Skip to content
Boilers.caby ROMA Heating & Cooling

Peerless Boilers · Series

Peerless Boilers Series MIHII

The Series MIHII is Peerless' legacy mid-efficiency residential cast-iron gas water boiler — four sizes MIHII-03 through MIHII-06 from 65 to 162.5 MBH input at 84.0–84.1% AFUE, with a low-water cutoff, natural-draft integral draft diverter and spark-pilot ignition. The official site groups the line under 'Out of Circulation'.

discontinuedunknownNatural gasresidential

Series facts

Type
non-condensing
Efficiency
84.1% AFUE
Fuel
Gas-Fired (Natural) per the official product page — the MIHII is listed for natural gas only, unlike the natural-or-LP Series MI.
Venting
Natural draft into a conventional chimney: the product page describes an integral draft diverter and low-profile design for installation in tight spaces and areas with low ceilings.
Models documented
4
Warranty
Not verified

The in-page ratings table prints 84.1% AFUE on the MIHII-03 and MIHII-04 and 84.0% on the MIHII-05 and MIHII-06; the page copy headlines 'an efficiency of 84%'.

About the Series MIHII

The Series MIHII is Peerless' legacy residential cast-iron hot water boiler, published on the official site under the 'Out of Circulation – Gas Boilers' section. The product page describes an integral draft diverter providing a low-profile design for tight spaces and low ceilings, an efficiency of 84%, and a boiler 'designed specifically for markets where utility companies offer rebates for mid-efficiency heating products'. The page positions the MIHII as 'an adaptation of the high quality Series MI boiler with the same features', equipped with a low-water cutoff for safe operation.

The in-page ratings table covers four fixed-input sizes — MIHII-03 (65 MBH input, 55 MBH heating capacity, 48 MBH net water rating, 84.1% AFUE), MIHII-04 (97.5/82/71, 84.1%), MIHII-05 (130/110/96, 84.0%) and MIHII-06 (162.5/137/119, 84.0%) — with net water ratings based on a piping and pickup allowance of 1.15 and boiler water content of 4.72–8.56 US gallons. The dimensions table matches the MI-03 through MI-06 jacket rows: 26-5/8" depth, 12-1/2"–22-5/8" widths, 31-3/8" height and 5" or 6" vent diameters.

The official site groups the Series MIHII under 'Out of Circulation', so Boilers.ca records productStatus 'discontinued' and documents all four sizes at model level from the product page and the shared MI8038 R19 I&O manual. No official Canadian-sales statement was found — research reviewed US-site data only — so canadianStatus stays 'unknown', and gas, combustion and venting work belongs with a licensed contractor.

Highlights

  • Legacy mid-efficiency Peerless cast-iron gas water line: MIHII-03 to MIHII-06 (65–162.5 MBH input)
  • In-page table: 55–137 MBH heating capacity, 48–119 MBH net water ratings, 84.0–84.1% AFUE
  • Low-water cutoff for safe operation; natural-draft integral draft diverter
  • Natural gas only per the product page; spark-pilot ignition
  • Official site groups the line under 'Out of Circulation' — recorded as discontinued
  • Model-level pages published on Boilers.ca; I&O manual MI8038 R19 (10/19) linked here

Models

Series MIHII models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
84.1 %

The Peerless Series MIHII MIHII-03 is the smallest Series MIHII size of the legacy mid-efficiency cast-iron gas water line: 65 MBH fixed input for 55 MBH heating capacity and a 48 MBH net water rating at 84.1% AFUE, with 4.72 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only
DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
84.1 %

The Peerless Series MIHII MIHII-04 is a 97.5 MBH mid-small size of the legacy mid-efficiency cast-iron gas water line: 97.5 MBH fixed input for 82 MBH heating capacity and a 71 MBH net water rating at 84.1% AFUE, with 6 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only
DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
84 %

The Peerless Series MIHII MIHII-05 is a 130 MBH mid size of the legacy mid-efficiency cast-iron gas water line: 130 MBH fixed input for 110 MBH heating capacity and a 96 MBH net water rating at 84% AFUE, with 7.28 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only
DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
84 %

The Peerless Series MIHII MIHII-06 is the largest Series MIHII size of the legacy mid-efficiency cast-iron gas water line: 162.5 MBH fixed input for 137 MBH heating capacity and a 119 MBH net water rating at 84% AFUE, with 8.56 US gallons of boiler water content, a low-water cutoff and natural-draft venting.

Natural gasHeating-only

Compare models in this series

Comparison of Peerless Series MIHII MIHII-03 and Peerless Series MIHII MIHII-04 and Peerless Series MIHII MIHII-05 and Peerless Series MIHII MIHII-06
SpecificationPeerless Series MIHII MIHII-03Peerless Series MIHII MIHII-04Peerless Series MIHII MIHII-05Peerless Series MIHII MIHII-06
input-min
input-max
output-max
Efficiency (AFUE)84.1 %84.1 %84 %84 %
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Peerless Series MIHII MIHII-03 vs MIHII-04

Read the full comparison: Peerless Series MIHII MIHII-04 vs MIHII-05

Read the full comparison: Peerless Series MIHII MIHII-05 vs MIHII-06

Read the full comparison: Peerless Series MIHII MIHII-03 vs MIHII-05

Error codes and alerts

Series MIHII alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Peerless Series MIHII still sold?

No — the official site groups the Series MIHII under 'Out of Circulation' (verified September 9, 2026), so Boilers.ca records productStatus 'discontinued'. The product page and I&O manual remain published for owners of installed units.

What sizes did the Series MIHII come in?

Four fixed-input sizes: MIHII-03 through MIHII-06 at 65, 97.5, 130 and 162.5 MBH input, with 55–137 MBH heating capacities, 48–119 MBH net water ratings and 84.0–84.1% AFUE per the in-page ratings table.

Can the MIHII run on propane?

No — the official product page lists the MIHII as Gas-Fired (Natural) only; the natural-or-LP option belongs to the sibling Series MI.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate