Cleaver-Brooks ClearFire-C 2500 vs ClearFire-C 3300

Verdict in brief

The ClearFire-C 3300 adds 800,000 BTU/hr of input and 768,000 BTU/hr of output over the ClearFire-C 2500. The CFC 3300 is the largest Model CFC: 3,300,000 BTU/hr input, 94.6 BHP, 209 gal water content and a 2 in gas connection, and it is the only size that moves to 208-240 V three-phase fan power.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Cleaver-Brooks ClearFire-C 2500 and Cleaver-Brooks ClearFire-C 3300
SpecificationCleaver-Brooks ClearFire-C 2500Cleaver-Brooks ClearFire-C 3300
Input (max)2,500,000 BTU/hr3,300,000 BTU/hr
Output at 104/86°F, 100% firing2,400,000 BTU/hr3,168,000 BTU/hr
Boiler horsepower71.794.6
Efficiency (page)99 %99 %
Water content126 gal209 gal
Shipping weight3,640 lb4,835 lb
Water supply / return5" 150# RF flanged5" 150# RF flanged
Flue gas connection12 in12 in

What actually separates them

The CFC 2500 carries 99% efficiency and the CFC 3300 99%. The ClearFire-C 3300 adds 800,000 BTU/hr of input and 768,000 BTU/hr of output over the ClearFire-C 2500. The CFC 3300 is the largest Model CFC: 3,300,000 BTU/hr input, 94.6 BHP, 209 gal water content and a 2 in gas connection, and it is the only size that moves to 208-240 V three-phase fan power.

Water content moves from 126 gal to 209 gal, which changes the system volume and buffer behaviour. Shipping weight steps from 3,640 lb to 4,835 lb, so rigging and floor loading should be checked against the larger unit. Pressure rating: 125 on the smaller unit against 125 on the larger.

Both models are documented in the same official Cleaver-Brooks material, so the choice is a load and plant-layout decision: size to the calculated demand, then verify connections, venting and weight in the family document for the exact model.

Status unknownCanadian status unknown
Input
Output (max)
2,400,000 BTU/hr
AFUE

The Cleaver-Brooks ClearFire-C 2500 (Model CFC 2500) is a fully condensing hydronic boiler rated 2,500,000 BTU/hr input and 2,400,000 BTU/hr output at 104/86°F, with 71.7 BHP and 126 gal water content per the official CB-8278 Dimensions and Ratings.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
Output (max)
3,168,000 BTU/hr
AFUE

The Cleaver-Brooks ClearFire-C 3300 (Model CFC 3300) is a fully condensing hydronic boiler rated 3,300,000 BTU/hr input and 3,168,000 BTU/hr output at 104/86°F, with 94.6 BHP and 209 gal water content per the official CB-8278 Dimensions and Ratings.

Natural gasPropaneHeating-only

Frequently asked questions

What is the largest ClearFire-C size?

The CFC 3300 at 3,300,000 BTU/hr input and 3,168,000 BTU/hr output at 104/86°F, per CB-8278.

Why does the CFC 3300 need three-phase power?

CB-8278 prints a 208-240/3/60 fan motor for the 3300 against 115/1/60 for the smaller sizes.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate