Utica Boilers · PEG-E (Gas Steam)

Utica PEG299EID

The Utica PEG299EID is a gas-fired cast-iron steam boiler: 299 MBH input, 250 MBH heating capacity, 188 MBH net steam and 782 sq ft at 83.4% AFUE, with 9 sections, a 7" vent and (2) 2" piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

CurrentCanadian status unknown

Key figures

Max input
Max CSA output
AFUE
83.4 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Utica PEG299EID in practice

The PEG299EID is one of the seven PEG-E gas-fired cast-iron steam sizes Utica prints: 299 MBH input for 250 MBH heating capacity and 188 MBH net steam and 782 sq ft at 83.4% AFUE. The official sell-sheet ratings table prints 9 cast-iron sections, a 7" vent pipe, 30⅜ × 35⅞ × 30⅜ in cabinet dimensions and a 736 lb shipping weight for this size.

It is a non-condensing atmospheric chimney-vent design with a rear-mounted integral draft hood and vent damper, a cast-iron heat exchanger with cast-iron push nipples, stainless steel burners, and 2" NPT return and supply with two supply and two return tappings. Gas is ¾" NPT; electrical is 120 V AC at under 12 A. The IOM near-boiler piping figures print (2) 2" for this section count, and the product page describes single and dual piping riser options depending on boiler size.

Steam controls include probe-type lwco with pressure high-limit control, pressure gauge and gauge glass. Utica prints a 12-year non-prorated limited residential warranty plus 5-year parts, and the official Gas Boilers category card carries the 'Current' tag (checked 2026-09-09). The IOM contains no discrete fault-code or LED-diagnostic table for these steam boilers — troubleshooting is mechanical/pressure oriented — and gas, steam and venting work belongs with a licensed contractor.

Best suited to

  • Steam-heated buildings whose radiation load fits 188 MBH of net steam capacity
  • Low-clearance installations that suit the low-profile atmospheric design
  • Owners of an installed PEG identifying their size and documentation

Applicability and support

Model number
PEG299EID
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Utica Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Utica PEG299EID specifications
SpecificationValueNote
Input
Input299 MBHFixed input in MBH as printed in the official sell-sheet ratings table; the PEG does not modulate.
Output
Heating capacity250 MBHHeating capacity as printed in the official sell-sheet ratings table.
Net AHRI steam rating188 MBHNet AHRI steam rating based on a piping and pickup allowance of 1.333, as printed in the official sell-sheet ratings table.
Steam radiation782 sq ftSteam square feet as printed in the official sell-sheet ratings table.
Efficiency
AFUE83.4 %AFUE as printed for this size in the official sell-sheet ratings table.
Venting and air
Vent pipe size7"Vent pipe size as printed in the official sell-sheet ratings table; atmospheric chimney vent with integral draft hood and vent damper.
VentingAtmospheric chimney vent — rear-mounted integral draft hood with vent damperLow-profile, compact design for low-clearance installations, per the product page.
Physical and connections
Cast-iron sections9Section count as printed in the official sell-sheet ratings table; cast-iron sections with cast-iron push nipples.
Dimensions (W x H x D)30⅜ × 35⅞ × 30⅜Cabinet dimensions in inches as printed in the official sell-sheet ratings table.
Shipping weight736 lbShipping weight in pounds as printed in the official sell-sheet ratings table.
BurnersStainless steel burnersAs printed on the official product page.
Heat exchangerCast iron with cast-iron push nipplesAs printed on the official product page.
Operating limits and other
Piping risers(2) 2"Near-boiler piping minimum dimensions per the official IOM figures; the product page describes single and dual piping riser options depending on boiler size.
Connections2" NPT return and supply with two supply and two return tappings; gas ¾" NPT; 120 V AC, <12 AAs printed in the official sell sheet; steam ratings use a piping and pickup allowance of 1.333.
Steam controlsProbe-type LWCO with pressure high-limit control, pressure gauge and gauge glassAs printed on the official product page and in the official sell sheet.
Warranty12-year non-prorated limited residential warranty plus 5-year partsAs printed on the official product page and sell sheet.

Manuals

Alerts documented for this model

None documented yet.

Services

Frequently asked questions

What are the PEG299EID's ratings?

299 MBH input, 250 MBH heating capacity, 188 MBH net steam and 782 sq ft of net steam at 83.4% AFUE, with 9 sections, per the official sell-sheet ratings table.

What piping risers does the PEG299EID use?

The IOM near-boiler piping figures print (2) 2" for this section count; the product page describes single and dual piping riser options depending on boiler size.

Is the PEG299EID a condensing boiler?

No — it is a non-condensing cast-iron steam boiler with atmospheric chimney venting, an integral draft hood and a vent damper.

Questions about the Utica PEG299EID?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate