Burnham · Series 2

Burnham Series 2 208E

The Burnham Series 2 208E is a current cast-iron gas water boiler: 241 MBH input for 202 MBH DOE heating capacity and a 176 MBH AHRI net water rating at 84.0% AFUE, with 8 cast-iron sections, a 7" vent, a 3/4" NPT gas connection and 7 gallons of water content at 502 lb shipping.

CurrentCanadian status unknown

Key figures

Max input
Max CSA output
AFUE
84 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Burnham Series 2 208E in practice

The Series 2 208E is one of the eight current cast-iron gas water boiler sizes in U.S. Boiler Company's Series 2 line. Its submittal row prints 241 MBH input, 202 MBH DOE heating capacity and a 176 MBH AHRI net water rating (1.15 allowance) at 84.0% AFUE, with 8 sections, a 7" vent diameter, a 3/4" NPT gas connection and 7 gallons of water content.

The boiler measures 28 in. wide x 27 in. deep, ships at 502 lb (empty weight 431 lb) and is a chimney-vented atmospheric cast-iron design with a heavy-duty steel base. Input ratings apply from sea level to 2,000 ft; conversion kits are documented for LP combustion (109706-01/-02, 109729-01) and for the 2,001–5,400 ft and 5,401–10,000 ft altitude bands.

Boilers.ca records the printed row for the 208E; no official Canadian-sales statement was found, so canadianStatus stays 'unknown', and gas, combustion and venting work belongs with a licensed contractor against the Series 2e I&O manual.

Best suited to

  • 241-MBH-class residential loads (202 MBH DOE heating capacity)
  • Chimney-vented cast-iron replacements on the long-running Series 2 platform
  • Systems needing 7 gallons of boiler water content in a 8-section casting

Applicability and support

Model number
208E
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Burnham. Units are shown with every value; notes flag conflicting sources or missing figures.

Burnham Series 2 208E specifications
SpecificationValueNote
Input
Input241 MBHInput per the official Series 2 submittal ratings table (sea level to 2,000 ft; conversion kits required above).
Output
DOE heating capacity202 MBHDOE heating capacity per the official submittal.
AHRI net water rating176 MBHAHRI net water rating based on a piping and pickup allowance of 1.15 per the submittal.
Efficiency
Efficiency (AFUE)84 %84.0% AFUE per the submittal ratings table; the product page carries an 84% Efficiency badge.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent diameter7"Vent diameter per the Series 2 dimensions table; chimney-vented atmospheric design with draft hood.
Physical and connections
Cast-iron sections8Number of sections per the Series 2 dimensions table.
Dimensions28 in. wide x 27 in. deepDimensions per the Series 2 submittal dimensions table (section count drives width).
Gas connection3/4" NPTGas connection per the Series 2 dimensions table.
Shipping weight502 lbShipping weight 502 lb (empty weight 431 lb) per the Series 2 weights table.
Water content7 galWater content per the Series 2 weights and volume table.
Operating limits and other
FuelNatural gas or propaneShips for natural gas from sea level to 2,000 ft; LP and altitude conversion kits are documented in the submittal chart.

Frequently asked questions

What are the Series 2 208E's ratings?

241 MBH input, 202 MBH DOE heating capacity and a 176 MBH AHRI net water rating at 84.0% AFUE per the official submittal.

How many sections does the 208E have?

8 cast-iron sections, with a 7" vent and a 3/4" NPT gas connection per the submittal tables.

Does the 208E need a chimney?

Yes — the Series 2 is a chimney-vented atmospheric cast-iron boiler with a draft hood; the submittal lists vent diameters by size.

Questions about the Burnham Series 2 208E?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.