The PEG-F is Utica's current gas-fired cast-iron STEAM boiler line: seven sizes from 75 to 299 MBH at 82.0–82.7% AFUE, atmospheric chimney venting through a front-mounted integral draft hood and vent damper, 2½" NPT supply and return connections with two tappings each, electronic low water cut-off with a ¾" probe, and a 12-year non-prorated residential warranty plus 5-year parts.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
82.7% AFUE
Fuel
Natural gas or propane: the sell-sheet ratings table prints NG/LP pairs for every size, and the product page lists natural-gas and propane conversion kits plus high-altitude conversion kits.
Venting
Atmospheric chimney vent — front-mounted integral draft hood with a vent damper; low-profile, compact design for low-clearance installations.
Models documented
7

Up to 82.7% AFUE as printed on the product page; the official sell-sheet table prints 82.0% for six sizes and 82.7% for the PEG075FID.

About the PEG-F (Gas Steam)

The PEG-F is Utica's current gas-fired cast-iron steam boiler line, tagged 'Current' on the official Gas Boilers category page (checked 2026-09-09). Utica describes seven sizes from 75 MBH to 299 MBH with up to 82.7% AFUE, a one-piece easy-to-remove front panel concealing the electronic ignition control, a cast-iron heat exchanger with cast-iron push nipples, titanium burners, and a front-mounted integral draft hood and vent damper in a low-profile, low-clearance design.

The official sell sheet (PN 700000004 Rev. 09/04/26) prints the seven sizes with NG/LP pairs: PEG075FID (75/70 MBH input, 62/58 MBH heating capacity, 47/44 MBH net steam, 195/183 sq ft, 82.7% AFUE, 3 sections, 5" vent), PEG112FID (112/105, 91/85, 68/64, 283/267, 82.0, 4, 6"), PEG150FID (150/140, 122/114, 92/86, 383/358, 82.0, 5, 6"), PEG187FID (187/175, 153/143, 115/107, 479/446, 82.0, 6, 7"), PEG225FID (225/210, 183/171, 137/128, 570/533, 82.0, 7, 7"), PEG262FID (262/245, 214/200, 161/150, 670/625, 82.0, 8, 7") and PEG299FID (299/280, 245/229, 184/172, 766/717, 82.0, 9, 7"). Dimensions run 11¼"–30¾" wide × 36⅜" high × 26½" deep, shipping 297–736 lb.

Return and supply are 2½" NPT with two supply and two return tappings on both sides; gas is ½" NPT on the 075/112/150 and ¾" NPT from the 187 up; electrical is 120 V AC at under 12 A, and steam ratings use a piping and pickup allowance of 1.333. The product page describes '2 1/2 inch single and dual piping risers' depending on boiler size, while the IOM near-boiler piping figures print minimum 2" risers (single for the 3/4-section sizes, (2) 2" for the 5–9-section sizes) — both official wordings are captured here. Controls include an electronic low water cut-off with a ¾" probe, pressure limit control, steam pressure gauge and glass water level gauge; a factory-tapped ½" NPT location is provided for a secondary manual-reset LWCO. Utica prints a 12-year non-prorated residential warranty plus 5-year parts, and gas, steam and venting work belongs with a licensed contractor.

Highlights

  • Current on Utica's Gas Boilers category page (checked 2026-09-09)
  • Seven steam sizes — PEG075FID through PEG299FID — inputs 75–299 MBH NG (70–280 MBH LP), AFUE 82.0–82.7%
  • Cast-iron heat exchanger with cast-iron push nipples; titanium burners; 3–9 sections
  • Atmospheric chimney vent with front-mounted integral draft hood and vent damper
  • 2½" NPT supply and return with two tappings each; electronic LWCO with ¾" probe, pressure limit, gauge glass
  • 12-year non-prorated residential warranty + 5-year parts; NG/LP ratings printed for every size

12-year non-prorated limited warranty (residential) plus 5-year parts, as printed on the PEG-F sell sheet and product page.

Models

PEG-F (Gas Steam) models

One canonical page per model with input, output and efficiency kept separate.

Utica Boilers

Utica PEG075FID

CurrentCanadian status unknown
Input
Output (max)
AFUE
82.7 %

The Utica PEG075FID is a gas-fired cast-iron steam boiler: 75/70 MBH input (NG/LP), 62/58 MBH heating capacity, 47/44 MBH net steam and 195/183 sq ft at 82.7% AFUE, with 3 sections, a 5" vent and 2" (single) piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica PEG112FID

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Utica PEG112FID is a gas-fired cast-iron steam boiler: 112/105 MBH input (NG/LP), 91/85 MBH heating capacity, 68/64 MBH net steam and 283/267 sq ft at 82% AFUE, with 4 sections, a 6" vent and 2" (single) piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica PEG150FID

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Utica PEG150FID is a gas-fired cast-iron steam boiler: 150/140 MBH input (NG/LP), 122/114 MBH heating capacity, 92/86 MBH net steam and 383/358 sq ft at 82% AFUE, with 5 sections, a 6" vent and (2) 2" piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica PEG187FID

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Utica PEG187FID is a gas-fired cast-iron steam boiler: 187/175 MBH input (NG/LP), 153/143 MBH heating capacity, 115/107 MBH net steam and 479/446 sq ft at 82% AFUE, with 6 sections, a 7" vent and (2) 2" piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica PEG225FID

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Utica PEG225FID is a gas-fired cast-iron steam boiler: 225/210 MBH input (NG/LP), 183/171 MBH heating capacity, 137/128 MBH net steam and 570/533 sq ft at 82% AFUE, with 7 sections, a 7" vent and (2) 2" piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica PEG262FID

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Utica PEG262FID is a gas-fired cast-iron steam boiler: 262/245 MBH input (NG/LP), 214/200 MBH heating capacity, 161/150 MBH net steam and 670/625 sq ft at 82% AFUE, with 8 sections, a 7" vent and (2) 2" piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica PEG299FID

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Utica PEG299FID is a gas-fired cast-iron steam boiler: 299/280 MBH input (NG/LP), 245/229 MBH heating capacity, 184/172 MBH net steam and 766/717 sq ft at 82% AFUE, with 9 sections, a 7" vent and (2) 2" piping risers. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Utica PEG075FID and Utica PEG112FID and Utica PEG150FID and Utica PEG187FID and Utica PEG225FID and Utica PEG262FID and Utica PEG299FID
SpecificationUtica PEG075FIDUtica PEG112FIDUtica PEG150FIDUtica PEG187FIDUtica PEG225FIDUtica PEG262FIDUtica PEG299FID
input-min
input-max
output-max
AFUE82.7 %82 %82 %82 %82 %82 %82 %
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Utica PEG075FID vs Utica PEG112FID

Read the full comparison: Utica PEG112FID vs Utica PEG150FID

Read the full comparison: Utica PEG150FID vs Utica PEG187FID

Read the full comparison: Utica PEG187FID vs Utica PEG225FID

Error codes and alerts

PEG-F (Gas Steam) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Utica PEG-F cover?

Seven sizes as printed in the official sell sheet: PEG075FID, PEG112FID, PEG150FID, PEG187FID, PEG225FID, PEG262FID and PEG299FID, from 75 to 299 MBH natural-gas input (70–280 MBH on LP) with 82.0–82.7% AFUE.

How does the PEG-F differ from the PEG-E?

Both are seven-size cast-iron gas steam lines from 75 to 299 MBH. The PEG-F uses a front-mounted integral draft hood, 2½" NPT supply/return connections, titanium burners and an electronic low water cut-off with a ¾" probe; the PEG-E uses a rear-mounted integral draft hood, 2" NPT connections, stainless steel burners and a probe-type LWCO. The PEG-E prints the higher AFUE range (82.2–83.4% vs 82.0–82.7%).

What piping risers does the PEG-F use?

The product page prints '2 1/2 inch single and dual piping risers' depending on boiler size; the IOM near-boiler piping figures print minimum 2" risers — a single 2" riser for the 3- and 4-section sizes and (2) 2" risers for the 5- through 9-section sizes. Both official wordings are captured.

Is the PEG-F available on propane?

Yes — the official sell-sheet ratings table prints natural-gas and LP figures for every size (for example, the PEG075FID at 75 MBH NG / 70 MBH LP), and propane conversion kits are listed on the product page.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate