input with a DHW side firing 15.5–155 MBH, delivering 4 GPM at a 70°F rise at 95.2% AFUE on the wall-hung stainless platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
24.5–120 MBH
Output (max)
—
AFUE
95.3 %

The Peerless Series PBC PBC-52 is the largest combi at up to 5.2 GPM in the current combi range: space heating at 24.5–120 MBH input with a DHW side firing 24.5–199 MBH, delivering 5.2 GPM at a 70°F rise at 95.3% AFUE on the wall-hung stainless platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.6 %

The Peerless Series MI-e MI-e-03 is the smallest size of the 84%-class cast-iron gas water line: a fixed 70 MBH input for 60 MBH heating capacity and a 52 MBH net water rating at 84.6% AFUE, with 4.72 US gallons of boiler water content, on the Hydrostat IC natural-draft platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.6 %

The Peerless Series MI-e MI-e-04 is a 105 MBH mid-small size of the 84%-class cast-iron gas water line: a fixed 105 MBH input for 89 MBH heating capacity and a 77 MBH net water rating at 84.6% AFUE, with 6 US gallons of boiler water content, on the Hydrostat IC natural-draft platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.5 %

The Peerless Series MI-e MI-e-05 is a 140 MBH mid size of the 84%-class cast-iron gas water line: a fixed 140 MBH input for 119 MBH heating capacity and a 103 MBH net water rating at 84.5% AFUE, with 7.28 US gallons of boiler water content, on the Hydrostat IC natural-draft platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.4 %

The Peerless Series MI-e MI-e-06 is a 175 MBH mid-large size of the 84%-class cast-iron gas water line: a fixed 175 MBH input for 148 MBH heating capacity and a 129 MBH net water rating at 84.4% AFUE, with 8.56 US gallons of boiler water content, on the Hydrostat IC natural-draft platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.4 %

The Peerless Series MI-e MI-e-07 is a 210 MBH large size of the 84%-class cast-iron gas water line: a fixed 210 MBH input for 178 MBH heating capacity and a 155 MBH net water rating at 84.4% AFUE, with 9.84 US gallons of boiler water content, on the Hydrostat IC natural-draft platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.3 %

The Peerless Series MI-e MI-e-08 is a 245 MBH large size of the 84%-class cast-iron gas water line: a fixed 245 MBH input for 207 MBH heating capacity and a 180 MBH net water rating at 84.3% AFUE, with 11.12 US gallons of boiler water content, on the Hydrostat IC natural-draft platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.3 %

The Peerless Series MI-e MI-e-09 is the largest MI-e of the 84%-class cast-iron gas water line: a fixed 280 MBH input for 236 MBH heating capacity and a 205 MBH net water rating at 84.3% AFUE, with 12.4 US gallons of boiler water content, on the Hydrostat IC natural-draft platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series MI MI-03

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The Peerless Series MI MI-03 is the smallest Series MI size of the legacy cast-iron gas water line: 70 MBH fixed input for 58 MBH heating capacity and a 50 MBH net water rating at 82.2% AFUE, with 4.72 US gallons of boiler water content, on the natural-draft chimney platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series MI MI-04

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
82.1 %

The Peerless Series MI MI-04 is a 105 MBH mid-small size of the legacy cast-iron gas water line: 105 MBH fixed input for 86 MBH heating capacity and a 75 MBH net water rating at 82.1% AFUE, with 6 US gallons of boiler water content, on the natural-draft chimney platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series MI MI-05

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Peerless Series MI MI-05 is a 140 MBH mid size of the legacy cast-iron gas water line: 140 MBH fixed input for 115 MBH heating capacity and a 100 MBH net water rating at 82% AFUE, with 7.28 US gallons of boiler water content, on the natural-draft chimney platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series MI MI-06

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Peerless Series MI MI-06 is a 175 MBH mid-large size of the legacy cast-iron gas water line: 175 MBH fixed input for 143 MBH heating capacity and a 124 MBH net water rating at 82% AFUE, with 8.56 US gallons of boiler water content, on the natural-draft chimney platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series MI MI-07

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Peerless Series MI MI-07 is a 195 MBH large size of the legacy cast-iron gas water line: 195 MBH fixed input for 160 MBH heating capacity and a 139 MBH net water rating at 82% AFUE, with 9.84 US gallons of boiler water content, on the natural-draft chimney platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series MI MI-08

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Peerless Series MI MI-08 is a 227.5 MBH large size of the legacy cast-iron gas water line: 227.5 MBH fixed input for 186 MBH heating capacity and a 162 MBH net water rating at 82% AFUE, with 11.12 US gallons of boiler water content, on the natural-draft chimney platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series MI MI-09

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Peerless Series MI MI-09 is the largest Series MI size of the legacy cast-iron gas water line: 260 MBH fixed input for 211 MBH heating capacity and a 183 MBH net water rating at 82% AFUE, with 12.4 US gallons of boiler water content, on the natural-draft chimney platform.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
84.1 %

The Peerless Series MIHII MIHII-03 is the smallest Series MIHII size of the legacy mid-efficiency cast-iron gas water line: 65 MBH fixed input for 55 MBH heating capacity and a 48 MBH net water rating at 84.1% AFUE, with 4.72 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only
DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
84.1 %

The Peerless Series MIHII MIHII-04 is a 97.5 MBH mid-small size of the legacy mid-efficiency cast-iron gas water line: 97.5 MBH fixed input for 82 MBH heating capacity and a 71 MBH net water rating at 84.1% AFUE, with 6 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only
DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Peerless Series MIHII MIHII-05 is a 130 MBH mid size of the legacy mid-efficiency cast-iron gas water line: 130 MBH fixed input for 110 MBH heating capacity and a 96 MBH net water rating at 84% AFUE, with 7.28 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only
DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Peerless Series MIHII MIHII-06 is the largest Series MIHII size of the legacy mid-efficiency cast-iron gas water line: 162.5 MBH fixed input for 137 MBH heating capacity and a 119 MBH net water rating at 84% AFUE, with 8.56 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only

Peerless Boilers

Peerless Cast 92-2

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
90 %

The Peerless Cast 92-2 is the legacy residential gas-fired condensing cast-iron boiler: a single-model line with a 40–199 MBH CSA input range whose 199 MBH rating row prints 184 MBH output and a 148 MBH net rating at 90% AFUE (ENERGY STAR certified), sealed-combustion direct vent with a 3" flue, 4.75 gallons of water and a HeatNet text-display control.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Cast 92-4

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Cast 92-4 is the legacy commercial or large-residential gas-fired condensing cast-iron boiler: a single-model line with an 80–399 MBH CSA input range whose 399 MBH rating row prints 370 MBH output and a 322 MBH net rating at 92.7% thermal efficiency (87.7% combustion efficiency), sealed-combustion direct vent with a 4" flue, 7.125 gallons of water and a cascade-ready HeatNet control.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series CC CC-03

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-03 is a current commercial cast-iron steam or hot water boiler firing 375 MBH gas (2.6 GPH oil) for 308 MBH gross output, a 231 MBH net steam rating (963 sq ft) and a 268 MBH net water rating at 82.1% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-04

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-04 is a current commercial cast-iron steam or hot water boiler firing 520 MBH gas (3.6 GPH oil) for 421 MBH gross output, a 316 MBH net steam rating (1316 sq ft) and a 366 MBH net water rating at 81.5% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-05

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-05 is a current commercial cast-iron steam or hot water boiler firing 722 MBH gas (5 GPH oil) for 587 MBH gross output, a 441 MBH net steam rating (1725 sq ft) and a 540 MBH net water rating at 81.3% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-06

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-06 is a current commercial cast-iron steam or hot water boiler firing 938 MBH gas (6.5 GPH oil) for 762 MBH gross output, a 572 MBH net steam rating (2382 sq ft) and a 663 MBH net water rating at 81.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-07

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-07 is a current commercial cast-iron steam or hot water boiler firing 1140 MBH gas (7.9 GPH oil) for 924 MBH gross output, a 694 MBH net steam rating (2888 sq ft) and a 803 MBH net water rating at 81.1% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-08

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-08 is a current commercial cast-iron steam or hot water boiler firing 1342 MBH gas (9.3 GPH oil) for 1087 MBH gross output, a 815 MBH net steam rating (3398 sq ft) and a 945 MBH net water rating at 81% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-09

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-09 is a current commercial cast-iron steam or hot water boiler firing 1559 MBH gas (10.8 GPH oil) for 1262 MBH gross output, a 947 MBH net steam rating (3947 sq ft) and a 1097 MBH net water rating at 83.5% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-10

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-10 is a current commercial cast-iron steam or hot water boiler firing 1761 MBH gas (12.2 GPH oil) for 1424 MBH gross output, a 1081 MBH net steam rating (4506 sq ft) and a 1238 MBH net water rating at 83.4% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-11

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-11 is a current commercial cast-iron steam or hot water boiler firing 1963 MBH gas (13.6 GPH oil) for 1587 MBH gross output, a 1217 MBH net steam rating (5071 sq ft) and a 1380 MBH net water rating at 83.4% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Peerless Boilers

Peerless Series CC CC-12

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series CC CC-12 is a current commercial cast-iron steam or hot water boiler firing 2165 MBH gas (15 GPH oil) for 1750 MBH gross output, a 1352 MBH net steam rating (5635 sq ft) and a 1522 MBH net water rating at 83.4% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84.2 %

The Peerless Series GM GM-e-05 is a current semi-commercial cast-iron gas boiler firing 214.5 MBH for 182 MBH heating capacity and a 158 MBH net water rating at 84.2% AFUE, in a natural-draft chimney package sized for single, multiple or modular installations.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Peerless Series GM GM-e-06 is a current semi-commercial cast-iron gas boiler firing 268 MBH for 226 MBH heating capacity and a 197 MBH net water rating at 84% AFUE, in a natural-draft chimney package sized for single, multiple or modular installations.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series GM GM-07

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series GM GM-07 is a current semi-commercial cast-iron gas boiler firing 342 MBH for 275 MBH gross output and a 239 MBH net water rating at 80.3% thermal efficiency, in a natural-draft chimney package sized for single, multiple or modular installations.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless Series GM GM-08

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series GM GM-08 is a current semi-commercial cast-iron gas boiler firing 399 MBH for 320 MBH gross output and a 278 MBH net water rating at 80.3% thermal efficiency, in a natural-draft chimney package sized for single, multiple or modular installations.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-04 is a current commercial cast-iron steam or hot water boiler firing 1143 MBH gas (7.9 GPH oil) for 931 MBH gross output, a 698 MBH net steam rating (2908 sq ft) and a 810 MBH net water rating at 81.4% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-05 is a current commercial cast-iron steam or hot water boiler firing 1458 MBH gas (10.2 GPH oil) for 1194 MBH gross output, a 896 MBH net steam rating (3733 sq ft) and a 1038 MBH net water rating at 81.9% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-06 is a current commercial cast-iron steam or hot water boiler firing 1773 MBH gas (12.2 GPH oil) for 1458 MBH gross output, a 1110 MBH net steam rating (4625 sq ft) and a 1268 MBH net water rating at 82.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-07 is a current commercial cast-iron steam or hot water boiler firing 2088 MBH gas (14.4 GPH oil) for 1722 MBH gross output, a 1330 MBH net steam rating (5542 sq ft) and a 1497 MBH net water rating at 82.5% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-08 is a current commercial cast-iron steam or hot water boiler firing 2403 MBH gas (16.6 GPH oil) for 1985 MBH gross output, a 1541 MBH net steam rating (6421 sq ft) and a 1726 MBH net water rating at 82.6% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-09 is a current commercial cast-iron steam or hot water boiler firing 2718 MBH gas (18.8 GPH oil) for 2249 MBH gross output, a 1745 MBH net steam rating (7275 sq ft) and a 1956 MBH net water rating at 82.7% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-10 is a current commercial cast-iron steam or hot water boiler firing 3033 MBH gas (21 GPH oil) for 2513 MBH gross output, a 1951 MBH net steam rating (8129 sq ft) and a 2185 MBH net water rating at 82.8% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-11 is a current commercial cast-iron steam or hot water boiler firing 3348 MBH gas (23 GPH oil) for 2776 MBH gross output, a 2155 MBH net steam rating (8979 sq ft) and a 2414 MBH net water rating at 82.9% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-12 is a current commercial cast-iron steam or hot water boiler firing 3663 MBH gas (25.5 GPH oil) for 3040 MBH gross output, a 2360 MBH net steam rating (9833 sq ft) and a 2643 MBH net water rating at 83% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-13 is a current commercial cast-iron steam or hot water boiler firing 3978 MBH gas (27.5 GPH oil) for 3304 MBH gross output, a 2565 MBH net steam rating (10688 sq ft) and a 2873 MBH net water rating at 83% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-14 is a current commercial cast-iron steam or hot water boiler firing 4293 MBH gas (29.5 GPH oil) for 3567 MBH gross output, a 2769 MBH net steam rating (11538 sq ft) and a 3102 MBH net water rating at 83.1% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-15 is a current commercial cast-iron steam or hot water boiler firing 4608 MBH gas (32 GPH oil) for 3851 MBH gross output, a 2974 MBH net steam rating (12392 sq ft) and a 3331 MBH net water rating at 83.1% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-16 is a current commercial cast-iron steam or hot water boiler firing 4923 MBH gas (34 GPH oil) for 4095 MBH gross output, a 3179 MBH net steam rating (13246 sq ft) and a 3561 MBH net water rating at 83.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-17 is a current commercial cast-iron steam or hot water boiler firing 5238 MBH gas (36.5 GPH oil) for 4358 MBH gross output, a 3384 MBH net steam rating (14100 sq ft) and a 3790 MBH net water rating at 83.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Peerless Series TCII TCII-18 is a current commercial cast-iron steam or hot water boiler firing 5553 MBH gas (38.5 GPH oil) for 4622 MBH gross output, a 3589 MBH net steam rating (14954 sq ft) and a 4019 MBH net water rating at 83.2% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Services

ROMA services for Peerless Boilers boilers

On-site service in Greater Vancouver. Brand and model context is kept when you request service.

Error codes and alerts

Peerless Boilers error codes

Documented meanings resolved against the specific series, controller and manual version. A code is not a diagnosis.

Full Peerless Boilers error-code index →

Manuals and documents

Official documentation

Links go to the manufacturer's own documents. Boilers.ca does not reproduce manuals.

Frequently asked questions

Are Peerless boilers available in Canada?

No official statement of Canadian sales or distribution was found on the official pages checked on September 9, 2026, so Boilers.ca records canadianStatus 'unknown'. This brand page documents the equipment for information and service planning.

Which Peerless series does Boilers.ca document?

Thirteen gas series records: PureFire (PF-50–PF-399), Series PBC (PBC-34/40/52), Series MI-e (MI-e-03–MI-e-09), Series MI (MI-03–MI-09), Series MIHII (MIHII-03–MIHII-06) and Cast 92 (92-2/92-4) at model level; plus the Series 63/63-x, PSCII and DE hubs and the legacy Series LC/LCE and current commercial Series CC, GM and TCII hubs. Model-level pages are published for PureFire, PBC, MI-e, MI, MIHII and Cast 92.

Why does Boilers.ca not publish Peerless Pinnacle or WB90 series pages?

The official Pinnacle product page describes the Pinnacle as Peerless' oil-fired condensing residential boiler and the WB90 page describes an oil-fired residential boiler with a flame-retention burner — both grouped under 'Out of Circulation'. Boilers.ca documents gas-fired equipment, so those pages would mislabel the products' fuel; they stay unpublished.

Need help with a Peerless Boilers boiler?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate