Skip to content
Boilers.caby ROMA Heating & Cooling

Nebraska Boiler · Series

Nebraska Boiler Nebraska D-Type Watertube

The Nebraska D-Type is Cleaver-Brooks' industrial watertube boiler line — up to 1,050°F superheated steam in the lower-maintenance D configuration, with steam flows from 10,000 to 500,000 lb/hr, design pressures to 1,800 psig and less than 5 ppm NOx availability.

Current seriesunknownNatural gasPropanecommercial

Series facts

Type
non-condensing
Efficiency
Unknown
Fuel
Cleaver-Brooks prints Natural Gas, #2 and #6 oil, refinery fuels, alternative fuels and combination firing; the page notes IWT boilers can fire renewable natural gas, biogas and hydrogen.
Venting
Unknown
Models documented
0
Warranty
Not verified

About the Nebraska D-Type Watertube

Cleaver-Brooks' official D-Type page states: 'The Cleaver-Brooks Nebraska D-type industrial watertube boiler provides up to 1,050°F superheated steam in the lower-maintenance D configuration.' The headline block prints: 'Steam, temperatures to 1,050°F / 10,000 to 500,000 lb/hr / Natural Gas, #2 and #6 oil, refinery fuels, alternative fuels, combination / Design pressure up to 1,800 psig / Available to less than 5ppm NOx, Ultra-Low CO'.

The construction section documents a welded-membrane wall furnace with 100% water-cooled, refractory-free walls (front, rear and burner throat when integrated with the Natcom burner), convective and interstage superheaters, large water-cooled gas-tight furnace areas, radiant superheater designs, SCR and CO catalyst accommodation, and single- or dual-stage integral superheater systems with optional temperature control over turndown.

Applications printed on the page include process steam, industrial process, building heat, hospital and healthcare, power and utilities, refineries and petrochemical, pharmaceutical, pulp and paper, schools, and food and beverage. The page also notes the boilers can fire renewable natural gas, biogas and hydrogen, and achieve <2 ppm NOx with an ultra-low NOx burner and SCR equipment, with options to increase efficiency by 5% on average. No official Canadian-sales statement was found.

Highlights

  • Industrial D-type watertube boiler; superheated steam to 1,050°F
  • Steam flows 10,000 – 500,000 lb/hr; design pressure to 1,800 psig
  • Natural gas, propane, digester gas, #2–#6 oil, refinery and alternative fuels
  • Available to less than 5 ppm NOx; <2 ppm NOx with SCR per the page
  • 100% membrane water-cooled, refractory-free furnace walls
  • Shop or field assembled; natural circulation

Models

Nebraska D-Type Watertube models

One canonical page per model with input, output and efficiency kept separate.

Error codes and alerts

Nebraska D-Type Watertube alerts

No alerts documented for this series yet.

Manuals

Official documents

    Where ROMA provides on-site service

    On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

    See all service areas

    Frequently asked questions

    What sizes does the Nebraska D-Type cover?

    Cleaver-Brooks prints steam flows from 10,000 to 500,000 lb/hr with design pressures up to 1,800 psig and steam temperatures to 1,050°F.

    Can the Nebraska D-Type burn alternative fuels?

    Yes — the page lists natural gas, propane, digester gas, #2–#6 oil, refinery fuels and alternative fuels, and notes the boilers can fire renewable natural gas, biogas and hydrogen.

    Talk to a boiler technician

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate