Verdict in brief

The DynaFlame DFH 0500 and DFH 0750 are the two smallest non-condensing hydronic-heating sizes in Camus' stainless watertube line: 500 against 750 MBTU/hr input, 425 against 638 MBTU/hr output, with the same 85% thermal efficiency, 3:1 turndown and 439 stainless heat exchanger.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Camus DynaFlame DFH 0500 (Non-Condensing Heating) and Camus DynaFlame DFH 0750 (Non-Condensing Heating)
SpecificationCamus DynaFlame DFH 0500 (Non-Condensing Heating)Camus DynaFlame DFH 0750 (Non-Condensing Heating)
Input, maximum500 MBTU/hr750 MBTU/hr
Output, maximum425 MBTU/hr638 MBTU/hr
Thermal efficiency85 %85 %
Turndown ratio3:13:1
Shipping weight520 lb600 lb
VentingCat. I 8" · Cat. III up to 50 ft 4" · Cat. III up to 100 ft 6" · outdoor 4"Cat. I 10" · Cat. III up to 50 ft 6" · Cat. III up to 100 ft 8" · outdoor 6"
CertificationCSA International design certified; ANSI Z21.13 / CSA 4.9CSA International design certified; ANSI Z21.13 / CSA 4.9

What actually separates them

Both models come from the same official spec sheet (99-0143 Rev 01) and share the non-condensing DynaFlame platform: a 439 stainless-steel six-pass vertical cylindrical watertube heat exchanger rated 160 psig, up to 85% thermal efficiency, a 3:1 turndown ratio with a minimum 35% firing rate, and Category I/III venting. They also share the same control family, CSA certification (ANSI Z21.13 / CSA 4.9) and natural-gas/propane/dual-fuel gas-train description.

The difference is size and the equipment that scales with it. The DFH 0500 prints 500 MBTU/hr input / 425 MBTU/hr output and a 520 lb shipping weight; the DFH 0750 prints 750 MBTU/hr input / 638 MBTU/hr output and 600 lb. The printed vent-diameter table also steps up: the 0500 allows Cat. I 8" (Cat. III 4" up to 50 ft / 6" up to 100 ft), while the 0750 allows Cat. I 10" (Cat. III 6" / 8").

The choice is a load calculation: a plant whose design load sits near 425 MBTU/hr of output is served by the 0500, while a load approaching or crossing 500 MBTU/hr points to the 0750. Both are non-condensing, so return-water temperature protection matters on either; that design work belongs with a licensed contractor.

Frequently asked questions

Are the DFH 0500 and DFH 0750 condensing?

No. Both are non-condensing DynaFlame models: the official spec sheet prints up to 85% thermal efficiency and Category I/III venting.

What is the output difference?

The DFH 0500 prints 425 MBTU/hr output from 500 MBTU/hr input; the DFH 0750 prints 638 MBTU/hr output from 750 MBTU/hr input, per spec sheet 99-0143 Rev 01.

Do they share a heat exchanger design?

Yes. Both use the DynaFlame 439 stainless-steel six-pass vertical cylindrical watertube exchanger rated 160 psig; the physical size and weights scale with the model.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate