Skip to content
Boilers.caby ROMA Heating & Cooling

Laars Heating Systems · Series

Laars Heating Systems Mascot LX (discontinued)

The Mascot LX is Laars' discontinued wall-mounted modulating line in seven boiler sizes from 50 to 220 MBH — MLX 50, 75, 100, 125, 150, 175 and 220 — plus the MLXC combi at 125, 150 and 175 MBH, all rated 95% AFUE. Laars files the 1285 I&O manual and warranty under Discontinued Documents.

discontinuedhistoricalNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95% AFUE
Fuel
Natural gas or propane; the I&O manual's nomenclature uses N for natural gas and P for propane and notes a 4% per 1,000 ft derate above 2,000 ft.
Venting
Unknown
Models documented
7
Warranty
Not verified

95% AFUE printed for every MLX size in the Mascot LX I&O manual's sizing table (Document 1285).

About the Mascot LX (discontinued)

The Mascot LX manual covers the MLXH wall-mounted modulating boiler in 50, 75, 100, 125, 150, 175 and 220 MBH and the MLXC combination boiler in 125, 150 and 175 MBH. The sizing table prints each size's input and output — 50,000/47,500 BTU/h up to 220,000/209,000 BTU/h — at 95% AFUE, with 1/2 in NPT gas connections throughout, 3/4 in NPT water connections on the 50 through 125 sizes stepping to 1 in NPT on the 150 through 220 sizes, and combi domestic-water outputs of 3.1, 3.7 and 4.3 gpm at a 75°F rise on the MLXC 125, 150 and 175.

The manual's nomenclature decodes the rating plate: M LX for the series, H or C for hydronic versus combination, W for wall-hung, the three-digit size, N or P for fuel, A for the altitude band, a revision digit, an options code (X standard or L low-water cut-off) and a pump option (N with pump). Piping is printed by size group: 50 through 125 use 3/4 in PVC condensate, 3/4 in copper hydronic return, 1/2 in NPT DHW inlet and 3/4 in NPT supply, while 150 through 220 use 3/4 in PVC condensate, 1 in NPT return and supply, 1/2 in NPT DHW and 3/4 in copper second return and supply.

Laars no longer links a Mascot LX page from its current residential navigation and the product URL returns 404; the Document Library files Document 1285, its French version and the Mascot LX parts list and warranty sheet under Discontinued Documents. The manual's shipping weights run from 88 lb (MLX 50) to 161 lb (MLX 220), with the combis at 133, 148 and 163 lb for the 125, 150 and 175.

Highlights

  • Seven boiler sizes: MLX 50, 75, 100, 125, 150, 175 and 220 MBH
  • Three combis: MLXC 125, 150 and 175 MBH at 3.1 / 3.7 / 4.3 gpm (75°F rise)
  • 95% AFUE on every size; inputs 50,000 to 220,000 BTU/h
  • Water connections 3/4 in NPT up to 125 and 1 in NPT from 150
  • Shipping weights 88–161 lb boiler; 133–163 lb combi
  • Document 1285 I&O, parts list and warranty filed under Discontinued Documents

Models

Mascot LX (discontinued) models

One canonical page per model with input, output and efficiency kept separate.

Laars Heating Systems

Laars Mascot LX MLX 50

DiscontinuedHistorically in Canada
Input
Output (max)
47,500 BTU/h
AFUE
95 %

The Laars Mascot LX MLX 50 is a discontinued wall-mounted modulating boiler rated 50,000 BTU/h input and 47,500 BTU/h output at 95% AFUE, with 3/4" NPT water connections and a 88 lb shipping weight.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mascot LX MLX 75

DiscontinuedHistorically in Canada
Input
Output (max)
71,250 BTU/h
AFUE
95 %

The Laars Mascot LX MLX 75 is a discontinued wall-mounted modulating boiler rated 75,000 BTU/h input and 71,250 BTU/h output at 95% AFUE, with 3/4" NPT water connections and a 97 lb shipping weight.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mascot LX MLX 100

DiscontinuedHistorically in Canada
Input
Output (max)
95,000 BTU/h
AFUE
95 %

The Laars Mascot LX MLX 100 is a discontinued wall-mounted modulating boiler rated 100,000 BTU/h input and 95,000 BTU/h output at 95% AFUE, with 3/4" NPT water connections and a 112 lb shipping weight.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mascot LX MLX 125

DiscontinuedHistorically in Canada
Input
Output (max)
118,750 BTU/h
AFUE
95 %

The Laars Mascot LX MLX 125 is a discontinued wall-mounted modulating boiler rated 125,000 BTU/h input and 118,750 BTU/h output at 95% AFUE, with 3/4" NPT water connections and a 126 lb shipping weight. An MLXC combi version of this size is rated 3.1 gpm at a 75°F rise.

Natural gasPropaneCombi

Laars Heating Systems

Laars Mascot LX MLX 150

DiscontinuedHistorically in Canada
Input
Output (max)
142,500 BTU/h
AFUE
95 %

The Laars Mascot LX MLX 150 is a discontinued wall-mounted modulating boiler rated 150,000 BTU/h input and 142,500 BTU/h output at 95% AFUE, with 1" NPT water connections and a 140 lb shipping weight. An MLXC combi version of this size is rated 3.7 gpm at a 75°F rise.

Natural gasPropaneCombi

Laars Heating Systems

Laars Mascot LX MLX 175

DiscontinuedHistorically in Canada
Input
Output (max)
166,250 BTU/h
AFUE
95 %

The Laars Mascot LX MLX 175 is a discontinued wall-mounted modulating boiler rated 175,000 BTU/h input and 166,250 BTU/h output at 95% AFUE, with 1" NPT water connections and a 153 lb shipping weight. An MLXC combi version of this size is rated 4.3 gpm at a 75°F rise.

Natural gasPropaneCombi

Laars Heating Systems

Laars Mascot LX MLX 220

DiscontinuedHistorically in Canada
Input
Output (max)
209,000 BTU/h
AFUE
95 %

The Laars Mascot LX MLX 220 is a discontinued wall-mounted modulating boiler rated 220,000 BTU/h input and 209,000 BTU/h output at 95% AFUE, with 1" NPT water connections and a 161 lb shipping weight.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Laars Mascot LX MLX 50 and Laars Mascot LX MLX 75 and Laars Mascot LX MLX 100 and Laars Mascot LX MLX 125 and Laars Mascot LX MLX 150 and Laars Mascot LX MLX 175 and Laars Mascot LX MLX 220
SpecificationLaars Mascot LX MLX 50Laars Mascot LX MLX 75Laars Mascot LX MLX 100Laars Mascot LX MLX 125Laars Mascot LX MLX 150Laars Mascot LX MLX 175Laars Mascot LX MLX 220
input-min
Input50,000 BTU/h75,000 BTU/h100,000 BTU/h125,000 BTU/h150,000 BTU/h175,000 BTU/h220,000 BTU/h
Output47,500 BTU/h71,250 BTU/h95,000 BTU/h118,750 BTU/h142,500 BTU/h166,250 BTU/h209,000 BTU/h
Efficiency (AFUE)95 %95 %95 %95 %95 %95 %95 %
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Laars Mascot LX MLX 50 vs MLX 75

Read the full comparison: Laars Mascot LX MLX 75 vs MLX 100

Read the full comparison: Laars Mascot LX MLX 100 vs MLX 125

Read the full comparison: Laars Mascot LX MLX 125 vs MLX 150

Error codes and alerts

Mascot LX (discontinued) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Services for Laars Heating Systems boilers

Frequently asked questions

Which sizes did the Mascot LX cover?

The MLXH boiler came in 50, 75, 100, 125, 150, 175 and 220 MBH and the MLXC combi in 125, 150 and 175 MBH, per the sizing table in I&O Document 1285.

Is the Mascot LX still available?

Laars' Mascot LX product URL now returns 404 and the Document Library files the 1285 I&O, parts list and warranty under Discontinued Documents, so the line is discontinued; the manuals remain available for owners and technicians.

What efficiency is the Mascot LX rated at?

Every MLX size in the Document 1285 sizing table is printed at 95% AFUE, with natural gas or propane fuel and a 4% per 1,000 ft derate above 2,000 ft.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate