Skip to content
Boilers.caby ROMA Heating & Cooling

U.S. Boiler Company · ES2

U.S. Boiler Company ES2 ES27

The U.S. Boiler Company ES2 ES27 is the first size with a 3/4-inch gas valve and 7-inch vent: 210 MBH input with 178 MBH DOE heating capacity and a 155 MBH net AHRI water rating at 85.0% AFUE, chimney vented in 7" on the IQ Control System.

CurrentCanadian status unknown

Key figures

Max input
210 MBH
Max CSA output
AFUE
85 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

U.S. Boiler Company ES2 ES27 in practice

The ES2 ES27 is a cast-iron, chimney-vented gas water boiler rated at 210 MBH input. Its row in the ES2 Product Data Sheet (Form HYDL09081) prints 178 MBH DOE heating capacity, a 155 MBH net AHRI water rating at a 1.15 piping and pickup allowance, and 85.0% AFUE, with a 7" vent and 6 gallons of boiler water.

The boiler ships at approximately 464 lb and measures 24-3/4" wide by 41 inches high by 33 inches deep, connecting on 1-1/4" supply and return with a 3/4" gas valve. Standard equipment includes the Intelligent Hydronic Control with a three-digit status/error readout, the IQ Option Panel for plug-and-play outdoor reset with DHW priority, low water cutoff and auxiliary high limit, a step-opening redundant gas valve, stainless-steel flue baffles, spark ignition with retry, a circulator and a resettable blocked vent switch. Ratings are certified to 2,000 feet and decrease three percent per 1,000 feet above that, with altitude kits required above 5,400 feet.

Boilers.ca documents this size at model level from the ES2 Product Data Sheet and links the published I&O manual. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 210 MBH residential heat-loss loads
  • Replacement installations in homes with an existing chimney
  • Owners wanting the IQ Option Panel's plug-and-play outdoor reset

Applicability and support

Model number
ES27
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by U.S. Boiler Company. Units are shown with every value; notes flag conflicting sources or missing figures.

U.S. Boiler Company ES2 ES27 specifications
SpecificationValueNote
Input
Input210 MBHInput rating per the ES2 Product Data Sheet ratings table (sea level to 2,000 ft; ratings decrease three percent per 1,000 ft above that).
Output
DOE heating capacity178 MBHDOE heating capacity per the ES2 Product Data Sheet ratings table.
Net AHRI water rating155 MBHNet AHRI water rating per the ES2 Product Data Sheet, based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)85 %85.0% AFUE per the ES2 Product Data Sheet ratings table; the product page carries an 85% AFUE headline.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent size7"Vent size per the ES2 Product Data Sheet ratings table; the boiler is chimney vented with an integrated draft diverter, damper and connector included.
VentingChimney vented (natural draft) with integrated draft diverterThe ES2 is designed for homes with existing chimneys; altitude conversion kits are required above 5,400 feet (kits do not convert gas type).
Physical and connections
Approx. shipping weight464 lbApproximate shipping weight per the ES2 Product Data Sheet ratings table.
Dimensions (width × height × depth)24-3/4" × 41" × 33"ES2 dimension table values; height and depth are common across the line.
Boiler water content6 galWater content per the ES2 Product Data Sheet dimensions and connections table.
Supply/return connections1-1/4" supply and 1-1/4" returnWater connection sizes per the ES2 Product Data Sheet connections table.
Gas valve connection3/4"Gas valve connection per the ES2 Product Data Sheet connections table.
Operating limits and other
ControlIntelligent Hydronic Control with three-digit readout and IQ Option PanelCombines aquastat, relay and ignition functions; the IQ Option Panel accepts plug-and-play IQ Option Cards for outdoor reset with DHW priority, low water cutoff and auxiliary high limit.
FuelNatural gas or LP gasAvailable for natural or LP gas per the ES2 Product Data Sheet ratings note.

Frequently asked questions

What are the ES2 ES27's ratings?

210 MBH input, 178 MBH DOE heating capacity, a 155 MBH net AHRI water rating and 85.0% AFUE with a 7" vent per the ES2 Product Data Sheet.

Does the ES2 ES27 need a chimney?

Yes — the ES2 is a chimney-vented natural-draft boiler with an integrated draft diverter; this size lists a 7" vent. Homes without a chimney are the use case for the power-vented PVG line.

Questions about the U.S. Boiler Company ES2 ES27?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate