Navien · NCB (first generation)

Navien NCB-180

The Navien NCB-180 is a first-generation wall-hung condensing combi from the discontinued NCB series: 14 to 80 MBH of heating input with 74 MBH heating capacity, 93.5% AFUE and DHW input to 150,000 BTU/h.

DiscontinuedHistorically in Canada

Key figures

Max input
80 MBH
Max CSA output
AFUE
93.5 %
Min input
14 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Navien NCB-180 in practice

The NCB-180 is one of the three original NCB combi models Navien lists under Discontinued Products on both navieninc.ca and navieninc.com. Per the NCB Installation and Operation Manual, it fires 14 to 80 MBH for space heating with a 74 MBH heating capacity and a 64 MBH net AHRI water rating, at 93.5% AFUE.

On the domestic hot water side the NCB-180 fires 14,000 to 150,000 BTU/h and delivers 3.4 GPM at a 77°F (43°C) temperature rise, with a 0.5 GPM minimum flow. It is a true combi — DHW is produced inside the unit through its stainless steel domestic-water heat exchanger — in a 74 lb cabinet measuring 17 × 28 × 12 in with 1" NPT heating connections and 3/4" NPT DHW and gas connections.

Venting is 2" or 3" PVC, CPVC or polypropylene (or special gas vent Type BH), hydronic pressure is rated 12 – 30 psi and the DHW side 15–150 psi. The NCB installation manual states installation up to 10,100 ft for natural gas and 4,500 ft for propane. Owners should match parts and error codes to the NCB generation's own service manual, because Navien's later NCB-E and NCB-H tables changed code meanings between generations.

Best suited to

  • Owners of an existing first-generation NCB looking up its printed ratings and manuals
  • Understanding the input, capacity and DHW range of Navien's original combi line
  • Matching a replacement decision to the documented NCB generation, not a later model

Applicability and support

Model number
NCB-180
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Navien. Units are shown with every value; notes flag conflicting sources or missing figures.

Navien NCB-180 specifications
SpecificationValueNote
Input
Heating input, minimum14 MBHPer the NCB Installation and Operation Manual.
Heating input, maximum80 MBHPer the NCB Installation and Operation Manual.
Output
Heating capacity74 MBHDOE test basis, per the NCB Installation and Operation Manual.
Net AHRI water rating64 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)93.5 %AFUE per the NCB Installation and Operation Manual.
Domestic hot water
DHW input, minimum14 MBH14,000 BTU/h.
DHW input, maximum150 MBH150,000 BTU/h.
DHW flow rate at 77°F (43°C) rise3.4 GPMPer the NCB Installation and Operation Manual; minimum DHW flow 0.5 GPM.
DHW connections3/4" NPTDHW inlet and outlet, 3/4" NPT.
Venting and air
Venting2" or 3" PVC, CPVC, polypropylene; 2" or 3" special gas vent Type BH (Class III A/B/C)Forced-draft direct vent per the official specifications.
Physical and connections
Weight74 lbAs printed in the official document.
Width17 in
Height28 in
Depth12 in
Heating connections1" NPTSupply and return.
Gas connection3/4" NPT
Operating limits and other
FuelNatural gas or propaneRatings are the same for natural gas models converted to propane use; field conversion is licensed gas work.
Hydronic water pressure12 – 30 psiDHW side rated 15–150 psi.

Frequently asked questions

What are the ratings of the Navien NCB-180?

The NCB manual prints 14–80 MBH heating input, 74 MBH heating capacity, a 64 MBH net AHRI water rating and 93.5% AFUE, with DHW input of 14,000–150,000 BTU/h and 3.4 GPM at a 77°F rise.

Is the Navien NCB-180 still sold?

No. Navien lists the original NCB series (NCB-180, NCB-210, NCB-240) under Discontinued Products on both navieninc.ca and navieninc.com; the current Canadian combis are the NCB-H and NFC-H series.

Where can I get the NCB-180 manual?

Navien still hosts the NCB Installation and Operation Manual and NCB Service Manual on navieninc.com, linked from the official NCB-180 product page; the manual is the reference for this model's ratings and error codes.

Questions about the Navien NCB-180?