Crown Bermuda 2 BSI069B and Crown Bermuda 2 BSI103B are two non-condensing boilers from the Crown Boiler Co. Bermuda 2 (BSIB) line. Published ratings: Crown Bermuda 2 BSI069B at 69 MBH input, 57 MBH DOE heating capacity and 82% AFUE; Crown Bermuda 2 BSI103B at 103 MBH input, 84 MBH DOE heating capacity and 82% AFUE. Crown Bermuda 2 BSI103B lists 34 MBH more input than Crown Bermuda 2 BSI069B (103 MBH against 69 MBH). Both list the same published AFUE of 82%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Crown Bermuda 2 BSI069B and Crown Bermuda 2 BSI103B
SpecificationCrown Bermuda 2 BSI069BCrown Bermuda 2 BSI103B
Input69 MBH103 MBH
Efficiency (AFUE)82 %82 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Boiler water volume5.1 gal6.5 gal
Dimensions (W × D × H)12-3/4" × 28" × 40-7/16"16" × 28" × 40-7/16"
VentingNatural draft into an approved chimneyNatural draft into an approved chimney
FuelNatural gas or LP gasNatural gas or LP gas
DOE heating capacity57 MBH84 MBH
AHRI net steam rating43 MBH63 MBH
Cast-iron sections34
Steamable water volume1.2 gal1.5 gal
Vent size4"5"
Approximate shipping weight350 lb420 lb

What actually separates them

Published ratings: the Crown Bermuda 2 BSI069B is rated 69 MBH input, 57 MBH DOE heating capacity and 82% AFUE; the Crown Bermuda 2 BSI103B is rated 103 MBH input, 84 MBH DOE heating capacity and 82% AFUE. Crown Bermuda 2 BSI103B lists 34 MBH more input than Crown Bermuda 2 BSI069B (103 MBH against 69 MBH). Both list the same published AFUE of 82%.

The boiler water content differs: the Crown Bermuda 2 BSI069B lists 5.1 gal, while the Crown Bermuda 2 BSI103B lists 6.5 gal. The dimensions differs: the Crown Bermuda 2 BSI069B lists 12-3/4" × 28" × 40-7/16", while the Crown Bermuda 2 BSI103B lists 16" × 28" × 40-7/16". The cast-iron sections differs: the Crown Bermuda 2 BSI069B lists 3, while the Crown Bermuda 2 BSI103B lists 4.

Both records print the same AFUE (82%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Natural draft into an approved chimney) and fuel (Natural gas or LP gas), per the cited sources.

Crown Boiler Co.

Crown Bermuda 2 BSI069B

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Crown Bermuda 2 BSI069B is the smallest Bermuda 2 size of the current cast-iron gas steam line: 69 MBH input, 57 MBH DOE heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, over 3 cast-iron sections with 5.1 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI103B

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Crown Bermuda 2 BSI103B is a 103 MBH mid-small size of the current cast-iron gas steam line: 103 MBH input, 84 MBH DOE heating capacity and a 63 MBH AHRI net steam rating (263 sq ft) at 82% AFUE, over 4 cast-iron sections with 6.5 gallons of boiler water.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Crown Bermuda 2 BSI103B lists 103 MBH, against 69 MBH on the Crown Bermuda 2 BSI069B, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 82%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate