American Standard AGRWF130A94A0 vs AGBWF130A94AV

Verdict in brief

Both models fire 130,000 BTU/hr in the same 33.5 x 19.7 x 24.2 in cabinet, but the direct vent AGRWF130A94A0 is rated 0.8 points higher at 84.3% AFUE and delivers 110,000 BTU/hr of heat capacity against the natural draft AGBWF130A94AV's 111,000 BTU/hr at 83.5%. The direct vent model ships 15 lb heavier (360 against 345 lb) and is the line's efficiency leader.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of American Standard AGRWF130A94A0 (direct vent gas boiler) and American Standard AGBWF130A94AV (natural draft gas boiler)
SpecificationAmerican Standard AGRWF130A94A0 (direct vent gas boiler)American Standard AGBWF130A94AV (natural draft gas boiler)
Vent style (as printed)Direct ventNatural draft
Input (as printed)130,000 BTU/hr130,000 BTU/hr
Heat capacity (as printed)110,000 BTU/hr111,000 BTU/hr
AFUE (as printed)84.3 %83.5 %
Height (as printed)33.5 in33.5 in
Width (as printed)19.7 in19.7 in
Depth (as printed)24.2 in24.2 in
Shipping weight (as printed)360 lb345 lb

What actually separates them

American Standard's archived official gas page splits the line into a direct vent group and a natural draft group, and this pair is the direct comparison at the same firing rate. The AGRWF130A94A0 is the only direct vent model listed, rated 84.3% AFUE with 130,000 BTU/hr input and 110,000 BTU/hr heat capacity. The AGBWF130A94AV is the matching natural draft size at 83.5% AFUE, 130,000 BTU/hr input and 111,000 BTU/hr heat capacity.

The cabinets are identical in height, width and depth (33.5 x 19.7 x 24.2 in), and the direct vent model ships at 360 lb against 345 lb. The practical difference is the vent route: the direct vent model uses its own sealed combustion-air and exhaust arrangement rather than a chimney, while the natural draft model relies on a chimney and lists a standard electric vent damper.

The efficiency gap is 0.8 points in the direct vent model's favour - the largest spread in the gas line - which matters in homes where a chimney route is difficult or where the boiler shares a flue. Where a suitable chimney exists, the natural draft model's marginally higher printed heat capacity (111,000 against 110,000 BTU/hr) is not enough to offset the direct vent model's AFUE advantage.

Frequently asked questions

Which American Standard gas boiler has the highest AFUE?

The direct vent AGRWF130A94A0 at 84.3%, the best figure printed on the archived official gas page; the natural draft models range from 83.3% to 83.6%.

Do the two 130,000 BTU/hr models share a cabinet?

Yes - both are 33.5 in high, 19.7 in wide and 24.2 in deep; the direct vent model ships at 360 lb against 345 lb.

Which one avoids a chimney?

The direct vent AGRWF130A94A0. The natural draft models vent through a chimney and list a standard electric vent damper.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.