Cleaver-Brooks ClearFire-W CFW 400 vs ClearFire-W CFW 500

Verdict in brief

Both sizes sit on the same ClearFire-W platform. The CFW 400 and 500 both draw a 7 in w.c. minimum gas pressure, but water capacity more than doubles from 43 to 93 gal in the step.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Cleaver-Brooks ClearFire-W CFW 400 and Cleaver-Brooks ClearFire-W CFW 500
SpecificationCleaver-Brooks ClearFire-W CFW 400Cleaver-Brooks ClearFire-W CFW 500
Efficiency (manual)88 %88 %
Water content43 gal93 gal
Minimum gas pressure at gas train connection7 in w.c.7 in w.c.
MAWP125 psig125 psig

What actually separates them

The CFW 400 carries 88% efficiency and the CFW 500 88%. Both sizes sit on the same ClearFire-W platform. The CFW 400 and 500 both draw a 7 in w.c. minimum gas pressure, but water capacity more than doubles from 43 to 93 gal in the step.

Water content moves from 43 gal to 93 gal, which changes the system volume and buffer behaviour. Pressure rating: 125 on the smaller unit against 125 on the larger.

Both models are documented in the same official Cleaver-Brooks material, so the choice is a load and plant-layout decision: size to the calculated demand, then verify connections, venting and weight in the family document for the exact model.

Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 400 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 43 gal water capacity and a 7 in w.c. minimum gas pressure.

Natural gasHeating-only
Status unknownCanadian status unknown
Input
Output (max)
AFUE

The Cleaver-Brooks ClearFire-W CFW 500 is a compact vertically fired firetube hydronic boiler documented by the official Model CFW O&M manual (750-296), with 93 gal water capacity and a 7 in w.c. minimum gas pressure.

Natural gasHeating-only

Frequently asked questions

What data is printed for the CFW sizes?

The official Model CFW O&M manual prints water capacity (Table 4-1) and minimum/maximum gas pressures (Table 2-3); it does not print input/output ratings.

What is the CFW efficiency?

The manual states a nominal fuel-to-water efficiency of up to 88% depending on operating conditions.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate