De Dietrich GT 123A vs GT 125A

Verdict in brief

The GT 123A and GT 125A are the three- and five-section sizes of the GT 120A residential boiler: 94 versus 144 MBH gas input, 80 versus 122 MBH output, and 302 versus 412 lb dry weight. Both share the same 85.5% gas / 88% oil AFUE, 1-1/4" supply and return connections and 5" vent, so the choice is the home's heat loss.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of De Dietrich GT 123A and De Dietrich GT 125A
SpecificationDe Dietrich GT 123ADe Dietrich GT 125A
CSA gas input94 MBH144 MBH
CSA output (gas-oil)80 MBH122 MBH
AFUE (as printed)Gas 85.5% / Oil 88%Gas 85.5% / Oil 88%
Cast-iron sections35
Heating supply / return1-1/4" threaded outlet / 1-1/4" threaded return1-1/4" threaded outlet / 1-1/4" threaded return
Boiler vent connection5 in5 in
Weight (dry)302 lb412 lb

What actually separates them

Both models are eutectic cast-iron three-pass boilers from the GT 120A line, documented together in the GT-120A brochure. The 123A is a three-section boiler with 94 MBH CSA gas input and 80 MBH output; the 125A is a five-section unit at 144 MBH input and 122 MBH output. Oil inputs are 0.65 and 1.00 GPH No. 2 fuel respectively.

The published efficiency is identical across the line: AFUE 85.5% on gas and 88% on oil. Connections are also shared — 1-1/4" threaded supply and return, a 5" vent connection for both sizes, and the same 60 psi ASME water rating and 86–194 °F operating range. The GT 120A is approved for direct-vent, Type L or Type B natural-draft venting.

The meaningful differences are capacity, physical size and weight: five sections and 412 lb for the 125A against three sections and 302 lb for the 123A, with water capacity rising from 5 to 7.9 gallons. A heat-loss calculation decides between them; the smaller boiler will modulate less on a load that needs the 125A's output, and the larger one is simply oversized if the load fits the 123A.

CurrentSold in Canada
Input
—
Output (max)
80 MBH
AFUE
Gas 85.5% / Oil 88%

The De Dietrich GT 123A is a 3-section eutectic cast-iron 3-pass boiler rated 94 MBH gas input / 80 MBH output (0.65 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.

Natural gasPropaneDHW: unknown
CurrentSold in Canada
Input
—
Output (max)
122 MBH
AFUE
Gas 85.5% / Oil 88%

The De Dietrich GT 125A is a 5-section eutectic cast-iron 3-pass boiler rated 144 MBH gas input / 122 MBH output (1 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.

Natural gasPropaneDHW: unknown

Frequently asked questions

Is there an efficiency difference between the GT 123A and GT 125A?

No. The GT 120A brochure prints the same AFUE for the line — 85.5% gas and 88% oil — for every size.

Do they use the same venting?

Both print a 5" boiler vent connection and are approved for direct-vent, Type L (gas-oil) or Type B (gas only) natural-draft venting.

Which size suits a small home?

That depends on the calculated heat loss. The 123A at 80 MBH output is the smallest GT 120A size; larger homes move up through the 124A and 125A to the 126A.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.