Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

American Standard AGBWF130A94AV vs AGBWF173A95AV

Verdict in brief

The AGBWF130A94AV and AGBWF173A95AV share the identical 33.5 x 19.7 x 24.2 in cabinet, yet the 173 adds 43,000 BTU/hr of input and 34,000 BTU/hr of heat capacity for 61 lb of extra shipping weight. Both print a natural draft vent arrangement and efficiencies within 0.1 points (83.5% against 83.4%), so the extra ceiling is the only reason to move up.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of American Standard AGBWF130A94AV (natural draft gas boiler) and American Standard AGBWF173A95AV (natural draft gas boiler)
SpecificationAmerican Standard AGBWF130A94AV (natural draft gas boiler)American Standard AGBWF173A95AV (natural draft gas boiler)
Vent style (as printed)Natural draftNatural draft
Input (as printed)130,000 BTU/hr173,000 BTU/hr
Heat capacity (as printed)111,000 BTU/hr145,000 BTU/hr
AFUE (as printed)83.5 %83.4 %
Height (as printed)33.5 in33.5 in
Width (as printed)19.7 in19.7 in
Depth (as printed)24.2 in24.2 in
Shipping weight (as printed)345 lb406 lb

What actually separates them

These are the middle two sizes of the four-model natural draft family, and the archived official page prints a full rating row for each. The AGBWF130A94AV is rated 83.5% AFUE, 130,000 BTU/hr input and 111,000 BTU/hr heat capacity; the AGBWF173A95AV is rated 83.4%, 173,000 BTU/hr and 145,000 BTU/hr.

The physical package is the same 33.5 x 19.7 x 24.2 in envelope, so the 173's extra 43,000 BTU/hr of input comes from a larger heat exchanger inside the same footprint - the shipping weight rises from 345 to 406 lb. Both list the same cast iron construction, stainless steel tubular burner, electronic ignition and electric vent damper.

In practice the decision comes down to the design-day load: a home that fits inside the 130's 111,000 BTU/hr capacity gains nothing from the larger model, while a load that exceeds it cannot be met by the smaller unit. Neither model condenses, so both sit in the same 83% efficiency band and the operating-cost difference tracks the load match rather than the AFUE figure.

Frequently asked questions

Do the AGBWF130A94AV and AGBWF173A95AV share a cabinet?

Yes - both are 33.5 in high, 19.7 in wide and 24.2 in deep; the 173 ships at 406 lb against 345 lb.

How much more capacity does the 173 add?

43,000 BTU/hr of input and 34,000 BTU/hr of heat capacity: 173,000/145,000 against 130,000/111,000 BTU/hr.

Which one is more efficient?

The AGBWF130A94AV prints 83.5% AFUE and the AGBWF173A95AV 83.4%, both from the archived official rating table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate