CurrentCanadian status unknown
- Input
- 8–80 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom II PHTM2080H is the smallest Phantom II heat-only boiler: 8 to 80 MBH input at 95.0% AFUE with 10:1 modulation, 75 MBH DOE heating capacity and a 65 MBH net AHRI rating, in the shared 16.3 × 17.8 × 29.8 inch cabinet.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 13.6–120 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom II PHTM2120H fires 13.6 to 120 MBH at 95.0% AFUE with 112 MBH DOE heating capacity and a 97 MBH net AHRI rating, keeping the same 16.3 × 17.8 × 29.8 inch cabinet as the 2080H at 112 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 20–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom II PHTM2150H fires 20 to 150 MBH at 95.0% AFUE with 141 MBH DOE heating capacity and a 123 MBH net AHRI rating, stepping to the deeper 20.4-inch cabinet at 132 lb shipping.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 20–180 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom II PHTM2180H is the largest Phantom II heat-only boiler: 20 to 180 MBH input at 95.0% AFUE with 169 MBH DOE heating capacity and a 147 MBH net AHRI rating, in the same 132 lb large cabinet as the 2150H.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 13.6–120 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom II Combi PHTM2136C heats at 13.6 to 120 MBH input and fires 13.6 to 136 MBH for domestic hot water at 95.0% AFUE, drawing up to 3.7/3.4/2.9 GPM at 70/77/90°F rises from the small 112 lb cabinet.
Natural gasPropaneCombi
CurrentCanadian status unknown
- Input
- 20–150 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom II Combi PHTM2200C is the largest Phantom II combi: space heating at 20 to 150 MBH input plus a DHW side firing 20 to 200 MBH, drawing up to 5.2/4.7/4.0 GPM at 70/77/90°F rises, in the 135 lb large cabinet.
Natural gasPropaneCombi
CurrentCanadian status unknown
- Input
- 42–210 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom-X PHNTM210 fires 42 to 210 MBH input at 95.0% AFUE with 5:1 modulation: 194 MBH gross output and a 169 MBH net AHRI rating on the Sage2.x control with outdoor reset, at about 206 lb shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 57–285 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Phantom-X PHNTM285 is the largest Phantom-X: 57 to 285 MBH input at 95.0% AFUE with 262 MBH gross output and a 228 MBH net AHRI rating on the Sage2.x control, connecting on 1-1/4" NPT supply/return at about 256 lb.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83 %
The Crown Aruba 4 AWR038E is the smallest legacy AWR cast-iron boiler: a fixed 38 MBH input for 32 MBH DOE heating capacity and a 28 MBH net AHRI rating at 83.0% AFUE, Category I natural draft with a mandatory vent damper.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.5 %
The Crown Aruba 4 AWR070E fires a fixed 70 MBH for 58 MBH DOE heating capacity and a 50 MBH net AHRI rating at 83.5% AFUE across 3 cast-iron sections — the second size of the legacy Category I AWR line.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.7 %
The Crown Aruba 4 AWR105E fires a fixed 105 MBH for 87 MBH DOE heating capacity and a 76 MBH net AHRI rating at the line's highest 83.7% AFUE across 4 cast-iron sections, with a 5" flue connector.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.6 %
The Crown Aruba 4 AWR140E fires a fixed 140 MBH for 117 MBH DOE heating capacity and a 102 MBH net AHRI rating at 83.6% AFUE across 5 cast-iron sections, stepping to a 6" flue connector.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.5 %
The Crown Aruba 4 AWR175E fires a fixed 175 MBH for 146 MBH DOE heating capacity and a 127 MBH net AHRI rating at 83.5% AFUE across 6 cast-iron sections, with a 7" flue connector.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.4 %
The Crown Aruba 4 AWR210E fires a fixed 210 MBH for 175 MBH DOE heating capacity and a 152 MBH net AHRI rating at 83.4% AFUE across 7 cast-iron sections, with a 7" flue connector and the taller 33-1/2" dimension B.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.4 %
The Crown Aruba 4 AWR245E fires a fixed 245 MBH for 205 MBH DOE heating capacity and a 178 MBH net AHRI rating at 83.4% AFUE across 8 cast-iron sections, with the 8" flue connector and alcove clearance group.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.3 %
The Crown Aruba 4 AWR280E is the largest legacy AWR boiler: a fixed 280 MBH input for 234 MBH DOE heating capacity and a 203 MBH net AHRI rating at 83.3% AFUE across 9 cast-iron sections, with an 8" flue connector.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR038C is the smallest Aruba 6 (two sections; not for installation above 2,000 ft): a fixed 38 MBH input for 32 MBH DOE heating capacity and a 28 MBH net AHRI water rating at 84.0% AFUE, with a 4" flue collar, 1 US gallons of water content and 202 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR070C is a 70 MBH three-section size: a fixed 70 MBH input for 59 MBH DOE heating capacity and a 51 MBH net AHRI water rating at 84.0% AFUE, with a 4" flue collar, 2 US gallons of water content and 254 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR105C is a 105 MBH four-section size: a fixed 105 MBH input for 88 MBH DOE heating capacity and a 77 MBH net AHRI water rating at 84.0% AFUE, with a 5" flue collar, 3 US gallons of water content and 304 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR140C is a 140 MBH five-section size: a fixed 140 MBH input for 117 MBH DOE heating capacity and a 102 MBH net AHRI water rating at 84.0% AFUE, with a 6" flue collar, 4 US gallons of water content and 357 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR175C is a 175 MBH six-section size: a fixed 175 MBH input for 146 MBH DOE heating capacity and a 127 MBH net AHRI water rating at 84.0% AFUE, with a 6" flue collar, 5 US gallons of water content and 405 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR210C is a 210 MBH seven-section size: a fixed 210 MBH input for 176 MBH DOE heating capacity and a 153 MBH net AHRI water rating at 84.0% AFUE, with a 7" flue collar, 6 US gallons of water content and 462 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR245C is a 245 MBH eight-section size: a fixed 245 MBH input for 205 MBH DOE heating capacity and a 178 MBH net AHRI water rating at 84.0% AFUE, with a 7" flue collar, 7 US gallons of water content and 518 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Aruba 6 AWR280C is the largest Aruba 6 (nine sections): a fixed 280 MBH input for 234 MBH DOE heating capacity and a 203 MBH net AHRI water rating at 84.0% AFUE, with a 8" flue collar, 8 US gallons of water content and 564 lb approximate shipping weight.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF070CN is the natural-gas 3-section size of the induced-draft cast-iron water line: a fixed 70 MBH input for 60 MBH heating capacity and a 52 MBH net AHRI rating at 85% AFUE.
Natural gasHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF105CN is the natural-gas 4-section size of the induced-draft cast-iron water line: a fixed 105 MBH input for 90 MBH heating capacity and a 78 MBH net AHRI rating at 85% AFUE.
Natural gasHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF140CN is the natural-gas 5-section size of the induced-draft cast-iron water line: a fixed 140 MBH input for 120 MBH heating capacity and a 104 MBH net AHRI rating at 85% AFUE.
Natural gasHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF175CN is the natural-gas 6-section size of the induced-draft cast-iron water line: a fixed 175 MBH input for 150 MBH heating capacity and a 130 MBH net AHRI rating at 85% AFUE.
Natural gasHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF210CN is the natural-gas 7-section size of the induced-draft cast-iron water line: a fixed 210 MBH input for 179 MBH heating capacity and a 156 MBH net AHRI rating at 85% AFUE.
Natural gasHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Bali 3 BWF245CN is the natural-gas 8-section size of the induced-draft cast-iron water line: a fixed 245 MBH input for 208 MBH heating capacity and a 181 MBH net AHRI rating at 84% AFUE.
Natural gasHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF063CL is the propane 3-section size of the induced-draft cast-iron water line: a fixed 63 MBH input for 54 MBH heating capacity and a 47 MBH net AHRI rating at 85% AFUE.
PropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF094CL is the propane 4-section size of the induced-draft cast-iron water line: a fixed 94.5 MBH input for 81 MBH heating capacity and a 70 MBH net AHRI rating at 85% AFUE.
PropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF126CL is the propane 5-section size of the induced-draft cast-iron water line: a fixed 126 MBH input for 108 MBH heating capacity and a 94 MBH net AHRI rating at 85% AFUE.
PropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF157CL is the propane 6-section size of the induced-draft cast-iron water line: a fixed 157.5 MBH input for 135 MBH heating capacity and a 117 MBH net AHRI rating at 85% AFUE.
PropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 85 %
The Crown Bali 3 BWF189CL is the propane 7-section size of the induced-draft cast-iron water line: a fixed 189 MBH input for 161 MBH heating capacity and a 140 MBH net AHRI rating at 85% AFUE.
PropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Crown Bali 3 BWF220CL is the propane 8-section size of the induced-draft cast-iron water line: a fixed 220.5 MBH input for 187 MBH heating capacity and a 163 MBH net AHRI rating at 84% AFUE.
PropaneHeating-only
CurrentCanadian status unknown
- Input
- 8.5–85 MBH
- Output (max)
- —
- AFUE
- 96 %
The Crown Raptor RPTR085HB fires 8.5 to 85 MBH input at 96% AFUE with 79 MBH DOE heating capacity and a 69 MBH net AHRI rating, on the stainless-steel fire-tube condensing platform.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 11–110 MBH
- Output (max)
- —
- AFUE
- 96 %
The Crown Raptor RPTR110HB fires 11 to 110 MBH input at 96% AFUE with 103 MBH DOE heating capacity and a 90 MBH net AHRI rating, on the stainless-steel fire-tube condensing platform.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 15.5–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Raptor RPTR155HB fires 15.5 to 155 MBH input at 95% AFUE with 145 MBH DOE heating capacity and a 126 MBH net AHRI rating, on the stainless-steel fire-tube condensing platform.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 15.5–155 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Raptor RPTR155CB Combi fires 15.5 to 155 MBH input at 95% AFUE with 145 MBH DOE heating capacity and a 126 MBH net AHRI rating, adding tankless domestic hot water through a thermostatic mixing valve and brazed plate heat exchanger, on the stainless-steel fire-tube condensing platform.
Natural gasPropaneCombi
CurrentCanadian status unknown
- Input
- 20.5–205 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Raptor RPTR205HB fires 20.5 to 205 MBH input at 95% AFUE with 189 MBH DOE heating capacity and a 164 MBH net AHRI rating, on the stainless-steel fire-tube condensing platform.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- 27–270 MBH
- Output (max)
- —
- AFUE
- 95 %
The Crown Raptor RPTR270HB fires 27 to 270 MBH input at 95% AFUE with 252 MBH DOE heating capacity and a 219 MBH net AHRI rating, on the stainless-steel fire-tube condensing platform.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 30–70 MBH
- Output (max)
- —
- AFUE
- —
The Crown Bimini BWC070 is the 70-MBH-class model of the Sola-control BWC generation (suffix EN for natural gas, EL for propane): an aluminum, wall-hung, direct-vent condensing boiler firing 30–70 MBH with 63 MBH DOE heating capacity and a 55 MBH net water rating.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 30–90 MBH
- Output (max)
- —
- AFUE
- —
The Crown Bimini BWC090 is the 90-MBH-class model of the Sola-control BWC generation (suffix EN for natural gas, EL for propane): an aluminum, wall-hung, direct-vent condensing boiler firing 30–90 MBH with 80 MBH DOE heating capacity and a 70 MBH net water rating.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 40–120 MBH
- Output (max)
- —
- AFUE
- —
The Crown Bimini BWC120 is the 120-MBH-class model of the Sola-control BWC generation (suffix EN for natural gas, EL for propane): an aluminum, wall-hung, direct-vent condensing boiler firing 40–120 MBH with 107 MBH DOE heating capacity and a 93 MBH net water rating.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 50–150 MBH
- Output (max)
- —
- AFUE
- —
The Crown Bimini BWC151 is the 150-MBH-class model of the Sola-control BWC generation (suffix EN for natural gas, EL for propane): an aluminum, wall-hung, direct-vent condensing boiler firing 50–150 MBH with 135 MBH DOE heating capacity and a 119 MBH net water rating.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 50–150 MBH
- Output (max)
- —
- AFUE
- —
The Crown Bimini BWC150 is the 150-MBH-class floor model of the MCBA-control BWC generation (LP suffix for propane): an aluminum condensing boiler firing 50–150 MBH with 133 MBH DOE heating capacity and a 117 MBH net water rating over 3 sections, with a 4" vent-collar inlet and 3" exhaust collar.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- 75–225 MBH
- Output (max)
- —
- AFUE
- —
The Crown Bimini BWC225 is the 225-MBH-class floor model of the MCBA-control BWC generation (LP suffix for propane): an aluminum condensing boiler firing 75–225 MBH with 202 MBH DOE heating capacity and a 176 MBH net water rating over 4 sections, with a 4" vent-collar inlet and 4" exhaust collar.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.1 %
The Crown Cayman CWI103 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 103 MBH input over 4 sections with 86 MBH heating capacity and a 75 MBH AHRI net rating at 83.1% AFUE.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.1 %
The Crown Cayman CWI138 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 138 MBH input over 5 sections with 115 MBH heating capacity and a 100 MBH AHRI net rating at 83.1% AFUE.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.2 %
The Crown Cayman CWI172 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 172 MBH input over 6 sections with 144 MBH heating capacity and a 125 MBH AHRI net rating at 83.2% AFUE.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.2 %
The Crown Cayman CWI207 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 207 MBH input over 7 sections with 173 MBH heating capacity and a 150 MBH AHRI net rating at 83.2% AFUE.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.2 %
The Crown Cayman CWI241 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 241 MBH input over 8 sections with 201 MBH heating capacity and a 175 MBH AHRI net rating at 83.2% AFUE.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 83.2 %
The Crown Cayman CWI276 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 276 MBH input over 9 sections with 230 MBH heating capacity and a 200 MBH AHRI net rating at 83.2% AFUE.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- —
The Crown Cayman CWI311 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 310 MBH input over 10 sections with 252 MBH heating capacity and a 219 MBH AHRI net rating at 81.4% thermal efficiency.
Natural gasHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- —
The Crown Cayman CWI346 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 345 MBH input over 11 sections with 281 MBH heating capacity and a 244 MBH AHRI net rating at 81.4% thermal efficiency.
Natural gasHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- —
The Crown Cayman CWI380 is a legacy cast-iron gas water boiler with an integrated tankless domestic coil: 379 MBH input over 12 sections with 309 MBH heating capacity and a 269 MBH AHRI net rating at 81.4% thermal efficiency.
Natural gasHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Crown Bermuda 2 BSI069B is the smallest Bermuda 2 size of the current cast-iron gas steam line: 69 MBH input, 57 MBH DOE heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, over 3 cast-iron sections with 5.1 gallons of boiler water.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Crown Bermuda 2 BSI103B is a 103 MBH mid-small size of the current cast-iron gas steam line: 103 MBH input, 84 MBH DOE heating capacity and a 63 MBH AHRI net steam rating (263 sq ft) at 82% AFUE, over 4 cast-iron sections with 6.5 gallons of boiler water.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Crown Bermuda 2 BSI138B is a 138 MBH mid size of the current cast-iron gas steam line: 138 MBH input, 113 MBH DOE heating capacity and a 85 MBH AHRI net steam rating (354 sq ft) at 82% AFUE, over 5 cast-iron sections with 7.9 gallons of boiler water.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.1 %
The Crown Bermuda 2 BSI172B is a 172 MBH mid-large size of the current cast-iron gas steam line: 172 MBH input, 142 MBH DOE heating capacity and a 107 MBH AHRI net steam rating (446 sq ft) at 82.1% AFUE, over 6 cast-iron sections with 9.3 gallons of boiler water.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.1 %
The Crown Bermuda 2 BSI207B is a 207 MBH large size of the current cast-iron gas steam line: 207 MBH input, 171 MBH DOE heating capacity and a 128 MBH AHRI net steam rating (533 sq ft) at 82.1% AFUE, over 7 cast-iron sections with 10.7 gallons of boiler water.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.2 %
The Crown Bermuda 2 BSI241B is a 241 MBH large size of the current cast-iron gas steam line: 241 MBH input, 199 MBH DOE heating capacity and a 149 MBH AHRI net steam rating (621 sq ft) at 82.2% AFUE, over 8 cast-iron sections with 12.1 gallons of boiler water.
Natural gasPropaneHeating-only
CurrentCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.2 %
The Crown Bermuda 2 BSI276B is the largest Bermuda 2 size of the current cast-iron gas steam line: 276 MBH input, 229 MBH DOE heating capacity and a 172 MBH AHRI net steam rating (717 sq ft) at 82.2% AFUE, over 9 cast-iron sections with 13.5 gallons of boiler water.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Crown Bermuda BSI069 is the smallest legacy Bermuda size of the legacy cast-iron gas steam line: 69 MBH input, 57 MBH heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, over 3 cast-iron sections with 5.1 gallons of boiler water.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Crown Bermuda BSI103 is a 103 MBH mid-small size of the legacy cast-iron gas steam line: 103 MBH input, 85 MBH heating capacity and a 64 MBH AHRI net steam rating (267 sq ft) at 82% AFUE, over 4 cast-iron sections with 6.5 gallons of boiler water.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Crown Bermuda BSI138 is a 138 MBH mid size of the legacy cast-iron gas steam line: 138 MBH input, 113 MBH heating capacity and a 85 MBH AHRI net steam rating (354 sq ft) at 82% AFUE, over 5 cast-iron sections with 7.9 gallons of boiler water.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.1 %
The Crown Bermuda BSI172 is a 172 MBH mid-large size of the legacy cast-iron gas steam line: 172 MBH input, 142 MBH heating capacity and a 107 MBH AHRI net steam rating (446 sq ft) at 82.1% AFUE, over 6 cast-iron sections with 9.3 gallons of boiler water.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.1 %
The Crown Bermuda BSI207 is a 207 MBH large size of the legacy cast-iron gas steam line: 207 MBH input, 171 MBH heating capacity and a 128 MBH AHRI net steam rating (533 sq ft) at 82.1% AFUE, over 7 cast-iron sections with 10.7 gallons of boiler water.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.2 %
The Crown Bermuda BSI241 is a 241 MBH large size (available semi-packaged) of the legacy cast-iron gas steam line: 241 MBH input, 199 MBH heating capacity and a 149 MBH AHRI net steam rating (621 sq ft) at 82.2% AFUE, over 8 cast-iron sections with 12.1 gallons of boiler water.
Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
- Input
- —
- Output (max)
- —
- AFUE
- 82.2 %
The Crown Bermuda BSI276 is the largest legacy Bermuda size (available semi-packaged) of the legacy cast-iron gas steam line: 276 MBH input, 229 MBH heating capacity and a 172 MBH AHRI net steam rating (717 sq ft) at 82.2% AFUE, over 9 cast-iron sections with 13.5 gallons of boiler water.
Natural gasPropaneHeating-only