Skip to content
Boilers.caby ROMA Heating & Cooling

HTP · Elite XL Commercial Condensing Boiler

HTP Elite XL ELX-2000FBN

The HTP Elite XL ELX-2000FBN is the 2000 MBH class model of HTP's current commercial condensing line: 200 to 2,000 MBH input, 1940 MBH heating capacity, a 316L stainless steel water-tube heat exchanger and up to 10:1 modulation in a 1750 lb floor-standing cabinet.

CurrentCanadian status unknown

Key figures

Max input
2,000 MBH
Max CSA output
AFUE
Min input
200 MBH
Natural gasHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

HTP Elite XL ELX-2000FBN in practice

The ELX-2000FBN is the 2000 size of HTP's Elite XL commercial condensing boiler — a floor-standing, fully condensing unit on the 928 control with color touchscreen and HTP Link Wi-Fi. The official page table and LP-691 submittal print 200 to 2,000 Btu/hr input, 1940 MBH heating capacity, 16.25 gal of boiler water content and a 1750 lb shipping weight, with a minimum flow rate of 20 GPM at a 20 °F ΔT at low fire.

The boiler uses a 316L stainless steel water-tube heat exchanger stamped for 160 PSI ASME with a gasketless header design, a high-grade stainless-steel premix burner and an air-ratio (pneumatic) gas valve with a 10:1 turndown. It vents Category IV as a sealed-combustion direct-vent or power-vent appliance in PVC, CPVC, polypropylene or stainless steel — the 2000 model uses the 8" adapter — 8" (150 ft) max combined, 15 ft minimum — and connects 2-1/2" flange supply/return with a 2" NPT gas inlet. LP-691 prints the 1500 and 2000 models as natural gas operation only; the gas supply pressure range is natural gas only: 3.5"–10.5" w.c..

The 928 control provides outdoor reset with indirect priority (an outdoor sensor is supplied), 0-10 VDC BMS input, multiple 120-volt pump outputs and cascade wiring for up to eight boilers. HTP backs the heat exchanger with a five-year basic / ten-year extended limited warranty (the page states a 10-year limited warranty with no registration required). The official page carries a live ELX-2000 burner improvement notice: 'ALL ELX-2000 burners with the identified serial numbers are REQUIRED to be replaced as soon as possible' — owners should use the serial-number check on the page. No official statement of Canadian sales was found on htproducts.com, so canadianStatus is 'unknown'; commercial gas work belongs with a licensed contractor against lp-666.

Best suited to

  • Commercial or large residential plants whose heat-loss calculation fits 1940 MBH of heating capacity
  • Natural-gas-only installations at the 1500–2000 MBH scale
  • Plants that can use the 8" adapter vent adapter and cascade up to eight Elite XL boilers

Applicability and support

Model number
ELX-2000FBN
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.

HTP Elite XL ELX-2000FBN specifications
SpecificationValueNote
Input
Input rate, minimum200 MBH200,000 Btu/hr, as printed on the official page table and LP-691.
Input rate, maximum2,000 MBH2,000,000 Btu/hr, as printed on the official page table and LP-691.
Output
Heating capacity1,940 MBHHeating capacity as printed in the LP-691 technical specifications.
Efficiency
Thermal efficiency (page and submittal claim)Up to 97%The official page states 'The Thermal Efficiency rating for the Elite XL is 97% with Ultra Low NOx operation'; the LP-691 submittal prints 'Up to 97% thermal efficiency'. No per-model efficiency column is printed on the model table.
Venting and air
Vent size and maximum combined run8" adapter — 8" (150 ft) max combined, 15 ft minimumMinimum combined vent run 15 ft, as printed in LP-691.
Approved vent materialsPVC, CPVC, polypropylene or stainless steelCategory IV, sealed-combustion direct vent / power vent; LP-690 permits indoor or outdoor installation with the optional kit.
Physical and connections
Shipping weight1,750 lbShipping weight as printed in the LP-691 technical specifications.
Boiler water content16.25 galBoiler water content as printed in the LP-691 technical specifications.
Gas connection2" NPTAs printed in the LP-691 connection table.
Supply / return connection2-1/2" flangeAs printed in the LP-691 connection table.
Dimensions (W x H x D)31.8" W x 60.8" H x 79" DUnit dimensions as printed in the LP-691 dimensions table.
Packaging dimensions (W x H x D)43.25" W x 64.25" H x 86" DAs printed in the LP-691 packaging table.
Gas supply pressureNatural gas only: 3.5"–10.5" w.c.LP-691: 400–1000 models operate on natural or LP gas; 1500–2000 models are natural gas operation only.
Heat exchanger316L stainless steel water tube, 160 PSI ASME stamped, National Board listed, gasketlessLP-691/LP-690 print ASME 160 PSI stamped construction with a gasketless header design and a 4-pass heat exchanger; the heat exchanger is removable from the cabinet.
Water pressureHeat exchanger MAWP 160 psi; ASME 50 psi relief valveLP-691 prints a 160 PSI MAWP and a 50 PSI ASME relief valve; boiler setpoint range 50–190 °F (32–190 °F with outdoor reset curve).
Electrical
Power supply208 V / 3-phase wye / 60 Hz, 15 A per leg
Operating limits and other
Minimum flow rate at 20 °F ΔT at low fire20 GPMAs printed in LP-691; a high-resolution flow switch protects the heat exchanger.
Flow switch activation9 GPMAs printed in LP-691.
TurndownUp to 10:1Page copy and LP-690 specification print a modulation turndown of up to 10:1; LP-691 prints 'Modulating burner with up to 10 to 1 turndown'.
DHW indirect setpoint range70–185 °FAs printed in the LP-691 technical specifications.
Control928 digital operating control with color touchscreen; HTP Link Wi-Fi standardLP-691 prints a 928 control with color touchscreen, embedded Wi-Fi, 0-10 VDC input/outputs, outdoor reset with indirect priority (outdoor sensor supplied) and cascade up to 8 boilers.
Safety devicesFlame rectifier probe, dual water supply temperature sensor/high limit (210 °F), freeze protection, condensate trap with float, dual flue sensor (210 °F), blocked vent pressure switch, integrated UL 353 CSD-1 low-water cut-off, high-resolution flow switchAs printed in LP-691; the 400–1000 models also carry caster wheels with adjustable leveling pads.
WarrantyFive (5) year basic / ten (10) year extended limited warranty on the heat exchangerLP-691 and LP-690 print the 5-year basic / 10-year extended limited warranty; the official page states the boiler 'is backed by a 10 year limited warranty - no registration is required.'

Frequently asked questions

What is the input range of the ELX-2000FBN?

The official table and LP-691 print 200 to 2,000 Btu/hr with 1940 MBH heating capacity.

What fuel does the ELX-2000FBN use?

LP-691 prints the 1500 and 2000 models as 'Natural Gas Operation Only' (3.5"–10.5" w.c. supply pressure).

How much does the ELX-2000FBN weigh and how much water does it hold?

LP-691 prints a 1750 lb shipping weight, 16.25 gal of boiler water content and a minimum flow rate of 20 GPM at a 20 °F ΔT at low fire.

Questions about the HTP Elite XL ELX-2000FBN?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate