Skip to content
Boilers.caby ROMA Heating & Cooling

Raypak · Series

Raypak XFIIRE

The XFIIRE is Raypak's condensing commercial hydronic boiler in six sizes — H7-300B through H7-1000B (300–1000 MBTUH) — with up to 96.5% AHRI thermal efficiency, 7:1 turndown, Category IV venting and VERSA IC controls with cascade up to eight boilers.

Current seriesunknownNatural gascommercial

Series facts

Type
condensing
Efficiency
96.5% thermal-efficiency
Fuel
Natural gas per the captured page; propane configuration is not reprinted on the captured text.
Venting
Category IV (condensing) venting per the product page model data.
Models documented
6
Warranty
Not verified

The page's model data prints 96.5% AHRI thermal efficiency for the H7-300B and 96% for the remaining sizes; per-model values are in the 241854 submittal.

About the XFIIRE

Raypak's XFIIRE page presents the line as a condensing hydronic boiler with model sizes H7-300B, H7-400B, H7-500B, H7-650B, H7-800B and H7-1000B. The product-page model data prints 300 to 1,000 MBTUH input, 96.5% AHRI thermal efficiency on the 300B and 96% on the other sizes, 7:1 turndown, Category IV venting, 120/208 VAC single-phase power and maximum water flows from 38 to 90 gpm.

Product submittal 241854 prints the full rating table: inputs 300/399/500/650/800/1,000 MBTUH against outputs 289/383/480/624/768/960 MBTUH, water connections 2 in NPT (2-1/2 in on the 1000B), flue and air connections from 4 in to 6 in, gas connections 1 in to 1-1/4 in NPT, and shipping weights 411 to 627 lb. The line runs the VERSA IC control with Raymote connectivity and supports cascade up to eight boilers.

Raypak publishes I&O manual 241941 in English and French, the 241854 submittal and the 1100.15 XFIIRE brochure as public downloads from the product page. No explicit Canadian-availability sentence appears on the captured page.

Highlights

  • Condensing commercial hydronic boiler, 300 – 1,000 MBTUH
  • Models H7-300B, H7-400B, H7-500B, H7-650B, H7-800B, H7-1000B
  • 96.5% AHRI thermal efficiency (300B) and 96% on the other sizes (page model data)
  • 7:1 turndown; Category IV venting; 120/208 VAC single-phase
  • VERSA IC control with cascade up to 8 boilers
  • I&O manual 241941 public in English and French; submittal 241854 for ratings

Models

XFIIRE models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
Output (max)
289 MBH
AFUE

The Raypak XFIIRE H7-300B is a condensing commercial hydronic boiler rated 300 MBTUH input and 289 MBTUH output at 96.5% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and 38 gpm maximum flow per submittal 241854.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
383 MBH
AFUE

The Raypak XFIIRE H7-400B is a condensing commercial hydronic boiler rated 399 MBTUH input and 383 MBTUH output at 96% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and 50 gpm maximum flow per submittal 241854.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
480 MBH
AFUE

The Raypak XFIIRE H7-500B is a condensing commercial hydronic boiler rated 500 MBTUH input and 480 MBTUH output at 96% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and 62 gpm maximum flow per submittal 241854.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
624 MBH
AFUE

The Raypak XFIIRE H7-650B is a condensing commercial hydronic boiler rated 650 MBTUH input and 624 MBTUH output at 96% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and 80 gpm maximum flow per submittal 241854.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
768 MBH
AFUE

The Raypak XFIIRE H7-800B is a condensing commercial hydronic boiler rated 800 MBTUH input and 768 MBTUH output at 96% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and 90 gpm maximum flow per submittal 241854.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
960 MBH
AFUE

The Raypak XFIIRE H7-1000B is a condensing commercial hydronic boiler rated 1000 MBTUH input and 960 MBTUH output at 96% AHRI thermal efficiency, with 7:1 turndown, Category IV venting and 90 gpm maximum flow per submittal 241854.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Raypak XFIIRE H7-300B and Raypak XFIIRE H7-400B and Raypak XFIIRE H7-500B and Raypak XFIIRE H7-650B and Raypak XFIIRE H7-800B and Raypak XFIIRE H7-1000B
SpecificationRaypak XFIIRE H7-300BRaypak XFIIRE H7-400BRaypak XFIIRE H7-500BRaypak XFIIRE H7-650BRaypak XFIIRE H7-800BRaypak XFIIRE H7-1000B
input-min
Input300 MBH399 MBH500 MBH650 MBH800 MBH1,000 MBH
Output289 MBH383 MBH480 MBH624 MBH768 MBH960 MBH
afue
Turndown7:17:17:17:17:17:1
vent-max-3
vent-max-2
Weight411 lb411 lb416 lb501 lb547 lb627 lb

Read the full comparison: Raypak XFIIRE H7-300B vs XFIIRE H7-400B

Read the full comparison: Raypak XFIIRE H7-400B vs XFIIRE H7-500B

Read the full comparison: Raypak XFIIRE H7-500B vs XFIIRE H7-650B

Read the full comparison: Raypak XFIIRE H7-800B vs XFIIRE H7-1000B

Error codes and alerts

XFIIRE alerts

  • OUTLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • INLET SENVERSA IC control with PIM (error items shown on the touchscreen display)
  • GAS PRESSVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGNITIONVERSA IC control with PIM (error items shown on the touchscreen display)
  • LIMIT TRIPVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLAMEVERSA IC control with PIM (error items shown on the touchscreen display)
  • ID CARDVERSA IC control with PIM (error items shown on the touchscreen display)
  • IGN CTRLVERSA IC control with PIM (error items shown on the touchscreen display)
  • DELTA TVERSA IC control with PIM (error items shown on the touchscreen display)
  • LOW 24VACVERSA IC control with PIM (error items shown on the touchscreen display)
  • BLOW SPEEDVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLOW ERRORVERSA IC control with PIM (error items shown on the touchscreen display)
  • UNDER FLOWVERSA IC control with PIM (error items shown on the touchscreen display)
  • FLOW WARNINGVERSA IC control with PIM (error items shown on the touchscreen display)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the XFIIRE come in?

Six sizes: H7-300B, H7-400B, H7-500B, H7-650B, H7-800B and H7-1000B, i.e. 300 to 1,000 MBTUH input.

Is the XFIIRE condensing?

Yes. Raypak lists the XFIIRE under its condensing hydronic boilers, with Category IV venting and 96–96.5% AHRI thermal efficiency printed in the product-page model data.

What efficiency does the XFIIRE achieve?

The product page prints 96.5% AHRI thermal efficiency for the H7-300B and 96% for the other five sizes; submittal 241854 carries the full rating table.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate