Lennox GCWB95 110 — Safety Thermostat Tripped Due to Over Temperature
110
Safety thermostat tripped due to over temperature. The safety thermostat tripped due to over temperature, with a probable blocked pump or air in the heating circuit; press the RESET (R) button for at least 2 seconds and call an authorized service technician if the fault persists. The table classifies it as Error.
Applies to
This venting or air-supply fault code is displayed by the GCWB95 control (numeric error display with RESET) on GCWB95 models (GCWB95W-150, GCWB95W-205 wall hung combi and GCWB95F-150 floor mount combi), as documented in Lennox GCWB95 User's Information Manual, PN 240012894 Rev. A [04/15/2020], Section 3.6 error messages (models GCWB95W-150, GCWB95W-205 wall hung combi and GCWB95F-150 floor mount combi) (240012894 Rev. A). Codes can differ between controller generations, so always check the manual that matches your unit.
Controller: GCWB95 control (numeric error display with RESET). Source manual: 240012894 Rev. A (2020-04-15).
Why a code is not a diagnosis
A venting or air-supply code points at the combustion-air path: a blocked terminal, a restricted flue, a failed fan, or a condensate restriction. It does not say which, and running an appliance with a blocked flue is unsafe.
Safe things to observe
- If a carbon-monoxide alarm sounds anywhere in the building, leave immediately and call 911 from outside.
- From a safe distance, check that the vent terminal and combustion-air inlet are not blocked.
- Do not run the appliance while a blockage is suspected.
Do not
- Do not put anything into the vent or air-intake openings.
- Do not remove or modify vent pipe.
How professional service helps
- A technician inspects the full vent and combustion-air path, clears blockages and checks the fan.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Lennox GCWB95 User's Information Manual, PN 240012894 Rev. A [04/15/2020], Section 3.6 error messages (models GCWB95W-150, GCWB95W-205 wall hung combi and GCWB95F-150 floor mount combi) · 240012894 Rev. A · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.