Verdict in brief

The ClearFire-C 1500 adds 500,000 BTU/hr of input and 480,000 BTU/hr of output over the ClearFire-C 1000. The CFC 1500 steps the flue from 8 in to 10 in, the water connections from 2-1/2 in to 3 in and the water content from 90 to 113 gal while adding 500,000 BTU/hr of input.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Cleaver-Brooks ClearFire-C 1000 and Cleaver-Brooks ClearFire-C 1500
SpecificationCleaver-Brooks ClearFire-C 1000Cleaver-Brooks ClearFire-C 1500
Input (max)1,000,000 BTU/hr1,500,000 BTU/hr
Output at 104/86°F, 100% firing960,000 BTU/hr1,440,000 BTU/hr
Boiler horsepower28.743
Efficiency (page)99 %99 %
Water content90 gal113 gal
Shipping weight1,795 lb2,225 lb
Water supply / return2-1/2" 150# RF flanged3" 150# RF flanged
Flue gas connection8 in10 in

What actually separates them

The CFC 1000 carries 99% efficiency and the CFC 1500 99%. The ClearFire-C 1500 adds 500,000 BTU/hr of input and 480,000 BTU/hr of output over the ClearFire-C 1000. The CFC 1500 steps the flue from 8 in to 10 in, the water connections from 2-1/2 in to 3 in and the water content from 90 to 113 gal while adding 500,000 BTU/hr of input.

Water content moves from 90 gal to 113 gal, which changes the system volume and buffer behaviour. Shipping weight steps from 1,795 lb to 2,225 lb, so rigging and floor loading should be checked against the larger unit. Pressure rating: 125 on the smaller unit against 125 on the larger.

Both models are documented in the same official Cleaver-Brooks material, so the choice is a load and plant-layout decision: size to the calculated demand, then verify connections, venting and weight in the family document for the exact model.

Status unknownCanadian status unknown
Input
Output (max)
960,000 BTU/hr
AFUE

The Cleaver-Brooks ClearFire-C 1000 (Model CFC 1000) is a fully condensing hydronic boiler rated 1,000,000 BTU/hr input and 960,000 BTU/hr output at 104/86°F, with 28.7 BHP and 90 gal water content per the official CB-8278 Dimensions and Ratings.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
Output (max)
1,440,000 BTU/hr
AFUE

The Cleaver-Brooks ClearFire-C 1500 (Model CFC 1500) is a fully condensing hydronic boiler rated 1,500,000 BTU/hr input and 1,440,000 BTU/hr output at 104/86°F, with 43 BHP and 113 gal water content per the official CB-8278 Dimensions and Ratings.

Natural gasPropaneHeating-only

Frequently asked questions

What connections does the CFC 1500 use?

3 in 150# flanged water supply/return, a 1-1/2 in gas connection, a 10 in flue and 6 in or 8 in combustion air per CB-8278.

Does the fan motor change?

Yes — the CFC 1000 uses a 335 W fan at 4 A and the CFC 1500 a 750 W fan at 8.5 A, per CB-8278.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.