De Dietrich GT 124A vs GT 126A

Verdict in brief

The GT 124A and GT 126A bracket the GT 120A line: 115 versus 166 MBH gas input, 98 versus 141 MBH output, four versus six sections. The 126A is the only size in the line with a 6" vent connection; both keep the same 85.5% gas / 88% oil AFUE and 1-1/4" threaded supply and return.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of De Dietrich GT 124A and De Dietrich GT 126A
SpecificationDe Dietrich GT 124ADe Dietrich GT 126A
CSA gas input115 MBH166 MBH
CSA output (gas-oil)98 MBH141 MBH
AFUE (as printed)Gas 85.5% / Oil 88%Gas 85.5% / Oil 88%
Cast-iron sections46
Heating supply / return1-1/4" threaded outlet / 1-1/4" threaded return1-1/4" threaded outlet / 1-1/4" threaded return
Boiler vent connection5 in6 in
Weight (dry)357 lb470 lb

What actually separates them

The GT 124A is a four-section, 115 MBH input boiler producing 98 MBH; the GT 126A is the six-section top size at 166 MBH input and 141 MBH output. Oil inputs are 0.80 and 1.15 GPH. Both come with the same printed AFUE (85.5% gas / 88% oil), 60 psi ASME water rating and 230 °F maximum water temperature.

The installation difference to plan for is the vent: the brochure prints a 6" vent connection for the GT 126A against 5" for the 124A. Supply and return stay 1-1/4" threaded, and both models use the same direct-vent / Type L / Type B venting options. Dry weight rises from 357 lb to 470 lb and water capacity from 6.5 to 9.4 gallons.

For sizing, the 126A is the ceiling of the GT 120A line — above it the next step is the larger GT 220A family. A load that lands near 141 MBH output on a design day points to the 126A; a load comfortably under 98 MBH is served by the 124A without paying for unused capacity.

CurrentSold in Canada
Input
—
Output (max)
98 MBH
AFUE
Gas 85.5% / Oil 88%

The De Dietrich GT 124A is a 4-section eutectic cast-iron 3-pass boiler rated 115 MBH gas input / 98 MBH output (0.8 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.

Natural gasPropaneDHW: unknown
CurrentSold in Canada
Input
—
Output (max)
141 MBH
AFUE
Gas 85.5% / Oil 88%

The De Dietrich GT 126A is a 6-section eutectic cast-iron 3-pass boiler rated 166 MBH gas input / 141 MBH output (1.15 GPH on oil) at a printed AFUE of 85.5% gas / 88% oil, with 1-1/4" supply and return connections.

Natural gasPropaneDHW: unknown

Frequently asked questions

What is the largest GT 120A size?

The GT 126A: six sections, 166 MBH CSA gas input, 141 MBH output and a 6" vent connection, per the GT 120A brochure.

Does the GT 126A need a different vent?

It prints a 6" vent connection where the other GT 120A sizes print 5"; the approved venting categories (direct-vent, Type L or Type B) are the same.

Are the connections the same?

Yes — both models use 1-1/4" threaded heating supply and return connections per the brochure dimensions drawing.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate