Skip to content
Boilers.caby ROMA Heating & Cooling

Weil-McLain · Series

Weil-McLain CGa (cast iron)

The CGa is Weil-McLain's cast iron atmospheric boiler, discontinued in Canada after the June 30, 2023 production cut-off announced in Weil-McLain Canada's April 2023 news release; Canadian units are the Series-3-era generation (52-245 MBH), while the US still sells the Series 4.

discontinuedhistoricalNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84% AFUE
Fuel
Natural gas or propane; the CA product page lists propane with a conversion kit needed.
Venting
Category I, B-vent, vertical (chimney) vent only per the CA discontinued page; 50 psi relief option noted.
Models documented
7
Warranty
Not verified

CA page: up to 84% AFUE, for the Series-3-era Canadian units; the US CGa Series 4 manual also lists 84.0% AFUE for its different model set.

About the CGa (cast iron)

The CGa is a cast iron, natural-draft boiler that the CA page describes with Category I B-vent vertical chimney venting only, an up-to-84% AFUE rating and residential coverage of 20 years on the heat exchanger. Canada sold it in seven sizes from 52 to 245 MBH input — the Series-3-era generation — and its Discontinued-page note says production was phased out under the federal efficiency standard with an effective date of June 30.

Weil-McLain Canada's news release of April 27, 2023 is explicit: the CGa and CGi were phased out in response to federal efficiency standards that placed a production cut-off date (not a sale or installation date) of June 30, 2023 on non-condensing gas-fired residential boilers under 300,000 BTUH. Contractors could keep buying and installing after that date while stock lasted, and Weil-McLain Canada promised parts availability for at least 20+ years.

Generation matters when servicing a Canadian CGa: the CA page data (inputs 52-245 MBH, "vertical vent only") corresponds to the older Series 3 generation, while the US continues to sell the CGa Series 4 with a different model set (inputs 38-233 MBH) and a 2025 manual. The current US manual has no Canada-specific B149 wording because the CGa is no longer sold new in Canada.

Highlights

  • Cast iron atmospheric boiler; Canada's discontinued CGa was Series-3 era
  • Seven Canadian sizes, 52-245 MBH, up to 84% AFUE
  • Production cut-off June 30, 2023 (CA news release, Apr 27 2023)
  • Parts availability promised for at least 20+ years
  • Category I B-vent, vertical vent only
  • US still sells the different CGa Series 4 generation

Models

CGa (cast iron) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedHistorically in Canada
Input
—
Output (max)
32 MBH
AFUE
84 %

The CGa-25 is the smallest CGa Series 4 size, documented from the US-current generation of the cast iron boiler that Canada discontinued in 2023: 38 MBH CSA input, 32 MBH DOE heating capacity and 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
—
Output (max)
56 MBH
AFUE
84 %

The CGa-3 is the second-smallest CGa Series 4 size of the cast iron boiler line Canada discontinued in 2023: 67 MBH CSA input, 56 MBH DOE heating capacity and 84% AFUE, documented from the US-current Series 4 generation.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
—
Output (max)
85 MBH
AFUE
84 %

The CGa-4 is the mid-size CGa Series 4 model of the cast iron line discontinued in Canada in 2023: 100 MBH CSA input, 85 MBH DOE heating capacity and a 73 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
—
Output (max)
113 MBH
AFUE
84 %

The CGa-5 is the first of the large-cabinet CGa Series 4 sizes, from the cast iron line discontinued in Canada in 2023: 133 MBH CSA input, 113 MBH DOE heating capacity and a 98 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
—
Output (max)
141 MBH
AFUE
84 %

The CGa-6 continues the large CGa Series 4 sizes of the cast iron line discontinued in Canada in 2023: 166 MBH CSA input, 141 MBH DOE heating capacity and a 122 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
—
Output (max)
170 MBH
AFUE
84 %

The CGa-7 is the second-largest CGa Series 4 size of the cast iron line discontinued in Canada in 2023: 200 MBH CSA input, 170 MBH DOE heating capacity and a 147 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
—
Output (max)
198 MBH
AFUE
84 %

The CGa-8 tops the CGa Series 4 range at 233 MBH CSA input with 198 MBH of DOE heating capacity, an 84% AFUE rating and a 7" vent — the largest of the cast iron line Canada discontinued in 2023.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Weil-McLain CGa-25 and Weil-McLain CGa-3 and Weil-McLain CGa-4 and Weil-McLain CGa-5 and Weil-McLain CGa-6 and Weil-McLain CGa-7 and Weil-McLain CGa-8
SpecificationWeil-McLain CGa-25Weil-McLain CGa-3Weil-McLain CGa-4Weil-McLain CGa-5Weil-McLain CGa-6Weil-McLain CGa-7Weil-McLain CGa-8
input-min———————
Input, maximum38 MBH67 MBH100 MBH133 MBH166 MBH200 MBH233 MBH
DOE heating capacity32 MBH56 MBH85 MBH113 MBH141 MBH170 MBH198 MBH
Efficiency (AFUE)84 %84 %84 %84 %84 %84 %84 %
turndown———————
vent-max-3———————
vent-max-2———————
weight———————

Read the full comparison: Weil-McLain CGa-25 vs CGa-3 →

Read the full comparison: Weil-McLain CGa-3 vs CGa-4 →

Read the full comparison: Weil-McLain CGa-4 vs CGa-5 →

Read the full comparison: Weil-McLain CGa-5 vs CGa-6 →

Error codes and alerts

CGa (cast iron) alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the CGa still available in Canada?

No, not as a new boiler. Weil-McLain Canada's April 2023 news release set a June 30, 2023 production cut-off for the CGa under federal efficiency standards, with remaining inventory sold only while supplies lasted.

Can I still get parts for a CGa in Canada?

Weil-McLain Canada's phase-out notice states parts will be available for at least 20+ years from the 2023 cut-off, and contractors were allowed to continue purchasing and installing CGa boilers after June 30, 2023 while inventory lasted.

Why does the US CGa look different from the Canadian one?

Canada's CGa data reflects the Series 3 generation (52-245 MBH inputs), frozen at the 2023 cut-off, while the US sells the CGa Series 4 (38-233 MBH) documented by manual 550-100-223/0425. Match all references to the generation on the rating plate.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate