Bradford White Brute FT boilers (hard/soft lockout codes, I&O Document 1538D)
10
Combustion fault Flame has Extinguished 8 (Eight) Times. Press the Power button to clear the Error Code. If Error happens again: 1. Monitor …
Lockout
11
Ignition fault Ignition has Failed 10 (Ten) Times. Press the Power button to clear the Error Code. If Error happens again: 1. Monitor the ga…
Lockout
16
Water temperature over-heating fault Operating Temperature Sensor detects Water Temperature Greater than 203°F (95°C). Press the Power butto…
Details
27
High CO2 sensor accumulator value. Check for flue gas recirculation. The boiler is bringing flue gases back into the boiler. 1. Blinking dis…
Details
30
System sensor fault. This Error Code will go away when System temperature decreases. If Error happens again: 1. Check System temperature sen…
Details
31
Return sensor fault. This Error Code will go away when Return temperature decreases. If Error happens again: 1. Check Return temperature sen…
Details
32
DHW outlet sensor fault. This Error Code will go away when CH temperature decreases. If Error happens again: 1. Check DHW or CH temperature …
Details
33
OP Water temperature sensor fault. This Error Code will go away when CH temperature decreases. If Error happens again: 1. Check DHW or CH te…
Details
34
L-tt sensor fault. This Error Code will go away when L-tt temperature decreases. If Error happens again: 1. Check L-tt temperature sensor. E…
Details
35
Exhaust sensor fault. This Error Code will go when Exhaust temperature decreases. If Error happens again: 1. Check Exhaust temperature senso…
Details
37
Power frequency fault. Supply frequency is too high to operate. This Error Code will go away when supply frequency returns to normal operati…
Details
38
EPROM fault. Press the Power button to clear the Error Code. If the problem persists. contact technical support. The table classifies it as …
Details
40
Gas leakage fault. IMPORTANT: If you smell gas, STOP! Follow the instructions on page 2 of this manual, and call a qualified service technic…
Details
42
External LWCO/ safety fault. Press the Power button to clear the Error Code. If Error happens again: 1. Ensure the LWCO jumper wire is prope…
Details
43
Burner over- heating fault. Press the Power button to clear the Error Code. If Error happens again: 1. Check boiler overheat switch and ther…
Details
44
Air Pressure Sensor Range (APS) Fault. Press the power button to reset If error happens again: 1. Check the vent pipe for blockages. 2. Chec…
Details
45
Air Pressure Sensor Fault. Check the aps connection. 1. IfAPS is closed and connections are secure, checkAPS connection. 2. If the problem i…
Details
61
Fan fault. This Error Code will go away when the condition is remedied. If Error happens again: 1. Check the connections to the fan. Ensure …
Lockout
70
MCU self diagnostics fault. This Error Code will go away when the condition is remedied. If Error happens again: 1. Turn power OFF and ON at…
Details
72
Flame Signal Fault. This Error Code will go away when the condition is remedied. If Error happens again: 1. Turn power OFF and ON. 2. Check …
Lockout
76
Display to main control communication fault. This Error Code will go away when the condition is remedied. If Error happens again: 1. Check c…
Details
77
Outdoor sensor error. This Error Code will go away when the condition is remedied. If Error happens again: 2. Check outdoor sensor resistanc…
Details
78
Cascade signal fault. This error will go away by connectiong the cascade cable when operating multiple boilers in cascade mode. 1.Checkifall…
Details
80
Internal low water cut-off fault. This Error Code will go away when the condition is remedied. If Error happens again: 1. Ensure all valves …
Details
81
Internal low water cut-off fault. This Error Code will go away when the condition is remedied. If Error happens again: 1. Ensure all valves …
Details
85
Anti-freeze fault (Appliance has detected water temperature below 34°F(1°C). This Error Code will go away when the freezing condition is rem…
Details
94
Exhaust gas temperature fault. This Error Code will go away when the condition is remedied. If Error happens again: 1. Check if DIP switch M…