Skip to content
Boilers.caby ROMA Heating & Cooling

Rheem / Ruud (commercial) · IKONIC Commercial Condensing Tankless

Ruud RUTGH-CS11i

The Ruud RUTGH-CS11i is the base version of the IKONIC Commercial Condensing Tankless water heater — a commercial DHW-only appliance rated 11,000–199,900 BTU/h, 11.2 GPM and 0.96 UEF, not a boiler.

CurrentCanadian status unknown

Key figures

Max input
199,900 BTU/h
Max CSA output
AFUE
Min input
11,000 BTU/h
Natural gasPropaneDHW-only (tankless)commercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Ruud RUTGH-CS11i in practice

Per the official Ruud brochure and the shared RTGH-CS(R)11i specification sheet, the RUTGH-CS11i fires from 11,000 to 199,900 BTU/h on natural gas or propane, delivers up to 11.2 GPM at a 35°F rise (8.8 GPM at 45°F, 5.9 GPM at 67°F), is rated 0.96 UEF and is ENERGY STAR qualified. It installs indoors as standard, with the RTGH-SX outdoor conversion kit sold separately, and operates at altitudes up to 10,200 ft without component changes.

The RUTGH-CS11i is the base model without a factory recirculation pump. It weighs 77.6 lb; a recirculation loop can be added in the field, or the CSR model can be specified for a factory pump.

The unit is a down-fire, pre-mix sealed-combustion water heater with a 444 stainless-steel tube-fin primary heat exchanger and a brazed-plate 304 stainless-steel secondary, a threaded condensate trap, and manifold capability up to 32 units with common venting up to 12. It is certified to CSA/ANSI Z21.10.3:19 and carries an 8-year limited heat-exchanger, 5-year parts and 1-year labor warranty. This is a domestic-hot-water appliance, not a boiler; Rheem-family commercial boilers are the Raypak lines.

Best suited to

  • Commercial domestic hot water at up to 199,900 BTU/h per unit
  • Buildings pairing the heater with a field-installed recirculation loop or no recirculation
  • Manifolded plants: up to 32 units without external control, common venting up to 12

Applicability and support

Model number
RUTGH-CS11i
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rheem / Ruud (commercial). Units are shown with every value; notes flag conflicting sources or missing figures.

Ruud RUTGH-CS11i specifications
SpecificationValueNote
Input
Input, maximum199,900 BTU/hAs printed in the official Rheem/Ruud brochures and the RTGH-CS(R)11i specification sheet (Rev. 01, 11-14-2025).
Input, minimum11,000 BTU/h
Efficiency
Uniform Energy Factor (UEF)0.96 UEF0.96 UEF; ENERGY STAR qualified per the official product pages and brochures.
Domestic hot water
Flow at 35°F rise11.2 GPM
Flow at 45°F rise8.8 GPM
Flow at 67°F rise5.9 GPM
Minimum activation flow0.4 GPM activation / 0.26 GPM continuous
Venting and air
VentingSchedule 40 PVC, CPVC or polypropylene; 2" or 3"; 70 ft (2") / 150 ft (3") single run; common vent up to 12 units
Physical and connections
Weight77.6 lbAs printed in the official brochure model table.
Heat exchangerPrimary: 444 stainless steel tube-fin; secondary: brazed-plate 304 stainless steelPer the RTGH-CS(R)11i specification sheet; the brochures summarize as stainless/stainless.
Dimensions (H × W × D)28-9/16 × 17-5/16 × 13-11/16 in
Electrical
Power supply120 V, 60 Hz
Operating limits and other
RecirculationNo built-in recirculation pumpA recirculation loop can be added in the field; the CSR models carry the pump from the factory.
Temperature range85°F – 185°F (factory setting 120°F; max inlet return 140°F)
FuelNatural gas or LP; ships NG with LP conversion kit included
InstallationIndoor; outdoor conversion kit RTGH-SX sold separately
Maximum altitude10,200 ft without component changes
NOxUltra-Low NOx, meets 14 ng/J; SCAQMD Rule 1146.2 compliant
Manifold capabilityUp to 32 units without external control
Warranty8-year limited heat exchanger / 5-year limited parts / 1-year limited labor

Frequently asked questions

Is the RUTGH-CS11i a boiler?

No. It is a commercial condensing tankless water heater (DHW-only). Rheem's commercial product tree contains no boiler category; commercial boilers in the Rheem family are the Raypak lines.

What are the RUTGH-CS11i ratings?

11,000–199,900 BTU/h input, up to 11.2 GPM at a 35°F rise, 0.96 UEF and ENERGY STAR, per the official brochure and specification sheet.

Can this model recirculate hot water?

Not from the factory. The base model has no built-in pump; specify the CSR version for a factory pump, or add a recirculation loop in the field.

Questions about the Ruud RUTGH-CS11i?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate