Peerless Series MI MI-03
The Peerless Series MI MI-03 is the smallest Series MI size of the legacy cast-iron gas water line: 70 MBH fixed input for 58 MBH heating capacity and a 50 MBH net water rating at 82.2% AFUE, with 4.72 US gallons of boiler water content, on the natural-draft chimney platform.
Key figures
- Max input
- —
- Max CSA output
- —
- AFUE
- 82.2 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Peerless Series MI MI-03 in practice
The Series MI MI-03 is a legacy fixed-input cast-iron gas hot water boiler rated at 70 MBH input with 58 MBH heating capacity and a 50 MBH net water rating (piping and pickup allowance 1.15) at 82.2% AFUE per the ratings table on the official product page. Boiler water content is 4.72 US gallons.
The Series MI is fully packaged for conventional chimney applications with a front-facing integral draft diverter, a low-profile design for tight spaces with low ceilings, spark-pilot ignition and a non-prorated lifetime warranty on the heat exchanger per the official product page. The line is grouped under 'Out of Circulation' on the official site.
Boilers.ca documents this size at model level; no official Canadian-sales statement was found, so canadianStatus stays 'unknown'. Installation, gas, combustion and venting work belongs with a licensed contractor against I&O manual MI8038 R19 (10/19).
Best suited to
- Owners documenting an installed Series MI against the official ratings table (70 MBH input)
- Service planning for cast-iron natural-draft boilers with a spark pilot
- Replacement research in the legacy Peerless cast-iron size class
Applicability and support
- Model number
- MI-03
- Canadian availability
- unknown
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Peerless Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input | 70 MBH | Fixed input per the in-page ratings table on the official product page. |
| Output | ||
| Heating capacity | 58 MBH | Heating capacity per the in-page ratings table on the official product page. |
| Net water rating | 50 MBH | Net water rating based on a piping and pickup allowance of 1.15 per the in-page ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 82.2 % | AFUE per the in-page ratings table; ratings are based on U.S. Government tests. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Venting | Natural draft into a conventional chimney | Fully packaged for conventional chimney applications with a front-facing integral draft diverter and a low-profile design (official product page). |
| Physical and connections | ||
| Boiler water content | 4.72 gal | Boiler water content 4.72 US gallons per the in-page ratings table. |
| Operating limits and other | ||
| Fuel | Natural gas or LP gas | Gas-Fired (Natural or LP) per the official product page. |
| Ignition and controls | Spark pilot ignition | Spark-pilot ignition per the official product page product details. |
Manuals
- Series MI & MIHII Installation, Operation & Maintenance Manual (MI8038 R19, 10/19)MI8038 R19 · 2019-10
- Series MI85, MIHII & MI User's Information Manual (MI8082 R6, 10/19)MI8082 R6 · 2019-10
Alerts documented for this model
None documented yet.
Frequently asked questions
What are the MI-03's ratings?
70 MBH fixed input, 58 MBH heating capacity and a 50 MBH net water rating at 82.2% AFUE per the product page ratings table.
Does the MI-03 need a chimney?
Yes — the Series MI is a natural-draft boiler for conventional chimney applications, with a front-facing integral draft diverter and no direct-vent option.
Is the MI-03 still sold?
No — the official site groups the Series MI under 'Out of Circulation' (verified September 9, 2026); the record documents the installed equipment and its I&O manual.
Questions about the Peerless Series MI MI-03?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
Sources and verification
- Peerless Boilers — Series MI product page (ratings and dimensions tables) · accessed September 9, 2026
- Series MI & MIHII Installation, Operation & Maintenance Manual, MI8038 R19 (10/19) (PDF) · MI8038 R19 · accessed September 9, 2026
- Series MI85, MIHII & MI User's Information Manual, MI8082 R6 (10/19) (PDF) · MI8082 R6 · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.