Comparison

A. O. Smith Burkay HW-420 vs HW-670

Verdict in brief

The Burkay HW-420 and HW-670 are mid-range and top-of-line sizes: 420,000 versus 660,000 BTU/h natural-gas input (670,000 on propane for the HW-670), 336,000 versus 536,000 BTU/h output, and 1-1/2" versus 2" water connections. Both are current, 160 psi ASME-tested copper boilers; the HW-670 also steps the draft diverter outlet to 12".

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of A. O. Smith Burkay HW-420 and A. O. Smith Burkay HW-670
SpecificationA. O. Smith Burkay HW-420A. O. Smith Burkay HW-670
Input rating420,000 BTU/h natural and propane660,000 BTU/h natural / 670,000 BTU/h propane
Output rating336,000 BTU/h536,000 BTU/h
Water inlet / outlet1-1/2" NPT inlet / 1-1/2" NPT outlet2" NPT inlet / 2" NPT outlet
Gas inlet1" NPT1" NPT
Draft diverter outlet diameter10 in12 in
Approximate shipping weight301 lb381 lb
Recovery capacity (as printed)2,036 GPH at 20 °F rise (natural gas)3,200 GPH at 20 °F rise (natural gas) / 3,248 GPH (propane)

What actually separates them

The HW-420 and HW-670 are both current Conservationist Burkay commercial copper hot water boilers per spec sheet AOSDG25600. The HW-420 prints 420,000 BTU/h input and 336,000 BTU/h output. The HW-670 is printed as two rows — 660,000 BTU/h input on natural gas and 670,000 BTU/h on propane — with 528,000 BTU/h output natural and 536,000 BTU/h propane. It is the top of the line and the number the product page uses in its 'inputs up to 670,000 Btu' headline.

Connections scale with the size: 1-1/2" NPT water inlet and outlet and a 1" gas inlet on the HW-420, moving to 2" water and 1" gas on the HW-670, with the draft diverter outlet growing from 10" to 12". Recovery at 20 °F rise is 2,036 GPH for the HW-420 against 3,200 GPH natural / 3,248 GPH propane for the HW-670.

The two share the same construction and safety envelope: copper fin-tube heat exchanger and copper coil combustion chamber, all non-ferrous waterways, ASME 160 psi certification with a 125 psi relief valve, 120 V 60 Hz and a maximum 14" WC inlet gas pressure. No efficiency percentage is printed for either model. Choose on the calculated hot-water load and the near-boiler piping the connection sizes imply.

CurrentCanadian status unknown
Input
—
Output (max)
336,000 BTU/h
AFUE
—

The A. O. Smith Burkay HW-420 is a commercial gas-fired copper hot water boiler rated 420,000 BTU/h input and 336,000 BTU/h output, with 1-1/2" NPT water connections and a 1" NPT gas connection.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
536,000 BTU/h
AFUE
—

The A. O. Smith Burkay HW-670 is a commercial gas-fired copper hot water boiler rated 660,000 BTU/h input (670,000 BTU/h on propane) and 536,000 BTU/h output, with 2" NPT water connections and a 1" NPT gas connection.

Natural gasPropaneHeating-only

Frequently asked questions

What is the largest Burkay HW boiler?

The HW-670, printed at 660,000 BTU/h input natural gas and 670,000 BTU/h propane with 528,000 / 536,000 BTU/h output — the top of the current line.

Why does the HW-670 have two input ratings?

The spec sheet prints a natural-gas row (660,000 BTU/h) and a propane row (670,000 BTU/h) because the input differs slightly by fuel. Both rows are official.

What water connections does the HW-670 use?

Table 1 of AOSDG25600 prints 2" NPT water inlet and outlet connections and a 1" NPT gas inlet for the HW-670.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.