Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Bosch Greenstar ZBR 35-3A vs ZWB 35-3A

Verdict in brief

The Bosch Greenstar ZBR 35-3A and Bosch Greenstar ZWB 35-3A are both condensing boilers in the Bosch Thermotechnology Greenstar Wall (ZBR/ZWB) line. Published ratings: Bosch Greenstar ZBR 35-3A at 36–131.9 MBH input and 122.8 MBH output; Bosch Greenstar ZWB 35-3A at 36–131.9 MBH input and 122.8 MBH output. Both list the same published input of 131.9 MBH. Bosch Greenstar ZWB 35-3A lists 6.6 lb more shipping weight than Bosch Greenstar ZBR 35-3A (110.2 lb against 103.6 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Bosch Greenstar ZBR 35-3A and Bosch Greenstar ZWB 35-3A
SpecificationBosch Greenstar ZBR 35-3ABosch Greenstar ZWB 35-3A
Input rate, minimum36 MBH36 MBH
Input rate, maximum131.9 MBH131.9 MBH
Output rate, maximum (104/86 °F)122.8 MBH122.8 MBH
Weight (without packaging)103.6 lb110.2 lb
Dimensions (W x H x D)17-21/64" × 33-15/32" × 13-57/64" (440 × 850 × 353 mm)17-21/64" × 33-15/32" × 13-57/64" (440 × 850 × 353 mm)
Venting2" NG only; 3" or 3"/5" (80/125 mm) concentric for LPG2" NG only; 3" or 3"/5" (80/125 mm) concentric for LPG
FuelNatural gas or propaneNatural gas or propane
Sound pressure level≤ 44 dB(A)≤ 44 dB(A)
Maximum supply temperature187 °F187 °F
Maximum permissible operating pressure (PMS), heating30 psi30 psi
Permissible inlet gas pressureNG 3.5–10.5 in. W.C.; LPG 8–13 in. W.C.NG 3.5–10.5 in. W.C.; LPG 8–13 in. W.C.

What actually separates them

Published ratings: the Bosch Greenstar ZBR 35-3A is rated 36–131.9 MBH input and 122.8 MBH output; the Bosch Greenstar ZWB 35-3A is rated 36–131.9 MBH input and 122.8 MBH output. Both list the same published input of 131.9 MBH.

Bosch Greenstar ZWB 35-3A lists 6.6 lb more shipping weight than Bosch Greenstar ZBR 35-3A (110.2 lb against 103.6 lb).

Both records print the same input (36 MBH), input (131.9 MBH), output (122.8 MBH) and dimensions (17-21/64" × 33-15/32" × 13-57/64" (440 × 850 × 353 mm)), per the cited sources.

Bosch Thermotechnology

Bosch Greenstar ZBR 35-3A

CurrentSold in Canada
Input
36–131.9 MBH
Output (max)
122.8 MBH
AFUE
—

The Greenstar ZBR 35-3A is the 132 MBH-class wall-hung heating-only Greenstar: 36,000 to 131,900 BTU/hr natural-gas input in the standard 103.6 lb wall cabinet, with the shorter vent runs Bosch allows for the 35/42 size class.

Natural gasPropaneHeating-only

Bosch Thermotechnology

Bosch Greenstar ZWB 35-3A

CurrentSold in Canada
Input
36–131.9 MBH
Output (max)
122.8 MBH
AFUE
—

The Greenstar ZWB 35-3A is the mid-size wall-hung Greenstar combi — 36,000 to 131,900 BTU/hr natural-gas heating input with DHW output to 118,700 BTU/hr at a 140 °F outlet and 3.17 GPM maximum DHW flow — documented in the Greenstar Wall I&O manual because the Combi 100P/151P manual does not cover the 35-3A size.

Natural gasPropaneCombi

Frequently asked questions

Do the two models share the same input?

Yes — both list 131.9 MBH in the cited documentation.

How much heavier is the Bosch Greenstar ZWB 35-3A?

It ships at 110.2 lb against 103.6 lb for the Bosch Greenstar ZBR 35-3A, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate