A. O. Smith Burkay HW-300 and A. O. Smith Burkay HW-399 are two non-condensing boilers from the A. O. Smith Conservationist Burkay (hot-water boilers) line. The A. O. Smith Burkay HW-300 is rated 300,000 BTU/h natural and propane input, and the A. O. Smith Burkay HW-399 is rated 399,000 BTU/h natural and propane input. A. O. Smith Burkay HW-399 lists 99,000 more input than A. O. Smith Burkay HW-300 (399,000 against 300,000). A. O. Smith Burkay HW-399 lists 51 lb more shipping weight than A. O. Smith Burkay HW-300 (301 lb against 250 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of A. O. Smith Burkay HW-300 and A. O. Smith Burkay HW-399
SpecificationA. O. Smith Burkay HW-300A. O. Smith Burkay HW-399
Input rating300,000 BTU/h natural and propane399,000 BTU/h natural and propane
Approximate shipping weight250 lb301 lb
Water inlet / outlet1-1/4" NPT inlet / 1-1/4" NPT outlet1-1/2" NPT inlet / 1-1/2" NPT outlet
Gas inlet3/4" NPT3/4" NPT
FuelNatural gas or propane (LP)Natural gas or propane (LP)
Draft diverter outlet diameter8 in10 in
Recovery capacity (as printed)1,455 GPH at 20 °F rise (natural gas)1,935 GPH at 20 °F rise (natural gas)
Working pressure160 psi, ASME tested and certified160 psi, ASME tested and certified

What actually separates them

Published ratings: the A. O. Smith Burkay HW-300 is rated 300,000 BTU/h natural and propane input; the A. O. Smith Burkay HW-399 is rated 399,000 BTU/h natural and propane input. A. O. Smith Burkay HW-399 lists 99,000 more input than A. O. Smith Burkay HW-300 (399,000 against 300,000).

A. O. Smith Burkay HW-399 lists 51 lb more shipping weight than A. O. Smith Burkay HW-300 (301 lb against 250 lb). The water connections differs: the A. O. Smith Burkay HW-300 lists 1-1/4" NPT inlet / 1-1/4" NPT outlet, while the A. O. Smith Burkay HW-399 lists 1-1/2" NPT inlet / 1-1/2" NPT outlet. The draft diverter outlet diameter differs: the A. O. Smith Burkay HW-300 lists 8 in, while the A. O. Smith Burkay HW-399 lists 10 in. The recovery capacity differs: the A. O. Smith Burkay HW-300 lists 1,455 GPH at 20 °F rise (natural gas), while the A. O. Smith Burkay HW-399 lists 1,935 GPH at 20 °F rise (natural gas).

Both records print the same gas connection (3/4" NPT), fuel (Natural gas or propane (LP)) and working pressure (160 psi, ASME tested and certified), per the cited sources.

CurrentCanadian status unknown
Input
—
Output (max)
Not present in the AOSDG25600 PDF text layer
AFUE
—

The A. O. Smith Burkay HW-300 is a commercial gas-fired copper hot water boiler rated 300,000 BTU/h input, with 1-1/4" NPT water connections and a 3/4" NPT gas connection.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
319,200 BTU/h
AFUE
—

The A. O. Smith Burkay HW-399 is a commercial gas-fired copper hot water boiler rated 399,000 BTU/h input and 319,200 BTU/h output, with 1-1/2" NPT water connections and a 3/4" NPT gas connection.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The A. O. Smith Burkay HW-399 lists 399,000 BTU/h natural and propane, against 300,000 BTU/h natural and propane on the A. O. Smith Burkay HW-300, per the cited documentation.

How much heavier is the A. O. Smith Burkay HW-399?

It ships at 301 lb against 250 lb for the A. O. Smith Burkay HW-300, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate