Skip to content
Boilers.caby ROMA Heating & Cooling

Peerless Boilers · Series

Peerless Boilers Series PBC (Peerless Combi)

The Series PBC ('Peerless Combi') is Peerless' current gas-fired condensing combination boiler: wall-hung models PBC-34, PBC-40 and PBC-52 deliver space heating (80–120 MBH maximum CH input) plus on-demand domestic hot water at up to 5.2 GPM, rated 95.1–95.3% AFUE with up to 10:1 turndown and a stainless steel heat exchanger.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95.3% AFUE
Fuel
Natural or LP gas: the product page and cut sheet list every PBC model for natural or LP gas.
Venting
Direct vent, sealed combustion: 2" or 3" piping in PVC, CPVC, polypropylene or AL29-4C stainless (product page and cut sheet); a positive-pressure vent system per the I&O manual (PBC8013-R5).
Models documented
3
Warranty
Not verified

95.1–95.3% AFUE printed per model (PBC-34 95.1%, PBC-40 95.2%, PBC-52 95.3%) in the cut sheet and I&O manual Table 12.2; ENERGY STAR certified per the product page.

About the Series PBC (Peerless Combi)

The Series PBC is Peerless' current combination boiler — a 95%-class condensing heating boiler that also produces domestic hot water — listed on the official site as 'Peerless Combi' under Residential Boilers – Gas Boilers. The product page describes an ENERGY STAR certified, direct-vent boiler using 2" or 3" piping in PVC, CPVC, Polypro or AL29-4C stainless, an isothermic and stainless steel heat exchanger, an easy-to-follow control menu for set-up and service, 10:1 turndown, and a one-year parts-and-labour warranty (upon product registration) plus a 12-year limited heat exchanger warranty for residential use.

Three models cover the range: PBC-34 (15.5–80 MBH CH input, 15.5–130 MBH DHW input, 3.4 GPM DHW at a 70°F rise, 95.1% AFUE, 8.3:1 turndown), PBC-40 (15.5–100 / 15.5–155 MBH, 4.0 GPM, 95.2%, 10.0:1) and PBC-52 (24.5–120 / 24.5–199 MBH, 5.2 GPM, 95.3%, 8.1:1) per the cut sheet (CUT-PBC R2, 8/22). The wall-hung boilers measure 16-13/16" wide (PBC-34/PBC-40) or 18-13/16" wide (PBC-52) per the dimension table, with a 4.75 GPM flow restrictor installed in the domestic circuit and a 0.30 GPM draw rate to initiate DHW demand (I&O manual).

Above 2,000 ft the boilers de-rate 3.5% per additional 1,000 ft with no adjustment to the boiler (I&O manual Table 12.2 note). Boilers.ca documents all three PBC models at model level from the I&O manual (PBC8013-R5, 3/24) and cut sheet. No official Canadian-sales statement was found — research reviewed US-site data only — so canadianStatus stays 'unknown'.

Highlights

  • Current Peerless gas combination (combi) boiler: PBC-34, PBC-40, PBC-52
  • 95.1–95.3% AFUE, ENERGY STAR certified; up to 10:1 turndown
  • Space heating 80/100/120 MBH maximum CH input plus DHW firing to 130/155/199 MBH
  • Up to 5.2 GPM domestic hot water at a 70°F rise (cut sheet)
  • Direct vent on 2" or 3" piping: PVC, CPVC, polypropylene or AL29-4C stainless
  • Wall-hung, stainless steel combi; 12-year limited residential heat exchanger warranty claim
  • Model-level pages published on Boilers.ca; I&O manual PBC8013-R5 and cut sheet linked here

Models

Series PBC (Peerless Combi) models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
15.5–80 MBH
Output (max)
—
AFUE
95.1 %

The Peerless Series PBC PBC-34 is the smallest combi in the current combi range: space heating at 15.5–80 MBH input with a DHW side firing 15.5–130 MBH, delivering 3.4 GPM at a 70°F rise at 95.1% AFUE on the wall-hung stainless platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
15.5–100 MBH
Output (max)
—
AFUE
95.2 %

The Peerless Series PBC PBC-40 is the 10:1-turndown middle size in the current combi range: space heating at 15.5–100 MBH input with a DHW side firing 15.5–155 MBH, delivering 4 GPM at a 70°F rise at 95.2% AFUE on the wall-hung stainless platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
24.5–120 MBH
Output (max)
—
AFUE
95.3 %

The Peerless Series PBC PBC-52 is the largest combi at up to 5.2 GPM in the current combi range: space heating at 24.5–120 MBH input with a DHW side firing 24.5–199 MBH, delivering 5.2 GPM at a 70°F rise at 95.3% AFUE on the wall-hung stainless platform.

Natural gasPropaneCombi

Compare models in this series

Comparison of Peerless Series PBC PBC-34 and Peerless Series PBC PBC-40 and Peerless Series PBC PBC-52
SpecificationPeerless Series PBC PBC-34Peerless Series PBC PBC-40Peerless Series PBC PBC-52
Space-heating (CH) input, minimum15.5 MBH15.5 MBH24.5 MBH
Space-heating (CH) input, maximum80 MBH100 MBH120 MBH
output-max———
Efficiency (AFUE)95.1 %95.2 %95.3 %
Turndown ratio8.3:110.0:18.1:1
vent-max-3———
vent-max-2———
weight———

Read the full comparison: Peerless Series PBC PBC-34 vs PBC-40 →

Read the full comparison: Peerless Series PBC PBC-40 vs PBC-52 →

Read the full comparison: Peerless Series PBC PBC-34 vs PBC-52 →

Error codes and alerts

Series PBC (Peerless Combi) alerts

  • 0PBC control
  • 1PBC control
  • 2PBC control
  • 3PBC control
  • 4PBC control
  • 5PBC control
  • 6PBC control
  • 7PBC control
  • 8PBC control
  • 9PBC control
  • 10PBC control
  • 11PBC control
  • 12PBC control
  • 15PBC control
  • 16PBC control
  • 17PBC control
  • 18PBC control
  • 19PBC control
  • 20PBC control
  • 21PBC control
  • 22PBC control
  • 23PBC control
  • 29PBC control
  • 30PBC control
  • 33PBC control
  • 38PBC control
  • 100PBC control
  • 101PBC control
  • 102PBC control
  • 103PBC control
  • 104PBC control
  • 105PBC control
  • 106PBC control
  • 107PBC control
  • 108PBC control
  • 109PBC control
  • 110PBC control
  • 111PBC control
  • 112PBC control
  • 113PBC control
  • 114PBC control
  • 115PBC control
  • 116PBC control
  • 118PBC control
  • 119PBC control
  • 120PBC control
  • 121PBC control
  • 122PBC control
  • 123PBC control
  • 125PBC control
  • 126PBC control
  • 127PBC control
  • 128PBC control
  • 129PBC control
  • 130PBC control
  • 132PBC control
  • 133PBC control
  • 134PBC control
  • 135PBC control
  • 155PBC control
  • 156PBC control
  • 162PBC control
  • 165PBC control
  • 166PBC control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Series PBC available in Canada?

No official Canadian-sales statement was found in the official pages and manuals reviewed on September 9, 2026 (US-site data only), so canadianStatus is recorded as 'unknown'. Confirm supply through a licensed distributor.

What is the difference between the three PBC models?

Maximum CH input steps from 80 MBH (PBC-34) to 100 MBH (PBC-40) and 120 MBH (PBC-52), DHW firing from 130 to 199 MBH, and DHW delivery from 3.4 to 5.2 GPM at a 70°F rise; AFUE climbs from 95.1% to 95.3% per the cut sheet.

Does the PBC need a chimney?

No — it is a direct-vent sealed-combustion combi boiler that vents through 2" or 3" approved pipe (PVC, CPVC, polypropylene or AL29-4C stainless) rather than a conventional chimney.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate