Verdict in brief

Crown Bermuda 2 BSI103B and Crown Bermuda 2 BSI138B are two non-condensing boilers from the Crown Boiler Co. Bermuda 2 (BSIB) line. The Crown Bermuda 2 BSI103B is rated 103 MBH input, 84 MBH DOE heating capacity and 82% AFUE, and the Crown Bermuda 2 BSI138B is rated 138 MBH input, 113 MBH DOE heating capacity and 82% AFUE. Crown Bermuda 2 BSI138B lists 35 MBH more input than Crown Bermuda 2 BSI103B (138 MBH against 103 MBH). Both list the same published AFUE of 82%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Crown Bermuda 2 BSI103B and Crown Bermuda 2 BSI138B
SpecificationCrown Bermuda 2 BSI103BCrown Bermuda 2 BSI138B
Input103 MBH138 MBH
Efficiency (AFUE)82 %82 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Boiler water volume6.5 gal7.9 gal
Dimensions (W × D × H)16" × 28" × 40-7/16"19-1/4" × 28" × 40-7/16"
VentingNatural draft into an approved chimneyNatural draft into an approved chimney
FuelNatural gas or LP gasNatural gas or LP gas
DOE heating capacity84 MBH113 MBH
AHRI net steam rating63 MBH85 MBH
Cast-iron sections45
Steamable water volume1.5 gal1.8 gal
Vent size5"6"
Approximate shipping weight420 lb485 lb

What actually separates them

Published ratings: the Crown Bermuda 2 BSI103B is rated 103 MBH input, 84 MBH DOE heating capacity and 82% AFUE; the Crown Bermuda 2 BSI138B is rated 138 MBH input, 113 MBH DOE heating capacity and 82% AFUE. Crown Bermuda 2 BSI138B lists 35 MBH more input than Crown Bermuda 2 BSI103B (138 MBH against 103 MBH). Both list the same published AFUE of 82%.

The boiler water content differs: the Crown Bermuda 2 BSI103B lists 6.5 gal, while the Crown Bermuda 2 BSI138B lists 7.9 gal. The dimensions differs: the Crown Bermuda 2 BSI103B lists 16" × 28" × 40-7/16", while the Crown Bermuda 2 BSI138B lists 19-1/4" × 28" × 40-7/16". The cast-iron sections differs: the Crown Bermuda 2 BSI103B lists 4, while the Crown Bermuda 2 BSI138B lists 5.

Both records print the same AFUE (82%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Natural draft into an approved chimney) and fuel (Natural gas or LP gas), per the cited sources.

Crown Boiler Co.

Crown Bermuda 2 BSI103B

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Crown Bermuda 2 BSI103B is a 103 MBH mid-small size of the current cast-iron gas steam line: 103 MBH input, 84 MBH DOE heating capacity and a 63 MBH AHRI net steam rating (263 sq ft) at 82% AFUE, over 4 cast-iron sections with 6.5 gallons of boiler water.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Bermuda 2 BSI138B

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Crown Bermuda 2 BSI138B is a 138 MBH mid size of the current cast-iron gas steam line: 138 MBH input, 113 MBH DOE heating capacity and a 85 MBH AHRI net steam rating (354 sq ft) at 82% AFUE, over 5 cast-iron sections with 7.9 gallons of boiler water.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Crown Bermuda 2 BSI138B lists 138 MBH, against 103 MBH on the Crown Bermuda 2 BSI103B, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 82%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate