Slant/Fin CHS-85 vs CHS-110

Verdict in brief

The CHS-85 and CHS-110 are adjacent sizes in Slant/Fin's CHS high-efficiency fire-tube condensing gas boiler line. The CHS-110 fires up to 108 MBH against the CHS-85's 85 MBH, printing 99 MBH heating capacity (78) and a 86 MBH AHRI net rating (68); both 95%. both use 1" NPT water connections, both use ½" NPT gas and both use 3" vent/air connections. Turndown is printed as 5:1 on the CHS-85 and 5:1 on the CHS-110.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Slant/Fin CHS-85 and Slant/Fin CHS-110
SpecificationSlant/Fin CHS-85Slant/Fin CHS-110
Input, minimum17 MBH21.6 MBH
Input, maximum85 MBH108 MBH
Heating capacity78 MBH99 MBH
Net AHRI rating68 MBH86 MBH
AFUE95 %95 %
Water connections1" NPT1" NPT
Gas connection½" NPT½" NPT
Vent / air connection3"3"

What actually separates them

Both models are CHS Series high-efficiency fire-tube condensing gas boilers held in Slant/Fin's active 'Boilers' library section, with direct spark ignition, a modulating burner, outdoor reset, DHW priority and lead-lag capability up to 8 boilers. Slant/Fin prints no 'current' or 'discontinued' sentence; section placement is the only official status wording.

The official submittal table prints 17–85 MBH input on the CHS-85 (LP 17.6–88), 78 MBH heating capacity and a 68 MBH AHRI net rating, against 21.6–108 MBH (LP 22.6–113), 99 MBH heating capacity and 86 MBH on the CHS-110. Turndown is printed as 5:1 and 5:1 respectively.

Connections scale with the size: both use 1" NPT water connections, both use ½" NPT gas and both use 3" vent/air connections. The CHS hub also hosts the official 2018 recall documents (CPSC notice plus contractor and homeowner notifications) — owners should check whether their unit's date range is affected. A heat-loss calculation decides between the two sizes, and gas, venting and combustion work belongs with a licensed contractor.

Status unknownCanadian status unknown
Input
17–85 MBH
Output (max)
—
AFUE
95 %

The Slant/Fin CHS-85 is the smallest size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 17–85 MBH input (NG; LP 17.6–88), 78 MBH heating capacity, a 68 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
21.6–108 MBH
Output (max)
—
AFUE
95 %

The Slant/Fin CHS-110 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 21.6–108 MBH input (NG; LP 22.6–113), 99 MBH heating capacity, a 86 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only

Frequently asked questions

What does the CHS-110 add over the CHS-85?

108 MBH maximum input against 85 MBH, 99 MBH heating capacity against 78 MBH, and a 86 MBH AHRI net rating against 68 MBH, per the official CHS submittal sheet.

Are both boilers condensing?

Yes — every CHS is a high-efficiency fire-tube condensing gas boiler; the series prints 95.0% AFUE for CHS-85 through CHS-285 and 95.4% thermal efficiency for CHS-340/399.

Was the CHS recalled?

The official CHS hub hosts 2018 recall documents — a CPSC notice plus contractor and homeowner official notifications. Owners should open the current notices on slantfin.com and act on any that apply to their unit's date range.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.