Buderus G615/570 vs G615/1200

Verdict in brief

The discontinued G615/570 and G615/1200 are the largest Buderus cast-iron boiler blocks in the archived commercial line, fired by field-supplied oil, gas or combination burners. The /570 uses 9 sections with 1,951 MBH gross output, 2,309 MBH gas input and 5,523 lb net weight; the /1200 uses 16 sections with 3,982 MBH gross, 4,835 MBH gas input and 9,143 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Buderus G615/570 and Buderus G615/1200
SpecificationBuderus G615/570Buderus G615/1200
Number of boiler sections916
Gross output1,951 MBH3,982 MBH
Net AHRI rating, water (gas and oil)1,697 MBH3,463 MBH
Input rating, gas2,309 MBH4,835 MBH
Input rating, oil9 gph16 gph
Weight, net5,523 lb9,143 lb
Boiler water content148.25 US gal259.25 US gal

What actually separates them

Both sizes share the Logano G615 design: Buderus cast-iron sections with Thermostream return-water mixing, 248 °F maximum permissible supply temperature, 87 psi maximum operating pressure and forced-draft burner mounting. The technical table's gross-output values are printed in kW and MBH-equivalent numbers (570 to 1200).

Ratings scale: gross output 1,951 to 3,982 MBH, net AHRI water ratings 1,697 to 3,463 MBH, gas input 2,309 to 4,835 MBH and oil input 9 to 16 GPH across the eight sizes. Sections run 9 to 16.

Physical rows: net weight 5,523 to 9,143 lb and boiler water content 148.25 to 259.25 US gal. The G615 is discontinued with installation/service and operating manuals in Bosch's US commercial-discontinued archive. Note the official table's flue-gas mass-flow rows are mislabeled °F while carrying lb/s values; Boilers.ca uses only the unambiguous rows.

Bosch Thermotechnology

Buderus G615/570

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/570 is a discontinued commercial cast-iron boiler block with 9 sections, 1,951 MBH gross output and 1,697 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus G615/1200

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Buderus G615/1200 is a discontinued commercial cast-iron boiler block with 16 sections, 3,982 MBH gross output and 3,463 MBH net AHRI rating for oil or gas firing.

Natural gasPropaneHeating-only

Frequently asked questions

What is the largest G615 size?

The G615/1200 with 16 sections, 3,982 MBH gross output, 4,835 MBH gas input and 9,143 lb net weight.

Do G615 boilers include controls?

No - they are boiler blocks with external controls (aquastat, Logamatic 4000 or BMS) and a field-supplied burner from Bosch's approved list.

Why are the G615 flue-gas rows unusual?

The official technical table labels its flue-gas mass-flow rows with °F while the values are in lb/s and kg/s. Boilers.ca treats those rows as unusable and records only the output, input, weight and water rows.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate