Laars Heating Systems Mini-Therm JVS (discontinued)

The Mini-Therm II JVS is Laars' discontinued non-condensing residential gas-fired hydronic boiler with electronic intermittent ignition (I.I.D.), built in sizes 50, 75, 100, 125, 160 and 225 MBTU/h. Laars lists the JVS/JVT installation manual on its discontinued-documents index.

discontinuedhistoricalNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
Unknown
Fuel
Natural gas or propane; the dimensional table's gas connection is 1/2 in NPT, with 3/4 in on the 225 natural-gas size and 1/2 in on propane.
Venting
Natural draft with a built-in draft diverter and an automatic vent damper; vent diameter by size is 4 in (50), 5 in (75/100), 6 in (125/160) and 7 in (225) per Document 1025Y.
Models documented
6
Warranty
Not verified

About the Mini-Therm JVS (discontinued)

The Mini-Therm II JVS is one of the two ignition configurations of Laars' Model JV copper-tube hydronic boiler line: the JVS uses an electronic intermittent ignition device (I.I.D.), while the JVT uses a thermocouple with a continuous burning pilot. The 1025Y installation manual covers both at sizes 50-225, and the matching parts list prints the twelve model columns JVS-50, JVT-50, JVS-75, JVT-75, JVS-100, JVT-100, JVS-125, JVT-125, JVS-160, JVT-160, JVS-225 and JVT-225.

The dimensional table gives six cabinet sizes in inches — the 50 at 13-3/8 by 27-3/4 with a 4 in vent, stepping up to the 225 at 25-5/8 by 31-1/2 with a 7 in vent — with 1-1/4 in water connections on every size and 1/2 in gas connections except the 3/4 in natural-gas connection on the 225. The boilers are natural-draft with a built-in draft diverter, an automatic vent damper (standard on U.S. and Canadian models; a metal plug is used on the JVS damper plate, and the JVT damper plate hole is never blocked) and an optional side-wall power venter.

The manual prints no input, output or AFUE rating table: the size number is the input in MBTU/h, and the temperature-rise and flow tables in Section 8 are based on the "Normal Input Rate from the rating plate". Laars' discontinued-documents index lists the Mini-Therm II JVS/JVT installation manual and parts list, and the Document Library files them under Discontinued Documents. The Canadian warranty sheet (Document 8023) covers residential gas boilers other than the Mascots and NeoTherm.

Highlights

  • Sizes 50, 75, 100, 125, 160 and 225 MBTU/h; models JVS-50 through JVS-225
  • Electronic intermittent ignition (I.I.D.) versus the JVT's standing pilot
  • Natural draft with built-in draft diverter and automatic vent damper
  • Vent diameter 4 in (50) to 7 in (225); 1-1/4 in water connections
  • 1/2 in gas connection, 3/4 in natural gas on the 225
  • Laars discontinued-documents index: Mini-Therm II JVS, JVT manual and parts list

Models

Mini-Therm JVS (discontinued) models

One canonical page per model with input, output and efficiency kept separate.

Laars Heating Systems

Laars Mini-Therm II JVS-50

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Laars Mini-Therm II JVS-50 is a discontinued 50 MBTU/h non-condensing residential hydronic boiler with electronic intermittent ignition (I.I.D.), 1-1/4 in water connections and a 4 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVS-75

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Laars Mini-Therm II JVS-75 is a discontinued 75 MBTU/h non-condensing residential hydronic boiler with electronic intermittent ignition (I.I.D.), 1-1/4 in water connections and a 5 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVS-100

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Laars Mini-Therm II JVS-100 is a discontinued 100 MBTU/h non-condensing residential hydronic boiler with electronic intermittent ignition (I.I.D.), 1-1/4 in water connections and a 5 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVS-125

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Laars Mini-Therm II JVS-125 is a discontinued 125 MBTU/h non-condensing residential hydronic boiler with electronic intermittent ignition (I.I.D.), 1-1/4 in water connections and a 6 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVS-160

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Laars Mini-Therm II JVS-160 is a discontinued 160 MBTU/h non-condensing residential hydronic boiler with electronic intermittent ignition (I.I.D.), 1-1/4 in water connections and a 6 in vent.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Mini-Therm II JVS-225

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Laars Mini-Therm II JVS-225 is a discontinued 225 MBTU/h non-condensing residential hydronic boiler with electronic intermittent ignition (I.I.D.), 1-1/4 in water connections and a 7 in vent.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Laars Mini-Therm II JVS-50 and Laars Mini-Therm II JVS-75 and Laars Mini-Therm II JVS-100 and Laars Mini-Therm II JVS-125 and Laars Mini-Therm II JVS-160 and Laars Mini-Therm II JVS-225
SpecificationLaars Mini-Therm II JVS-50Laars Mini-Therm II JVS-75Laars Mini-Therm II JVS-100Laars Mini-Therm II JVS-125Laars Mini-Therm II JVS-160Laars Mini-Therm II JVS-225
input-min
Size / input50 MBTU/h75 MBTU/h100 MBTU/h125 MBTU/h160 MBTU/h225 MBTU/h
output-max
afue
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Laars Mini-Therm II JVS-50 vs JVS-75

Read the full comparison: Laars Mini-Therm II JVS-75 vs JVS-100

Read the full comparison: Laars Mini-Therm II JVS-100 vs JVS-125

Read the full comparison: Laars Mini-Therm II JVS-125 vs JVS-160

Error codes and alerts

Mini-Therm JVS (discontinued) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Services for Laars Heating Systems boilers

Frequently asked questions

What is the difference between the Mini-Therm JVS and JVT?

The JVS uses an electronic intermittent ignition device (I.I.D.) while the JVT uses a thermocouple with a continuous burning pilot, per the introduction of Document 1025Y. Both are otherwise the same Model JV copper-tube hydronic boiler.

What sizes did the Mini-Therm JVS come in?

The manual covers sizes 50-225, and the parts list prints the JVS model columns at 50, 75, 100, 125, 160 and 225 MBTU/h.

Is the Mini-Therm JVS discontinued?

Yes. Laars' discontinued-documents index lists the Mini-Therm II JVS/JVT install and operating manual and parts list, and the Document Library files them under Discontinued Documents.