Crown Aruba 4 AWR210E vs AWR245E

Verdict in brief

The AWR210E and AWR245E are the seventh and eighth legacy Aruba 4 sizes, both NON-condensing Category I cast-iron boilers at 83.4% AFUE: the 245E fires a fixed 245 MBH against 210 MBH (DOE 205 vs 175 MBH, net AHRI 178 vs 152 MBH) over 8 sections, growing dimension A from 24-5/8" to 27-5/8" and the flue connector from 7" to 8".

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Crown Aruba 4 AWR210E and Crown Aruba 4 AWR245E
SpecificationCrown Aruba 4 AWR210ECrown Aruba 4 AWR245E
Input210 MBH245 MBH
DOE heating capacity175 MBH205 MBH
Net AHRI water rating152 MBH178 MBH
Efficiency (AFUE)83.4 %83.4 %
Cast-iron sections78
Dimensions (A × B)24-5/8" × 33-1/2"27-5/8" × 33-1/2"
VentingCategory I natural draft — draft hood built into the boiler; lined masonry or listed metal chimneyCategory I natural draft — draft hood built into the boiler; lined masonry or listed metal chimney
Supply/return tappings1-1/4"1-1/4"
Ignition and controlsHoneywell S9361A interrupted ignition with vent damperHoneywell S9361A interrupted ignition with vent damper
FuelNatural gas or propaneNatural gas or propane
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both are cast-iron, NON-condensing, Category I natural-draft Aruba 4 boilers with built-in draft hoods, mandatory vent dampers, 1-1/4" side-relocatable tappings and Honeywell S9361A interrupted ignition — both share the 33-1/2" dimension B jacket; the 245E carries the alcove front-clearance rating of the AWR245-280 group while the 210E belongs to the AWR038-210 group's 6" front-clearance rating.

The AWR245E raises the fixed input from 210 to 245 MBH across 8 cast-iron sections (7 on the 210E), printing 205 MBH DOE heating capacity and a 178 MBH net AHRI water rating against 175 and 152 MBH, at the same 83.4% AFUE.

The flue connector (C) steps from 7" on the 210E to 8" on the 245E, and dimension A grows from 24-5/8" to 27-5/8". Above 2,000 ft both need different main burner orifices; NG/LP suffix codes complete the model numbers (AWR210EN/EL, AWR245EN/EL).

Crown Boiler Co.

Crown Aruba 4 AWR210E

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
83.4 %

The Crown Aruba 4 AWR210E fires a fixed 210 MBH for 175 MBH DOE heating capacity and a 152 MBH net AHRI rating at 83.4% AFUE across 7 cast-iron sections, with a 7" flue connector and the taller 33-1/2" dimension B.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR245E

DiscontinuedCanadian status unknown
Input
Output (max)
AFUE
83.4 %

The Crown Aruba 4 AWR245E fires a fixed 245 MBH for 205 MBH DOE heating capacity and a 178 MBH net AHRI rating at 83.4% AFUE across 8 cast-iron sections, with the 8" flue connector and alcove clearance group.

Natural gasPropaneHeating-only

Frequently asked questions

What does the AWR245E add over the AWR210E?

35 MBH of fixed input (245 vs 210), 30 MBH of DOE capacity (205 vs 175), 26 MBH of net AHRI (178 vs 152), one more section and an 8" flue connector against 7".

Are these the largest Aruba 4 sizes?

The AWR245E is the second-largest — the AWR280E (280 MBH, 9 sections) tops the line.

Do the large AWR sizes need special clearances?

The manual's locating section groups clearances by size: the AWR038E–210E boilers allow a 6" front clearance, while the AWR245E/280E carry an alcove front-clearance rating.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate