Skip to content
Boilers.caby ROMA Heating & Cooling

Raypak · Series

Raypak Hi Delta

The Hi Delta is Raypak's non-condensing copper finned-tube hydronic boiler with cast-iron headers, available indoor or outdoor on natural gas or propane, rated 84% efficiency on the page, in the 302C–2342C model family.

Current seriesunknownNatural gasPropanecommercial

Series facts

Type
non-condensing
Efficiency
84% thermal-efficiency
Fuel
Natural gas or propane; FlexGas dual-fuel variants are documented in a separate I&O (241295).
Venting
Unknown
Models documented
13
Warranty
Not verified

84% efficiency printed on the page hero; per-model ratings are published in Raypak submittals.

About the Hi Delta

Raypak presents the Hi Delta as a non-condensing copper finned-tube hydronic boiler with cast-iron headers, available in indoor and outdoor configurations, with '84% efficiency' printed in the page hero. FlexGas dual-fuel variants are documented in a separate I&O (241295).

The model family printed on the page is '302C-2342C' with model rows 302, 402, 502, 652, 752, 902, 992, 1262, 1532, 1802, 2002, 2072 and 2342.

Raypak publishes I&O manuals 241663 (302C–902C) and 241664 (992C–2342C), with submittals available from the page. No explicit Canadian-availability sentence appears.

Highlights

  • Non-condensing copper finned-tube hydronic boiler with cast-iron headers
  • 84% efficiency printed on the page hero
  • Indoor or outdoor models; natural gas or propane
  • Model family 302C–2342C (13 printed sizes)
  • I&O manuals 241663 and 241664 public

Models

Hi Delta models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
Output (max)
252 MBH
AFUE

The Raypak Hi Delta 302C is a non-condensing copper finned-tube commercial hydronic boiler rated 300 MBTUH input and 252 MBTUH Type H output at 84% thermal efficiency, with 2-stage (H3) firing and a 5 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
335 MBH
AFUE

The Raypak Hi Delta 402C is a non-condensing copper finned-tube commercial hydronic boiler rated 399 MBTUH input and 335 MBTUH Type H output at 84% thermal efficiency, with 2-stage (H3) firing and a 6 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
420 MBH
AFUE

The Raypak Hi Delta 502C is a non-condensing copper finned-tube commercial hydronic boiler rated 500 MBTUH input and 420 MBTUH Type H output at 84% thermal efficiency, with 2-stage (H3) firing and a 6 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
546 MBH
AFUE

The Raypak Hi Delta 652C is a non-condensing copper finned-tube commercial hydronic boiler rated 650 MBTUH input and 546 MBTUH Type H output at 84% thermal efficiency, with 2-stage (H3) firing and a 8 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
630 MBH
AFUE

The Raypak Hi Delta 752C is a non-condensing copper finned-tube commercial hydronic boiler rated 750 MBTUH input and 630 MBTUH Type H output at 84% thermal efficiency, with 2-stage (H3) firing and a 8 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
756 MBH
AFUE

The Raypak Hi Delta 902C is a non-condensing copper finned-tube commercial hydronic boiler rated 900 MBTUH input and 756 MBTUH Type H output at 84% thermal efficiency, with 2-stage (H3) firing and a 8 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
832 MBH
AFUE

The Raypak Hi Delta 992C is a non-condensing copper finned-tube commercial hydronic boiler rated 990 MBTUH input and 832 MBTUH Type H output at 84% thermal efficiency, with 3-stage (H8) firing and a 10 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,058 MBH
AFUE

The Raypak Hi Delta 1262C is a non-condensing copper finned-tube commercial hydronic boiler rated 1,260 MBTUH input and 1,058 MBTUH Type H output at 84% thermal efficiency, with 4-stage (H9) firing and a 12 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,285 MBH
AFUE

The Raypak Hi Delta 1532C is a non-condensing copper finned-tube commercial hydronic boiler rated 1,530 MBTUH input and 1,285 MBTUH Type H output at 84% thermal efficiency, with 4-stage (H9) firing and a 12 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,512 MBH
AFUE

The Raypak Hi Delta 1802C is a non-condensing copper finned-tube commercial hydronic boiler rated 1,800 MBTUH input and 1,512 MBTUH Type H output at 84% thermal efficiency, with 4-stage (H9) firing and a 14 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,679 MBH
AFUE

The Raypak Hi Delta 2002C is a non-condensing copper finned-tube commercial hydronic boiler rated 1,999 MBTUH input and 1,679 MBTUH Type H output at 84% thermal efficiency, with 4-stage (H9) firing and a 14 in flue collar.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,739 MBH
AFUE

The Raypak Hi Delta 2072C is a non-condensing copper finned-tube commercial hydronic boiler rated 2,070 MBTUH input and 1,739 MBTUH Type H output at 84% thermal efficiency, with 4-stage (H9) firing and a 14 in flue collar.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,966 MBH
AFUE

The Raypak Hi Delta 2342C is a non-condensing copper finned-tube commercial hydronic boiler rated 2,340 MBTUH input and 1,966 MBTUH Type H output at 84% thermal efficiency, with 4-stage (H9) firing and a 16 in flue collar.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Raypak Hi Delta 302C and Raypak Hi Delta 402C and Raypak Hi Delta 502C and Raypak Hi Delta 652C and Raypak Hi Delta 752C and Raypak Hi Delta 902C and Raypak Hi Delta 992C and Raypak Hi Delta 1262C and Raypak Hi Delta 1532C and Raypak Hi Delta 1802C and Raypak Hi Delta 2002C and Raypak Hi Delta 2072C and Raypak Hi Delta 2342C
SpecificationRaypak Hi Delta 302CRaypak Hi Delta 402CRaypak Hi Delta 502CRaypak Hi Delta 652CRaypak Hi Delta 752CRaypak Hi Delta 902CRaypak Hi Delta 992CRaypak Hi Delta 1262CRaypak Hi Delta 1532CRaypak Hi Delta 1802CRaypak Hi Delta 2002CRaypak Hi Delta 2072CRaypak Hi Delta 2342C
input-min
Input300 MBH399 MBH500 MBH650 MBH750 MBH900 MBH990 MBH1,260 MBH1,530 MBH1,800 MBH1,999 MBH2,070 MBH2,340 MBH
Output252 MBH335 MBH420 MBH546 MBH630 MBH756 MBH832 MBH1,058 MBH1,285 MBH1,512 MBH1,679 MBH1,739 MBH1,966 MBH
afue
turndown
vent-max-3
vent-max-2
Weight380 lb445 lb545 lb590 lb675 lb740 lb900 lb1,010 lb1,225 lb1,350 lb1,450 lb1,450 lb1,520 lb

Read the full comparison: Raypak Hi Delta 302C vs Hi Delta 402C

Read the full comparison: Raypak Hi Delta 502C vs Hi Delta 652C

Read the full comparison: Raypak Hi Delta 902C vs Hi Delta 992C

Read the full comparison: Raypak Hi Delta 1802C vs Hi Delta 2002C

Error codes and alerts

Hi Delta alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Hi Delta condensing?

No. Raypak lists Hi Delta under its non-condensing hydronic boilers: copper finned-tube with cast-iron headers and 84% efficiency printed on the page.

What sizes does the Hi Delta come in?

The page prints the 302C–2342C family with model rows 302, 402, 502, 652, 752, 902, 992, 1262, 1532, 1802, 2002, 2072 and 2342.

Can a Hi Delta run on propane?

The page lists natural gas or propane, and FlexGas dual-fuel variants are documented in Raypak I&O 241295.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate