Slant/Fin CHS-285 vs CHS-340

Verdict in brief

The CHS-285 and CHS-340 are adjacent sizes in Slant/Fin's CHS high-efficiency fire-tube condensing gas boiler line. The CHS-340 fires up to 340 MBH against the CHS-285's 285 MBH, printing 324 MBH gross heating capacity (263) and a 282 MBH AHRI net rating (229); 95% (AFUE) against 95.4% (thermal efficiency). water connections step from 1¼" NPT to 1½" NPT, both use ¾" NPT gas and the vent/air connection steps from 3" to 4". Turndown is printed as 10:1 on the CHS-285 and 10:1 on the CHS-340.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Slant/Fin CHS-285 and Slant/Fin CHS-340
SpecificationSlant/Fin CHS-285Slant/Fin CHS-340
Input, minimum28.5 MBH39.9 MBH
Input, maximum285 MBH340 MBH
Heating capacity263 MBH324 MBH
Net AHRI rating229 MBH282 MBH
AFUE95 %95.4 %
Water connections1¼" NPT1½" NPT
Gas connection¾" NPT¾" NPT
Vent / air connection3"4"

What actually separates them

Both models are CHS Series high-efficiency fire-tube condensing gas boilers held in Slant/Fin's active 'Boilers' library section, with direct spark ignition, a modulating burner, outdoor reset, DHW priority and lead-lag capability up to 8 boilers. Slant/Fin prints no 'current' or 'discontinued' sentence; section placement is the only official status wording.

The official submittal table prints 28.5–285 MBH input on the CHS-285, 263 MBH heating capacity and a 229 MBH AHRI net rating, against 39.9–340 MBH, 324 MBH gross heating capacity and 282 MBH on the CHS-340. Turndown is printed as 10:1 and 10:1 respectively.

Connections scale with the size: water connections step from 1¼" NPT to 1½" NPT, both use ¾" NPT gas and the vent/air connection steps from 3" to 4". The CHS hub also hosts the official 2018 recall documents (CPSC notice plus contractor and homeowner notifications) — owners should check whether their unit's date range is affected. A heat-loss calculation decides between the two sizes, and gas, venting and combustion work belongs with a licensed contractor.

Status unknownCanadian status unknown
Input
28.5–285 MBH
Output (max)
—
AFUE
95 %

The Slant/Fin CHS-285 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 28.5–285 MBH input, 263 MBH heating capacity, a 229 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
39.9–340 MBH
Output (max)
—
AFUE
95.4 %

The Slant/Fin CHS-340 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 39.9–340 MBH input, 324 MBH gross heating capacity, a 282 MBH AHRI net rating and 95.4% thermal efficiency. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only

Frequently asked questions

What does the CHS-340 add over the CHS-285?

340 MBH maximum input against 285 MBH, 324 MBH gross heating capacity against 263 MBH, and a 282 MBH AHRI net rating against 229 MBH, per the official CHS submittal sheet.

Are both boilers condensing?

Yes — every CHS is a high-efficiency fire-tube condensing gas boiler; the series prints 95.0% AFUE for CHS-85 through CHS-285 and 95.4% thermal efficiency for CHS-340/399.

Was the CHS recalled?

The official CHS hub hosts 2018 recall documents — a CPSC notice plus contractor and homeowner official notifications. Owners should open the current notices on slantfin.com and act on any that apply to their unit's date range.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.