Boiler parts
Every boiler part — matched to the model, tied to the repair
65 documented components and counting: what each part does, how it fails, the alerts it triggers, and the ROMA service that puts it right across Greater Vancouver.
Search a part, a symptom or the alert text on the display — every result is traced to official documentation.
How it works
Diagnose the part, then let ROMA fit it
A part page is not a shopping cart — it is the same reference a technician uses, tied directly to the services that do the work.
01
Find your boiler
Model and serial from the rating plate, or the alert text on the display. The series pages carry verified specifications and official manuals.
02
Identify the part
The documented alert and the part page symptoms point to the component — flame sensor, circulator, gas valve, control board, sensor or seal.
03
Repair or replace
ROMA confirms the part against your exact series, orders what matches, and completes the repair — or quotes the replacement when repair no longer makes sense.
Parts
Water & hydronics
25 documented components in this group.
Circulator pump
The circulator is the pump that moves heated water from a boiler out to the radiators, baseboards or in-floor loops and back again. This page covers w…
What it does, how it fails →Expansion tank
An expansion tank gives heating water somewhere safe to go as it heats and grows, keeping pressure stable and protecting the relief valve. This page e…
What it does, how it fails →Zone valve
A zone valve lets one boiler heat several areas at different temperatures by opening or closing the water flow to each zone on demand. This page cover…
What it does, how it fails →Heat exchanger
The heat exchanger is where a boiler transfers heat from the burner flame to the water that heats your home. This page explains how condensing heat ex…
What it does, how it fails →Pressure relief valve
The pressure relief valve is a boiler's last line of defence: if system pressure ever exceeds the boiler's rating, the valve opens and discharges wate…
What it does, how it fails →Air separator (automatic air eliminator)
An air separator — also called an automatic air eliminator — removes the tiny air bubbles that form as heating water warms, protecting a hydronic syst…
What it does, how it fails →Automatic air vent
An automatic air vent is a float-operated valve that lets air escape from a heating system by itself and closes the moment water arrives, so air leave…
What it does, how it fails →Backflow preventer (make-up water)
A backflow preventer on the boiler's make-up water line guarantees that heating water — which holds corrosion inhibitors and sits in a closed loop — c…
What it does, how it fails →Mixing valve (system temperature)
A mixing valve blends hot boiler water with cooler water so one boiler can serve parts of a system at different temperatures — warm floors, radiators,…
What it does, how it fails →Thermostatic radiator valves (TRVs)
A thermostatic radiator valve is a self-acting valve on an individual radiator that holds that room at its own temperature, without electricity or ext…
What it does, how it fails →Low-water cutoff
A low-water cutoff is the safety device that stops a boiler from firing when there is not enough water inside it. This page explains how the cutoff wo…
What it does, how it fails →Flow switch
A flow switch proves that water is actually moving through the boiler before it fires and while it runs. This page explains where flow switches are us…
What it does, how it fails →System feeder / auto fill valve
A system feeder, also called an automatic fill valve, keeps a hydronic system topped up by admitting make-up water through a pressure-reducing valve. …
What it does, how it fails →Y-strainer
A Y-strainer is a small screen in a Y-shaped fitting that catches debris on the boiler return before it reaches the heat exchanger and pump. This page…
What it does, how it fails →Magnetic dirt separator
A magnetic dirt separator removes iron oxide sludge and other debris from heating water before it can coat the heat exchanger. This page explains what…
What it does, how it fails →Hydraulic separator
A hydraulic separator de-couples the boiler loop from the system loop so each side can run at its own flow rate. This page explains what a hydraulic s…
What it does, how it fails →Buffer tank
A buffer tank adds water volume to a hydronic system so a modulating boiler can run without short cycling. This page explains when buffer tanks are us…
What it does, how it fails →Differential-pressure bypass valve
A differential-pressure bypass valve opens when system pressure rises — usually because zone valves have closed — so the boiler keeps enough flow to r…
What it does, how it fails →Isolation / service valve
Isolation valves are the full-port shutoffs at the boiler's supply and return that let a technician service the boiler without draining the whole syst…
What it does, how it fails →Pressure gauge
The pressure gauge is the boiler's dashboard: it shows the water pressure in the system, and often the temperature too. This page explains what the ga…
What it does, how it fails →Plate heat exchanger
A plate heat exchanger is a stack of corrugated stainless plates that transfers heat between two water circuits — most often from boiler water to dome…
What it does, how it fails →DHW mixing valve
A DHW mixing valve blends cold water with hot to deliver domestic hot water at a safe, steady temperature. This page explains where mixing valves are …
What it does, how it fails →Zone valve actuator
A zone valve actuator is the motorized head that opens and closes a zone valve when a thermostat calls for heat. This page explains how actuators work…
What it does, how it fails →Pump flange set
A pump flange set is the pair of flanged fittings — often with isolation valves built in — that connect a circulator to the boiler piping and make the…
What it does, how it fails →Balancing valve
A balancing valve is an adjustable valve that sets the flow through each part of a hydronic system so every zone gets the heat it was designed for. Th…
What it does, how it fails →
Parts
Gas, ignition & combustion
19 documented components in this group.
Ignition electrode
The ignition electrode creates the spark that lights the burner in a gas boiler, and on many models it also senses the flame once it is burning. This …
What it does, how it fails →Gas valve
The gas valve is the boiler's controlled gateway for gas: it opens only when the control has proven safe conditions, meters the fuel to the burner, an…
What it does, how it fails →Flame sensor (flame rod)
The flame sensor is the small rod that proves a gas boiler's burner is actually lit before the control will keep the gas valve open. This page explain…
What it does, how it fails →Combustion fan (blower)
The combustion fan is the sealed boiler's lungs: it draws in combustion air, keeps the burner's gas-air mixture correct, and pushes flue gases out thr…
What it does, how it fails →Hot-surface igniter
A hot-surface igniter is a ceramic element that glows white-hot to light the burner in a gas boiler, and on many designs it doubles as the flame senso…
What it does, how it fails →Burner assembly
The burner assembly is where gas and air meet and burn inside a boiler, and its condition decides whether combustion is clean or makes carbon monoxide…
What it does, how it fails →Gas orifice
A gas orifice is the precisely sized opening that meters gas into each burner, and its size must match the fuel and altitude the boiler was set up for…
What it does, how it fails →Appliance gas regulator
The appliance gas regulator is the diaphragm device that holds gas pressure steady as it reaches the boiler, so the burner always receives fuel at the…
What it does, how it fails →Gas pressure switch
A gas pressure switch proves that gas pressure at the boiler is within a safe range before the burner is allowed to fire, and it shuts the burner down…
What it does, how it fails →Air pressure switch
An air pressure switch proves that the combustion fan is moving air and that the vent path is clear before the boiler is allowed to fire. This page ex…
What it does, how it fails →Thermocouple
A thermocouple is the small probe that sits in a standing pilot flame and generates the tiny voltage that holds the gas valve open, shutting the gas o…
What it does, how it fails →Thermopile
A thermopile, sometimes called a pilot generator or powerpile, is a stack of thermocouples that makes enough voltage to run a millivolt gas valve with…
What it does, how it fails →Pilot assembly
A pilot assembly is the small burner, orifice, igniter and flame sensor that lights the main burner on older gas boilers. This page explains standing …
What it does, how it fails →Flame rollout switch
A flame rollout switch is a one-time safety device that shuts a boiler down when flame or hot gas escapes the combustion chamber instead of passing th…
What it does, how it fails →Spill switch / blocked-vent switch
A spill switch, also called a blocked-vent switch, shuts down an atmospheric boiler when flue gases spill from the draft hood instead of rising up the…
What it does, how it fails →High-limit switch
A high-limit switch shuts the burner off when boiler water gets hotter than it should, protecting the heat exchanger and the system from overheating. …
What it does, how it fails →Flue damper
A flue damper is a motorized blade in the vent connector of an atmospheric boiler that closes when the burner is off to stop heat escaping up the chim…
What it does, how it fails →Vent terminal
The vent terminal is where a boiler's exhaust and combustion-air pipes meet the outdoors, and keeping it clear is one of the few combustion tasks a ho…
What it does, how it fails →Concentric vent kit
A concentric vent kit runs a condensing boiler's exhaust and combustion air through one pipe-within-a-pipe and one wall or roof penetration, using onl…
What it does, how it fails →
Parts
Controls & sensors
12 documented components in this group.
Boiler sensors (thermistors)
Boiler sensors are small temperature probes, usually thermistors, that tell the control how hot the water and flue gases are so it can fire safely and…
What it does, how it fails →Outdoor reset sensor
An outdoor reset sensor reads the outside temperature so a boiler's control can match the water temperature it sends out to the weather — milder days …
What it does, how it fails →Zone control panel and relays
A zone control panel is the switching brain of a multi-zone hydronic system: it reads each thermostat, opens the right zone valves or starts the right…
What it does, how it fails →Aquastat (water temperature controller)
An aquastat is the water temperature controller that has governed boilers for decades: it watches the boiler water temperature and switches the burner…
What it does, how it fails →Control board / PCB
The control board — also called the PCB, or printed circuit board — is the boiler's main computer. It reads the sensors and safety switches, sequences…
What it does, how it fails →User interface / display
The user interface — the front panel display or touchscreen — is how you and your technician see what the boiler is doing. It shows water temperature,…
What it does, how it fails →Transformer
The transformer is the small component inside the boiler that steps household 120-volt power down to the low voltage the controls use — typically 24 v…
What it does, how it fails →Thermistor / NTC sensor
A thermistor is the small temperature probe — technically a negative temperature coefficient, or NTC, resistor — that tells a boiler's control how hot…
What it does, how it fails →Room thermostat
The room thermostat is the switch that tells a heating zone to call for heat, and on a modern boiler it is also part of the control system's wiring. T…
What it does, how it fails →Sensor well / immersion well
A sensor well — also called an immersion well — is the metal pocket that holds a temperature probe in contact with the water or flue gases it is measu…
What it does, how it fails →Ignition cable
The ignition cable carries the high-voltage spark from the boiler's ignition module or transformer to the electrode at the burner. A cable that is loo…
What it does, how it fails →Water pressure sensor
The water pressure sensor is the electronic gauge that tells a modern boiler's control how much pressure the heating loop is under. It replaces the me…
What it does, how it fails →
Parts
Venting & condensate
5 documented components in this group.
Condensate trap
Every condensing boiler makes acidic water as it cools its flue gases, and the condensate trap collects that water and seals the flue gases out of the…
What it does, how it fails →Boiler venting (flue and air intake)
A condensing boiler vents cool, wet flue gases through dedicated plastic pipe that must meet ULC S636 in Canada and the boiler manufacturer's own rule…
What it does, how it fails →Condensate pump
A condensate pump is the small collection pump that lifts the acidic water a condensing boiler produces up to a drain when gravity drainage is not pos…
What it does, how it fails →Condensate neutralizer
A condensate neutralizer is a canister of alkaline media — marble, lime or phosphate chips — that raises the pH of the acidic water a condensing boile…
What it does, how it fails →Flue temperature sensor
The flue temperature sensor — sometimes called the stack or exhaust sensor — measures how hot the gases leaving the boiler are. It protects the ventin…
What it does, how it fails →
Parts
DHW & combi
3 documented components in this group.
DHW flow sensor
On a combi boiler, the DHW flow sensor is the component that notices a hot-water tap has been opened and tells the boiler to switch from space heating…
What it does, how it fails →Diverting valve / combi diverter
The diverting valve — a three-way valve on a combi boiler — steers the boiler's heat between the heating system and the domestic hot water circuit. Wh…
What it does, how it fails →DHW plate heat exchanger
The DHW plate heat exchanger is the stainless-steel block inside a combi boiler that transfers heat from the boiler's water to the domestic hot water …
What it does, how it fails →
Parts
More parts
1 documented component in this group.
Parts and your service
The part is only half the job
Every part on this site is documented so the repair can be done once, correctly — and so replacement decisions are made on evidence, not guesswork.
- Repairs: diagnosis by testing, the matching part, and a verified heating cycle before we leave.
- Replacements: when parts and labour stop making sense, a sized replacement quote with permits and commissioning.
- Maintenance: the annual service that keeps parts from failing early — and keeps warranties intact.
If you smell gas
- Stop what you are doing. Do not use phones, switches, matches or anything that can spark inside.
- Go outside and leave the door open behind you.
- Call the FortisBC 24-hour emergency line at 1-800-663-9911 or dial 911.
Only after that, call ROMA about the boiler. Official guidance: FortisBC gas leaks and odour.
Frequently asked questions
Can I buy the part and install it myself?
Gas-side work — anything touching the gas valve, burner, ignition or combustion path — is regulated work in British Columbia and must be done by a licensed gas contractor. Water-side parts can often be replaced by a plumber or the homeowner, but a wrong part or a bad seal can flood or air-lock the system, so diagnosis first is always cheaper.
How do I know which part my boiler needs?
Start with the model and serial numbers from the rating plate, then the alert text on the display. Every error code on Boilers.ca is traced to the exact controller and manual, and each part page explains the failure symptoms it produces. Bring both to the call and the technician arrives with the right part in mind.
Does ROMA supply parts for brands not listed here?
ROMA repairs most gas boiler brands in Greater Vancouver. If your brand or model is not yet documented on Boilers.ca, call 778-909-5731 with the rating-plate details — the catalogue is growing, and the service work does not wait for it.
Is a replacement part the same as an original part?
Not always. Manufacturers revise parts over a product's life, and some components are superseded by updated kits. The documented series and model on this site tells the technician which generation of the part your boiler was built around, so the replacement matches what is actually installed.
Not sure which part you need?
Describe the symptom or read the alert from the display — ROMA diagnoses the part and does the work across Greater Vancouver.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.