- Input
- —
- Output (max)
- 80 MBH
- AFUE
- Gas 85.5% / Oil 88%
The De Dietrich GT 123A is a 3-section eutectic cast-iron 3-pass boiler rated 94 MBH gas input / 80 MBH output (0.65 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 98 MBH
- AFUE
- Gas 85.5% / Oil 88%
The De Dietrich GT 124A is a 4-section eutectic cast-iron 3-pass boiler rated 115 MBH gas input / 98 MBH output (0.8 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 122 MBH
- AFUE
- Gas 85.5% / Oil 88%
The De Dietrich GT 125A is a 5-section eutectic cast-iron 3-pass boiler rated 144 MBH gas input / 122 MBH output (1 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 141 MBH
- AFUE
- Gas 85.5% / Oil 88%
The De Dietrich GT 126A is a 6-section eutectic cast-iron 3-pass boiler rated 166 MBH gas input / 141 MBH output (1.15 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 147 MBH
- AFUE
- —
The De Dietrich GT 224A is a 4-section eutectic cast-iron 3-pass commercial boiler rated 173 MBH gas input / 147 MBH output (1.2 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with R1 1/4 supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 190 MBH
- AFUE
- —
The De Dietrich GT 225A is a 5-section eutectic cast-iron 3-pass commercial boiler rated 224 MBH gas input / 190 MBH output (1.55 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with R1 1/4 supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 233 MBH
- AFUE
- —
The De Dietrich GT 226A is a 6-section eutectic cast-iron 3-pass commercial boiler rated 274 MBH gas input / 233 MBH output (1.9 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with R1 1/2 supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 276 MBH
- AFUE
- —
The De Dietrich GT 227A is a 7-section eutectic cast-iron 3-pass commercial boiler rated 324 MBH gas input / 276 MBH output (2.25 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with R1 1/2 supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 307 MBH
- AFUE
- —
The De Dietrich GT 228A is a 8-section eutectic cast-iron 3-pass commercial boiler rated 361 MBH gas input / 307 MBH output (2.5 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with R1 1/2 supply and return connections.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 344 MBH
- AFUE
- —
The De Dietrich GT 334A is a 4-section eutectic cast-iron 3-pass commercial boiler rated 404 MBH gas input / 344 MBH output (2.8 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" threaded female supply and return.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 510 MBH
- AFUE
- —
The De Dietrich GT 335A is a 5-section eutectic cast-iron 3-pass commercial boiler rated 598 MBH gas input / 510 MBH output (4.15 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" threaded female supply and return.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 688 MBH
- AFUE
- —
The De Dietrich GT 336A is a 6-section eutectic cast-iron 3-pass commercial boiler rated 808 MBH gas input / 688 MBH output (5.6 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" welded pipe with distributor tube supply and return.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 872 MBH
- AFUE
- —
The De Dietrich GT 337A is a 7-section eutectic cast-iron 3-pass commercial boiler rated 1024 MBH gas input / 872 MBH output (7.1 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" welded pipe with distributor tube supply and return.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 1,044 MBH
- AFUE
- —
The De Dietrich GT 338A is a 8-section eutectic cast-iron 3-pass commercial boiler rated 1226 MBH gas input / 1044 MBH output (8.5 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" welded pipe with distributor tube supply and return.
Natural gasPropaneDHW: unknown
- Input
- —
- Output (max)
- 1,229 MBH
- AFUE
- —
The De Dietrich GT 339A is a 9-section eutectic cast-iron 3-pass commercial boiler rated 1442 MBH gas input / 1229 MBH output (10 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" welded pipe with distributor tube supply and return.
Natural gasPropaneDHW: unknown
- Input
- 34–156 MBH
- Output (max)
- 146 MBH
- AFUE
- —
The De Dietrich MCA Pro 45 is a condensing wall-hung boiler rated 34–156 MBH input and 33–146 MBH output at 94.0% CSA thermal efficiency, with 1-1/4" heating connections and a 117 lb dry weight.
Natural gasPropaneDHW: unknown
- Input
- 34–235 MBH
- Output (max)
- 222 MBH
- AFUE
- —
The De Dietrich MCA Pro 65 is a condensing wall-hung boiler rated 34–235 MBH input and 45–222 MBH output at 94.0% CSA thermal efficiency, with 1-1/4" heating connections and a 133 lb dry weight.
Natural gasPropaneDHW: unknown
- Input
- 55–326 MBH
- Output (max)
- 306 MBH
- AFUE
- —
The De Dietrich MCA Pro 90 is a condensing wall-hung boiler rated 55–326 MBH input and 54–306 MBH output at 94.0% CSA thermal efficiency, with 1-1/4" heating connections and a 148 lb dry weight.
Natural gasPropaneDHW: unknown
- Input
- 82–399 MBH
- Output (max)
- 368 MBH
- AFUE
- —
The De Dietrich MCA Pro 115 is a condensing wall-hung boiler rated 82–399 MBH input and 79–368 MBH output at 94.0% CSA thermal efficiency, with 1-1/4" heating connections and a 150 lb dry weight.
Natural gasPropaneDHW: unknown