DiscontinuedHistorically in Canada
- Input
- 16–80 MBH
- Output (max)
- —
- AFUE
- 95 %
The Prestige Solo 80 is the smallest of the current-generation Prestige Solo sizes, firing 16 to 80 MBH at 95% AFUE in the compact 103 lb fire-tube cabinet — the size that replaced the old Solo 60 when the line was updated. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 20–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Prestige Solo 110 fires 20 to 110 MBH at 95% AFUE in the same 103 lb, 19 3/4-inch-wide cabinet as the Solo 80 — historically the best-known Prestige size, spanning the MCBA (gen-1) through CTRLMax generations. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 27.8–153 MBH
- Output (max)
- —
- AFUE
- 95 %
The Prestige Solo 155 modulates from 27.8 to 153 MBH at 95% AFUE — the model number reads 155 but the maximum input is 153 MBH — adding 15 lb and stepping the connections up to 1 1/4" supply/return versus the smaller Solo sizes. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 30.9–170 MBH
- Output (max)
- —
- AFUE
- 95 %
The Prestige Solo 175 fires 30.9 to 170 MBH at 95% AFUE with 157 MBH DOE capacity, keeping the 19 3/4-inch cabinet of the line while growing to 128 lb and 5.3 gallons of water volume. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 43.6–240 MBH
- Output (max)
- —
- AFUE
- 95 %
The Prestige Solo 250 fires 43.6 to 240 MBH at 95% AFUE in the last of the 19 3/4-inch cabinets, rated 222 MBH DOE capacity — and it is one of the two sizes the Prestige Cascade kits are built around. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 72.5–299 MBH
- Output (max)
- —
- AFUE
- 95 %
The Prestige Solo 299 fires 72.5 to 299 MBH at 95% AFUE — the size added in the generation update alongside the 155 — stepping the line up to a 24 7/8-inch cabinet, 4" vent/air piping and 1 1/2" connections. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 72.5–399 MBH
- Output (max)
- —
- AFUE
- 95.1 %
The Prestige Solo 399 is the largest Prestige Solo: 72.5 to 399 MBH of input with 379 MBH DOE capacity, rated on the page at 95.1% thermal efficiency, in the 216 lb large cabinet — the workhorse of the Prestige Cascade kits. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 20–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Excellence 110 is Triangle Tube's Prestige-family combi: 20 to 110 MBH of heating input at 95% AFUE with internal 14-gallon domestic storage, a 210 GPH first-hour rating and 3.0 GPM of continuous DHW at a 70°F rise, in a 190 lb wall-hung cabinet. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- 13.75–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 110S (INS110S) is the smallest Instinct wall solo: 13.75 to 110 MBH of input at 95% AFUE with 8:1 turndown in a 75 lb, 21.75-inch-wide stainless steel fire-tube cabinet. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 19.375–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 155S (INS155S) is the mid-size Instinct wall solo: 19.375 to 155 MBH of input at 95% AFUE with 8:1 turndown, rated 142 MBH DOE capacity and 123 MBH net AHRI. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 24.875–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 199S (INS199S) is the largest Instinct wall solo: 24.875 to 199 MBH of input at 95% AFUE with 8:1 turndown, rated 184 MBH DOE capacity — the heating-only ceiling of the Instinct wall line. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 13.75–110 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 110S floor version (INSFS110S) delivers the same 13.75 to 110 MBH, 95% AFUE ratings as the wall 110S in a free-standing 22 x 41 x 22-inch cabinet at 145 lb. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 19.375–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 155S floor version (INSFS155S) delivers 19.375 to 155 MBH at 95% AFUE in a 157 lb, 22 x 41 x 22-inch floor cabinet, with the same 142 MBH DOE rating as the wall 155S. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 24.875–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 199S floor version (INSFS199S) is the largest heating-only Instinct: 24.875 to 199 MBH at 95% AFUE with 184 MBH DOE capacity in a 169 lb floor cabinet. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 19.375–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 155C (INS155C) is the wall-hung Instinct combi at 155-class size: 19.375 to 155 MBH heating input plus a large plate heat exchanger delivering 4.0 GPM of DHW at a 70°F rise, rated 95% AFUE. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- 24.875–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 199C (INS199C) is the top Instinct wall combi: 24.875 to 199 MBH heating input with 5.3 GPM of DHW at a 70°F rise, rated 95% AFUE in a 130 lb wall cabinet. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- 19.375–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 155C floor combi (INSFS155C) delivers the wall combi's 19.375 to 155 MBH and 4.0 GPM DHW performance in a floor-standing 181 lb cabinet. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- 24.875–199 MBH
- Output (max)
- —
- AFUE
- 95 %
The Instinct 199C floor combi (INSFS199C) is the largest Instinct appliance: 24.875 to 199 MBH at 95% AFUE with 5.3 GPM of DHW at a 70°F rise in a 191 lb floor cabinet. Discontinued with the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- 23–84 MBH
- Output (max)
- —
- AFUE
- 94 %
The Challenger CC85 Solo is the smallest Challenger heating-only boiler, firing 23 to 84 MBH at 94% AFUE with a 3.7:1 turndown — a condensing solo for use with an indirect tank, discontinued years before the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 29–106 MBH
- Output (max)
- —
- AFUE
- 94 %
The Challenger CC105 Solo fires 29 to 106 MBH at 94% AFUE with a 94 MBH DOE capacity — the mid-size Challenger heating-only boiler, confirmed by its CC105 submittal. Discontinued years before the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 33–125 MBH
- Output (max)
- —
- AFUE
- 95 %
The Challenger CC125 Solo fires 33 to 125 MBH at 95% AFUE with a 111 MBH DOE capacity — the second-largest Challenger heating-only boiler, appearing as 'Challenger 125Hs' in the archived comparison table. Discontinued years before the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- 33–145 MBH
- Output (max)
- —
- AFUE
- 92.3 %
The Challenger CC150 Solo is the largest Challenger heating-only boiler: 33 to 145 MBH of input with a 129 MBH DOE capacity, rated 92.3% AFUE in the 2019 comparison table. Discontinued years before the November 3, 2025 cessation.
Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- 94 %
The Challenger CC85 Combi is the smallest 'Two in One' Challenger combi, named in official manuals and parts lists as the bottom of a three-size combi family spanning 84 to 124 MBH. Its individual ratings were not captured in the archived documents. Discontinued years before the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- 29–106 MBH
- Output (max)
- —
- AFUE
- 94 %
The Challenger CC105 Combi is the mid-size 'Two in One' combi: 29 to 106 MBH at 94% AFUE with 2.5 GPM of DHW at a 70°F rise, condensing in both heating and hot-water modes. Discontinued years before the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- 20–125 MBH
- Output (max)
- —
- AFUE
- 95 %
The Challenger CC125 Combi is the largest 'Two in One' combi with a published row: 20 to 125 MBH at 95% AFUE with a 6.3:1 turndown and 3.0 GPM of DHW at a 70°F rise. Discontinued years before the November 3, 2025 cessation.
Natural gasPropaneCombi
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-20 is a discontinued 20-gallon indirect water heater with 8 gallons of boiler water, 12 sq ft of heating surface and a printed first-hour flow of 125 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-30 is a discontinued 30-gallon indirect water heater with 9 gallons of boiler water, 15 sq ft of heating surface and a printed first-hour flow of 140 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-36 is a discontinued 36-gallon indirect water heater with 12 gallons of boiler water, 18 sq ft of heating surface and a printed first-hour flow of 190 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-45 is a discontinued 46-gallon indirect water heater with 8 gallons of boiler water, 20 sq ft of heating surface and a printed first-hour flow of 220 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-60 is a discontinued 56-gallon indirect water heater with 8 gallons of boiler water, 24 sq ft of heating surface and a printed first-hour flow of 410 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-80 is a discontinued 76-gallon indirect water heater with 15 gallons of boiler water, 28 sq ft of heating surface and a printed first-hour flow of 510 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-100 is a discontinued 95-gallon indirect water heater with 25 gallons of boiler water, 34 sq ft of heating surface and a printed first-hour flow of 575 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III TR-120 is a discontinued 119-gallon indirect water heater with 30 gallons of boiler water, 42 sq ft of heating surface and a printed first-hour flow of 650 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III SMART 20 is a discontinued 22-gallon indirect water heater with 5 gallons of boiler water, 11 sq ft of heating surface and a printed first-hour flow of 110 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III SMART 30 is a discontinued 28-gallon indirect water heater with 5 gallons of boiler water, 13 sq ft of heating surface and a printed first-hour flow of 125 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III SMART 40 is a discontinued 36-gallon indirect water heater with 6 gallons of boiler water, 16 sq ft of heating surface and a printed first-hour flow of 170 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III SMART 50 is a discontinued 46-gallon indirect water heater with 8 gallons of boiler water, 20 sq ft of heating surface and a printed first-hour flow of 200 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III SMART 60 is a discontinued 56-gallon indirect water heater with 8 gallons of boiler water, 24 sq ft of heating surface and a printed first-hour flow of 370 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III SMART 80 is a discontinued 70-gallon indirect water heater with 14 gallons of boiler water, 29 sq ft of heating surface and a printed first-hour flow of 435 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
- Input
- —
- Output (max)
- —
- AFUE
- —
The Triangle Tube Phase III SMART 100 is a discontinued 95-gallon indirect water heater with 25 gallons of boiler water, 36 sq ft of heating surface and a printed first-hour flow of 525 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.
Natural gasPropaneDHW-only (tankless)