Buderus GC144 II 18/3 vs 32/5

Verdict in brief

The discontinued GC144 II 18/3 and 32/5 share the atmospheric cast-iron design, 220 °F maximum boiler temperature and 58 psi maximum operating pressure. The 18/3 fires 74,000 BTU/hr at 228 lb dry with a 5" vent; the 32/5 fires 132,500 BTU/hr at 349.5 lb with a 6" vent, and the manual adds altitude input tables to 8,500 ft.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Buderus GC144 II 18/3 and Buderus GC144 II 32/5
SpecificationBuderus GC144 II 18/3Buderus GC144 II 32/5
Boiler input74 MBH132.5 MBH
Dry weight228 lb349.5 lb
Water volume2.4 US gal3.4 US gal
Vent connection5"6"
Maximum boiler temperature220 °F220 °F
Maximum operating pressure58 psi58 psi

What actually separates them

The GC 144 II installation manual describes an atmospheric gas boiler with a cast-iron heat exchanger for single or multiple-occupancy buildings. Both sizes share 220 °F maximum boiler temperature, 58 psi maximum operating pressure and the NG/LP orifice and manifold-pressure tables.

Ratings scale: 18/3 at 74,000 BTU/hr input and 228 lb dry; 25/4 at 103,000 BTU/hr and 287 lb; 32/5 at 132,500 BTU/hr and 349.5 lb. Water volumes are 2.4, 2.9 and 3.4 US gallons, and vent connections are 5", 5" and 6".

The manual's chapter 16 prints burner input at altitude: 74/103/133 MBTU/hr at sea level falling to 63/88/113 MBTU/hr at 8,500 ft, with the boiler not approved above 8,500 ft. The GC 144 II is on Bosch's US 'Discontinued Boilers' page with installation, operating, spare-parts and propane-conversion documents.

Bosch Thermotechnology

Buderus GC144 II 18/3

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Buderus GC144 II 18/3 is a discontinued atmospheric cast-iron gas boiler rated 74,000 BTU/hr input with a 228 lb dry weight and 2.4 US gal water volume.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Buderus GC144 II 32/5

DiscontinuedHistorically in Canada
Input
—
Output (max)
—
AFUE
—

The Buderus GC144 II 32/5 is a discontinued atmospheric cast-iron gas boiler rated 132,500 BTU/hr input with a 349.5 lb dry weight and 3.4 US gal water volume.

Natural gasPropaneHeating-only

Frequently asked questions

How much does altitude reduce GC144 II input?

The manual's table shows the 18/3 falling from 74 to 63 MBTU/hr, the 25/4 from 103 to 88 and the 32/5 from 133 to 113 between sea level and 8,500 ft.

Is the GC144 II approved above 8,500 ft?

No. The manual states the GC 144 II is not approved above 8,500 ft and directs you to contact Buderus for another product option.

Does the GC144 II have a code display?

No - it uses a mechanical ignition module and adjustable temperature controller, so the manual set has no discrete fault-code table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate