New Yorker Boiler boilers in Canada

New Yorker Boiler is an American hydronic-heating manufacturer publishing from newyorkerboiler.com and documenting its products from Lancaster, Pennsylvania. Boilers.ca documents its current gas-fired line-up — the GHE-II condensing heating boiler and GHE-II Combi, the cast-iron CG-F water series, the CGS-C steam series and the power-vented PVCG-C water series — at model level from the published rating tables.

Canadian status unknownHQ: Lancaster, Pennsylvania, United States

At a glance

Official site
Global site
Country
United States
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Documented series
5
Documented models
32

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

About New Yorker Boiler

New Yorker Boiler publishes from newyorkerboiler.com and describes itself on the official site as a manufacturer of reliable residential hydronic-heating products offering a complete line of cast iron and steel boilers plus an indirect water heater, with gas-fired water and steam boilers, oil-fired water or steam boilers and a new ENERGY STAR certified high-efficiency condensing boiler. The product data sheets and I&O manuals are published with a Lancaster, Pennsylvania copyright line. No official statement of Canadian sales or distribution was found on the official pages, so Boilers.ca records canadianStatus 'unknown'.

Boilers.ca documents the current gas line-up from the official product pages, product specifications and manuals (verified September 9, 2026). The GHE-II condensing family is split into the heating-only models GHE2-080, GHE2-120B, GHE2-150 and GHE2-180 and the combi models GHE2C-136B and GHE2C-200, all 95.0% AFUE on a 316L stainless-steel heat exchanger with a 2-inch vent connection. The cast-iron chimney-vented CG-F water series (CG20F through CG90F, 84.0% AFUE) and CGS-C steam series (CGS30C through CGS80C, 82.0–82.2% AFUE) are documented at model level, as is the power-vented PVCG-C water series (twelve natural-gas and LP SKUs from PVCG30C to PVCG80C, 84–85% AFUE).

The site also lists oil-fired lines (CL water and steam, CI-HGS, AP-U, FR and FR-HGS) and an indirect water heater under the same Tech & Lit index; because Boilers.ca documents gas-fired equipment and never repurposes a series for the wrong fuel, no oil series pages are published for New Yorker. Gas work on any installed New Yorker boiler belongs with a licensed contractor working from the manual for the unit's own series.

Series

New Yorker Boiler boiler series

Each series hub lists its models, verified specifications, manuals and documented alerts.

  • GHE-II

    current

    The New Yorker GHE-II is the brand's 95% AFUE condensing gas heating boiler: four heating-only sizes GHE2-080 through GHE2-180 covering 8–80 to 20–180 MBH input with a 316L stainless-steel heat exchanger, automatic no-touch combustion setup, sensor-less rate-based reset and a 2-inch direct-vent connection.

    condensingNatural gasPropane95% AFUE

    4 models, specs and manuals →

  • The New Yorker GHE-II Combi is the condensing combination version of the GHE-II: models GHE2C-136B (13.6–120 MBH heating input, DHW to 136 MBH, 3.7 GPM at a 70°F rise) and GHE2C-200 (20–150 MBH heating, DHW to 200 MBH, 5.2 GPM), both 95.0% AFUE with a flat-plate DHW heat exchanger and 10:1 DHW turndown.

    combiNatural gasPropane95% AFUE

    2 models, specs and manuals →

  • CG-F

    current

    The New Yorker CG-F is the brand's cast-iron, chimney-vented gas water boiler at 84% AFUE, sold in eight sizes CG20F through CG90F covering 38–280 MBH input with an integrated boiler control featuring the energy-saving thermal purge, integral LWCO and an additional pump relay.

    non-condensingNatural gasPropane84% AFUE

    8 models, specs and manuals →

  • CGS-C

    current

    The New Yorker CGS-C is the brand's gas-fired cast-iron steam boiler, sold fully assembled in six sizes CGS30C through CGS80C covering 69–241 MBH input at up to 82.2% AFUE with a built-in draft diverter, probe-type LWCO and an optional pre-cut near-boiler piping kit.

    non-condensingNatural gasPropane82.2% AFUE

    6 models, specs and manuals →

  • PVCG-C

    current

    The New Yorker PVCG-C is the brand's power-vented, cast-iron gas water boiler for homes without a chimney, sold in twelve natural-gas and LP SKUs from PVCG30CN/P to PVCG80CN/P covering 63–245 MBH input at 84–85% AFUE with an integrated boiler control, factory-installed low water cutoff and thermal purge.

    non-condensingNatural gasPropane85% AFUE

    12 models, specs and manuals →

Models

New Yorker Boiler models with verified specifications

CurrentCanadian status unknown
Input
8–80 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-080 is the smallest GHE-II heating size and the lowest minimum fire in the line: 8–80 MBH heating input with 75 MBH DOE heating capacity and a 65 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-120B is the mid-small size sharing the compact 16.3-inch-deep cabinet: 13.6–120 MBH heating input with 112 MBH DOE heating capacity and a 97 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-150 is the first of the deeper 20.4-inch cabinet sizes: 20–150 MBH heating input with 141 MBH DOE heating capacity and a 123 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-180 is the largest heating-only GHE-II size: 20–180 MBH heating input with 169 MBH DOE heating capacity and a 147 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II Combi GHE2C-136B is the smaller combi with 3.7 GPM DHW delivery at a 70°F rise: space heating at 13.6–120 MBH input with a DHW side firing 13.6–136 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II Combi GHE2C-200 is the larger combi with 5.2 GPM DHW delivery at a 70°F rise: space heating at 20–150 MBH input with a DHW side firing 20–200 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneCombi

New Yorker Boiler

New Yorker CG-F CG20F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG20F is the smallest CG-F size, not for use above 2,000 feet: 38 MBH input with 32 MBH DOE heating capacity and a 28 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 4".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG30F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG30F is the second size sharing the 14-inch cabinet and 4-inch vent: 70 MBH input with 59 MBH DOE heating capacity and a 51 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 4".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG40F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG40F is the third size, stepping to a 5-inch vent: 105 MBH input with 88 MBH DOE heating capacity and a 77 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 5".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG50F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG50F is the mid-size CG-F with a 6-inch vent: 140 MBH input with 117 MBH DOE heating capacity and a 102 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 6".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG60F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG60F is the fifth size, sharing the 6-inch vent with the CG50F: 175 MBH input with 146 MBH DOE heating capacity and a 127 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 6".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG70F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG70F is the first size with a 3/4-inch gas valve and 7-inch vent: 210 MBH input with 176 MBH DOE heating capacity and a 153 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 7".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG80F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG80F is the second-largest CG-F size: 245 MBH input with 205 MBH DOE heating capacity and a 178 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 7".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG90F

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker CG-F CG90F is the largest CG-F size with an 8-inch vent: 280 MBH input with 234 MBH DOE heating capacity and a 203 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 8".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS30C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The New Yorker CGS-C CGS30C is the smallest CGS-C steam size: 69 MBH input with 57 MBH DOE heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, chimney vented with a 4" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS40C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The New Yorker CGS-C CGS40C is the second steam size with a 5-inch flue collar: 103 MBH input with 84 MBH DOE heating capacity and a 63 MBH AHRI net steam rating (263 sq ft) at 82% AFUE, chimney vented with a 5" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS50C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The New Yorker CGS-C CGS50C is the mid-size steam model with a 6-inch flue: 138 MBH input with 113 MBH DOE heating capacity and a 85 MBH AHRI net steam rating (354 sq ft) at 82% AFUE, chimney vented with a 6" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS60C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.1 %

The New Yorker CGS-C CGS60C is the fourth size at 82.1% AFUE: 172 MBH input with 142 MBH DOE heating capacity and a 107 MBH AHRI net steam rating (446 sq ft) at 82.1% AFUE, chimney vented with a 6" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS70C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.1 %

The New Yorker CGS-C CGS70C is the first size with a 7-inch flue collar: 207 MBH input with 171 MBH DOE heating capacity and a 128 MBH AHRI net steam rating (533 sq ft) at 82.1% AFUE, chimney vented with a 7" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS80C

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82.2 %

The New Yorker CGS-C CGS80C is the largest CGS-C at 82.2% AFUE: 241 MBH input with 199 MBH DOE heating capacity and a 149 MBH AHRI net steam rating (621 sq ft) at 82.2% AFUE, chimney vented with a 7" flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG30CN is the smallest PVCG-C size in natural gas: 70 MBH input with 60 MBH heating capacity and a 52 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG30CP is the smallest PVCG-C size in LP gas: 63 MBH input with 54 MBH heating capacity and a 47 MBH net AHRI water rating at 85% AFUE, power vented in 3".

PropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG40CN is the second PVCG-C size in natural gas: 105 MBH input with 90 MBH heating capacity and a 78 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG40CP is the second PVCG-C size in LP gas: 94.5 MBH input with 81 MBH heating capacity and a 70 MBH net AHRI water rating at 85% AFUE, power vented in 3".

PropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG50CN is the mid-size PVCG-C in natural gas: 140 MBH input with 120 MBH heating capacity and a 104 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG50CP is the mid-size PVCG-C in LP gas: 126 MBH input with 108 MBH heating capacity and a 94 MBH net AHRI water rating at 85% AFUE, power vented in 3".

PropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG60CN is the fourth PVCG-C size in natural gas: 175 MBH input with 150 MBH heating capacity and a 130 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG60CP is the fourth PVCG-C size in LP gas: 157.5 MBH input with 135 MBH heating capacity and a 117 MBH net AHRI water rating at 85% AFUE, power vented in 3".

PropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG70CN is the first PVCG-C size with a 3/4-inch gas connection, in natural gas: 210 MBH input with 179 MBH heating capacity and a 156 MBH net AHRI water rating at 85% AFUE, power vented in 3".

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
85 %

The New Yorker PVCG-C PVCG70CP is the first PVCG-C size with a 3/4-inch gas connection, in LP gas: 189 MBH input with 161 MBH heating capacity and a 140 MBH net AHRI water rating at 85% AFUE, power vented in 3".

PropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker PVCG-C PVCG80CN is the largest PVCG-C size with a 4-inch vent, in natural gas: 245 MBH input with 208 MBH heating capacity and a 181 MBH net AHRI water rating at 84% AFUE, power vented in 4".

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The New Yorker PVCG-C PVCG80CP is the largest PVCG-C size with a 4-inch vent, in LP gas: 220.5 MBH input with 187 MBH heating capacity and a 163 MBH net AHRI water rating at 84% AFUE, power vented in 4".

PropaneHeating-only

Services

ROMA services for New Yorker Boiler boilers

On-site service in Greater Vancouver. Brand and model context is kept when you request service.

Error codes and alerts

New Yorker Boiler error codes

Documented meanings resolved against the specific series, controller and manual version. A code is not a diagnosis.

Full New Yorker Boiler error-code index →

Frequently asked questions

Are New Yorker boilers available in Canada?

No official Canadian-sales or distribution statement was found on newyorkerboiler.com when reviewed on September 9, 2026, so Boilers.ca records canadianStatus 'unknown'. This brand page documents the equipment for information and service planning; confirm supply through a licensed distributor.

Which New Yorker series does Boilers.ca document?

Model-level pages for the GHE-II condensing heating boiler (GHE2-080 through GHE2-180), the GHE-II Combi (GHE2C-136B and GHE2C-200), the cast-iron CG-F water series (CG20F–CG90F), the CGS-C steam series (CGS30C–CGS80C) and the power-vented PVCG-C water series (PVCG30CN/P through PVCG80CN/P).

Why are there no New Yorker oil boiler pages?

New Yorker's Tech & Lit index lists oil-fired lines (CL water and steam, CI-HGS, AP-U, FR, FR-HGS), but Boilers.ca documents gas-fired equipment and does not repurpose a series for the wrong fuel, so those lines are not published here.

Need help with a New Yorker Boiler boiler?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate