Weil-McLain SF2000

The Weil-McLain SF2000 is a current commercial condensing gas boiler in the SlimFit line: 333–2000 MBH input, 1906 MBH gross output and a 1657 MBH net printed page rating at up to 96.1% combustion efficiency, with 8" venting and a sectional aluminium block heat exchanger.

CurrentCanadian status unknown

Key figures

Max input
2,000 MBH
Max CSA output
AFUE
Min input
333 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Weil-McLain SF2000 in practice

The SF2000 is one of the five current SlimFit commercial condensing gas sizes documented on Weil-McLain's official SlimFit page. Its Technical Specs row prints 333–2000 MBH input, 1906 MBH gross output and 1657 MBH in the net column (the official 1000–2000 submittal prints no per-size net column — both sources are recorded as printed). Venting is 8" with 100 ft allowable length in PVC, CPVC, PP, ABS or AL29-4C, on 2" NPT male gas at 3"–14" w.c. and 3" ASME Class 150 supply/return connections.

The boiler uses a sectional aluminium block heat exchanger with a stainless steel woven-fiber burner, sealed combustion, direct spark ignition, a variable-speed blower and a negative-pressure regulated gas valve; the submittal prints 96.1% combustion efficiency and null% thermal efficiency for this size. Control is the SlimFit platform with a 3.5 in. LCD screen, preset heating systems, 0-10 VDC output, Modbus standard and BACnet optional, cascading up to eight boilers with lead/lag rotation and up to 24 zone inputs/outputs.

Boilers.ca records the printed spec row for the SF2000 for commercial service planning. No official Canadian-sales statement was found on the US product page reviewed, so canadianStatus stays 'unknown'; commercial gas, combustion and venting work belongs with a licensed contractor against the model's own SlimFit boiler manual.

Best suited to

  • 333–2000 MBH commercial condensing loads
  • Plants wanting a sectional aluminium block boiler with cascade control
  • Buildings planning 8-boiler lead/lag systems with up to 24 zones

Applicability and support

Model number
SF2000
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.

Weil-McLain SF2000 specifications
SpecificationValueNote
Input
Maximum input2,000 MBHMaximum input per the official SlimFit Technical Specs table.
Minimum input333 MBHMinimum input per the official SlimFit Technical Specs table.
Output
Gross output1,906 MBHGross output per the official SlimFit Technical Specs table.
Net AHRI rating1,657 MBHNet AHRI rating as printed on the official page's Technical Specs table.
Efficiency
Combustion efficiency96.1 %The SlimFit 1000–2000 submittal prints 'up to 96.1% combustion efficiency' among the standard features; no per-size efficiency column is printed for these sizes.
Thermal efficiencyNot printed per sizeThe 1000–2000 submittal does not print a per-size thermal-efficiency column; the series record keeps efficiency null.
Domestic hot water
Domestic hot waterHeating-only commercial boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent/air diameter and length8"; 100 ftVent material PVC, CPVC, PP, ABS or AL29-4C per the Technical Specs table; certified Category II/IV venting.
Physical and connections
Gas connection and pressure2" NPT male; 3"–14" w.c.Gas connection size and min/max gas pressure per the Technical Specs table.
Supply / return water connections3" ASME Class 150Supply/return water connection per the Technical Specs table.
Operating limits and other
Turn-down ratio6:1The SlimFit 1000–2000 submittal prints a modulating burner with 6:1 turndown; the 550–750 submittal documents the same sectional aluminium block platform.
ControlSlimFit control with 3.5" LCD screen; Modbus standard, BACnet optionalPer the 550–750 submittal: preset typical heating systems, 0-10 VDC output, up to 8-boiler cascading with lead/lag rotation, up to 24 zones.
Heat exchangerSectional aluminum block with stainless steel burner (woven steel fiber mesh)Per the SlimFit 1000–2000 submittal standard features; sealed combustion, direct spark ignition, variable-speed blower and negative-pressure regulated gas valve.
FuelNatural gas; optional LP on the smaller sizes per the pageThe official page notes optional LP on the smaller sizes.

Frequently asked questions

What are the SF2000's ratings?

333–2000 MBH input and 1906 MBH gross output per the official Technical Specs table.

What venting does the SF2000 use?

8" vent/air connections with 100 ft allowable length in PVC, CPVC, PP, ABS or AL29-4C; the line is certified for Category II and Category IV venting.

How many SlimFit boilers can cascade?

Up to eight boilers with lead/lag rotation per the submittal, with multiple system functionality, series/parallel or smart sequencing and up to 24 zone inputs/outputs.

Questions about the Weil-McLain SF2000?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate