Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

AERCO Benchmark 5000 vs Benchmark 6000

Verdict in brief

The BMK 5000 and BMK 6000 share the same 35" × 89.3" × 79.8" cabinet, 400 MBH minimum input, 3,000 lb dry / 3,800 lb shipping weight and 6" water connection; the 6000 adds 1,000 MBH of maximum input and a deeper 15:1 turndown versus the 5000's 12:1, while printing 94.5% thermal efficiency against 94.8%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of AERCO Benchmark 5000 and AERCO Benchmark 6000
SpecificationAERCO Benchmark 5000AERCO Benchmark 6000
Min. input400 MBH400 MBH
Max. input5,000 MBH6,000 MBH
Max. output4,800 MBH5,760 MBH
Thermal efficiency (80–180°F)94.8 %94.5 %
Efficiency range87–98 %87–98 %
Turndown ratio12:1 (8%)15:1 (7%)
Gas connection (NPT)2" / 3"2" / 3"
Water connection (flanged)6"6"
Weight, dry3,000 lb3,000 lb
Shipping weight3,800 lb3,800 lb
Width (A)35 in35 in
Depth (B)89.3 in89.3 in
Height (C)79.8 in79.8 in

What actually separates them

These are the two largest standard Benchmark rows. AERCO prints 4350–4800 MBH output for the 5000 and 5220–5760 MBH for the 6000, on the same 35" wide × 89.3" deep × 79.8" high frame and the same 3,000 lb dry weight. The 5000/6000 gas connection is printed as 2" / 3" and water as 6" flanged for both.

Turndown is the interesting difference: the 6000 prints 15:1 (7%) while the 5000 prints 12:1 (8%) — the shallowest turndown in the Benchmark table. In plants with wide load swings the 6000's deeper modulation can matter more than its extra capacity.

Efficiency is effectively level: 94.8% thermal efficiency for the 5000 and 94.5% for the 6000 at 80º–180ºF. The TDS also prints a separate BMK 5000N low-gas-pressure variant (250–4990 MBH input, 20:1 (7%)) that Boilers.ca documents in a note rather than as a separate model.

CurrentCanadian status unknown
Input
400–5000 MBH
Output (max)
4,800 MBH
AFUE
—

The AERCO Benchmark 5000 (BMK 5000) is a condensing gas-fired firetube commercial boiler rated 5000 MBH maximum input and a 4350–4800 MBH output range in AERCO's published ratings table, at 94.8% thermal efficiency (87%–98% range), with 12:1 (8%) turndown and a 3000 lb dry weight.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
400–6000 MBH
Output (max)
5,760 MBH
AFUE
—

The AERCO Benchmark 6000 (BMK 6000) is a condensing gas-fired firetube commercial boiler rated 6000 MBH maximum input and a 5220–5760 MBH output range in AERCO's published ratings table, at 94.5% thermal efficiency (87%–98% range), with 15:1 (7%) turndown and a 3000 lb dry weight.

Natural gasPropaneHeating-only

Frequently asked questions

Which has the deeper turndown?

The BMK 6000 at 15:1 (7%) versus 12:1 (8%) for the BMK 5000, per AERCO's TDS.

Are the dimensions identical?

Yes — both print 35" wide × 89.3" deep × 79.8" high with the same 3,000 lb dry and 3,800 lb shipping weights.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate